Based on the technical specifications of both compressors, it is not recommended to replace the burnt-out compressor (Jiaxipera N1113Y) with the second one (ACC HTK70AA).
Here is the technical comparison:
While both compressors use the same refrigerant (R600a) and voltage (220-240V), the ACC HTK70AA is significantly weaker than the original Jiaxipera.
If you install it, the following problems will occur:
You should look for a replacement compressor that has a cooling capacity of around 150–160 Watts or a displacement of 8.9 cm³ (equivalent to 1/6 HP). Using the 1/8 HP compressor (the ACC model) will likely result in a failed repair.
Focus Keyphrase: Technical analysis of Jiaxipera N1113Y and ACC HTK70AA compressor replacement compatibility
SEO Title: Mbsmpro.com, Compressor, Jiaxipera N1113Y, ACC HTK70AA, 1/6 hp, 1/8 hp, R600a, 220-240V, Cooling, LBP
Meta Description: Detailed technical review of the Jiaxipera N1113Y and ACC HTK70AA compressors. Learn why cooling capacity and displacement matter more than just the refrigerant type when performing a replacement.
Slug: jiaxipera-n1113y-vs-acc-htk70aa-compressor-technical-specifications
Tags: Jiaxipera N1113Y, ACC HTK70AA, R600a, Compressor, 1/6 hp, 1/8 hp, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GL90AA, HTK80AA, GVY66AA, EMT43HDP, NLE11KK, QP91Y, Wanbao ETB80Y, Embraco EMT43HDP, Secop NLE11KK
Excerpt: Selecting the right compressor for a refrigeration system is critical for long-term performance and energy efficiency. When replacing a Jiaxipera N1113Y, simply matching the refrigerant type is not enough. This guide breaks down the technical differences between the N1113Y and the ACC HTK70AA, providing the essential data for professional technicians and refrigeration engineers.
In the field of refrigeration, a compressor is the heart of the system. For an expert technician, replacing a unit isn’t just about finding a motor that fits the mounting bracket; it is a calculation of thermal dynamics. A common question arises when a Jiaxipera N1113Y fails: Can an ACC HTK70AA serve as a reliable substitute?
The short answer is no. To understand why, we must look at the displacement and the cooling capacity (Watts). The Jiaxipera N1113Y is a powerhouse in its class, designed for medium-to-large domestic refrigerators. It features a displacement of 8.9 cm³ and delivers approximately 154 Watts of cooling at Low Back Pressure (LBP) conditions.
In contrast, the ACC HTK70AA is a smaller unit. With a displacement of only 6.64 cm³, it produces around 117 Watts. When an undersized compressor like the HTK70AA is installed in a system designed for a 154W load, the compressor will run continuously, overheat, and eventually experience mechanical failure or winding burnout.
| Feature | Jiaxipera N1113Y | ACC HTK70AA | Impact of Difference |
| Displacement | 8.9 cm³ | 6.64 cm³ | Lower volume per stroke |
| Cooling Capacity | 154 W (~1/6 HP) | 117 W (~1/8 HP) | 24% loss in cooling power |
| Current (LRA) | ~7.5 A | ~6.1 A | Different torque characteristics |
| Efficiency (COP) | High Efficiency | Standard Efficiency | Increased energy consumption |
When you install a 1/8 HP compressor where a 1/6 HP unit is required, the internal pressures of the refrigeration cycle change. The suction pressure will remain higher than intended because the smaller piston cannot evacuate the evaporator quickly enough. This leads to poor frost patterns and higher cabinet temperatures, especially during high ambient summer conditions.
| Model | Jiaxipera N1113Y |
| Utilisation (mbp/hbp/lbp) | LBP (Low Back Pressure) |
| Domaine (Freezing/Cooling) | Freezing and Deep Cooling |
| Oil Type and quantity | Mineral/PAG (check label) 180ml |
| Horsepower (HP) | 1/6 HP |
| Refrigerant Type | R600a (Isobutane) |
| Power Supply | 220-240V ~ 50Hz |
| Cooling Capacity BTU | ~525 BTU/h |
| Motor Type | RSIR / RSCR |
| Displacement | 8.9 cm³ |
| Winding Material | Copper/Aluminum Alloy (Model Dependent) |
| Pression Charge | Low Pressure Side |
| Capillary | 0.026 to 0.031 inch (standard) |
| Refrigerator Type | No-Frost / Double Door 300L-400L |
| Temperature Function | -35°C to -15°C |
| With fan or no | Usually Static (No fan required) |
| Commercial or no | Domestic / Light Commercial |
| Amperage in function | 0.7 A – 0.9 A |
| LRA (Locked Rotor Amps) | 7.5 A |
| Type of relay | PTC Relay |
| Capacitor | 4µF to 5µF (Optional for RSCR) |
5 Recommended Replacements (Same Gas: R600a)
5 Recommended Replacements (Other Gas: R134a – Requires System Flush)
Question: If I have a 350-liter fridge, will the ACC HTK70AA work?
Answer: No. A 350-liter refrigerator typically requires the 154W capacity of the Jiaxipera N1113Y (1/6 HP). The ACC HTK70AA (1/8 HP) is designed for smaller units (around 150-220 liters). Using it will lead to continuous running and premature failure.