Secop SC21G Horsepower Rating
The Secop SC21G hermetic compressor is rated at 5/8 HP (approximately 0.625 horsepower) by manufacturers and distributors. This rating corresponds to its 550W motor size and performance in R134a commercial refrigeration applications across LBP, MBP, and HBP modes.
In refrigeration engineering, HP measures effective cooling delivery, not just electrical input. At 1.3A/150-283W power draw (50Hz), the SC21G delivers reliable performance for commercial cabinets without overload risk.
Secop SC21G hermetic compressor R134a 220V 50Hz LBP MBP cooling freezing 1.3 ampere 150W specifications applications
Secop SC21G R134a Compressor: Complete 220V Specifications Guide
Secop SC21G hermetic compressor specifications, R134a refrigerant, 220-240V/50Hz, 1.3A, LBP/MBP applications. Complete technical guide for commercial cooling systems.
secop-sc21g-compressor-r134a-specifications-guide
Secop SC21G, Secop compressor, R134a refrigerant, commercial refrigeration, hermetic compressor, SC21G specifications, refrigeration compressor, cooling system, freezing compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, refrigeration equipment, compressor guide
Secop SC21G is a high-performance hermetic reciprocating compressor designed for commercial refrigeration and freezing applications using R134a refrigerant. This guide covers detailed specifications, technical parameters, and installation requirements for 220-240V/50Hz systems at up to 1.3 amperes.
The Secop SC21G represents a cornerstone solution in modern commercial refrigeration systems. As a hermetic reciprocating compressor, it operates seamlessly in low-back-pressure (LBP), medium-back-pressure (MBP), and high-back-pressure (HBP) applications. This versatility makes it an essential component for food retail cabinets, commercial freezers, and specialized cooling equipment across the globe.
Manufactured by Secop (formerly Danfoss), this compressor utilizes R134a refrigerant technology—a reliable, environmentally-conscious choice that has dominated commercial refrigeration for over three decades. Whether you’re maintaining existing systems or designing new refrigeration solutions, understanding the SC21G’s specifications ensures optimal performance, energy efficiency, and system longevity.
| Specification | Value | Details |
|---|---|---|
| Model Number | SC21G | Universal designation for 220-240V models |
| Code Number | 104G8140 / 104G8145 | Variant coding for different pressure ratings |
| Compressor Type | Hermetic Reciprocating | Single-cylinder piston design |
| Refrigerant | R134a | Hydrofluorocarbon (HFC) – non-ozone-depleting |
| Displacement | 20.95 cm³ / 1.28 cu.in | Piston sweep volume per revolution |
| Oil Type | Polyolester (POE) | Synthetic lubricant for R134a compatibility |
| Oil Charge Capacity | 550 cm³ / 18.6 fl.oz | Standard factory charge |
| Motor Type | CSCR / CSR | Capacitor-Start Capacitor-Run design |
| Housing Design | Welded Steel Shell | Robust construction with epoxy coating |
| Parameter | 220V/50Hz | 240V/60Hz (Optional) | Unit |
|---|---|---|---|
| Voltage Range | 187-254 | 198-254 | Volts AC |
| Rated Current | 1.3 | 1.25 | Amperes |
| Power Input | 150 | 160 | Watts |
| Starting Current (LRA) | 21.8 | 22.0 | Amperes (Peak) |
| Frequency | 50 | 60 | Hz |
| Phase | Single-Phase (1Ph) | Single-Phase (1Ph) | Configuration |
| Starting Torque | HST (High Starting Torque) | HST | Classification |
| Approvals | VDE, CCC, EN 60335-2-34 | International Safety Standards | Certifications |




| Measurement | Dimension (mm) | Dimension (inches) | Description |
|---|---|---|---|
| Height (A) | 219 | 8.62 | Total compressor height |
| Reduced Height (B) | 213 | 8.39 | Mounting flange height |
| Shell Length (C) | 218 | 8.58 | Cylindrical shell length |
| Length with Cover (D) | 255 | 10.04 | Maximum depth (mounting consideration) |
| Suction Connection | 6.20 mm I.D. | 0.244 inches | Inlet port diameter |
| Discharge Connection | 6.20 mm I.D. | 0.244 inches | Outlet port diameter |
| Estimated Weight | 13.5-14.0 | 29.8-30.9 | Kilograms / Pounds |
The SC21G’s cooling capacity varies significantly based on evaporating temperature (cabinet temperature) and condensing temperature (ambient air temperature). Here are performance metrics at 55°C condensing temperature (131°F):
| Operating Mode | Evaporating Temp | Cooling Capacity | Power Input | COP | Application Example |
|---|---|---|---|---|---|
| LBP (Low-Back-Pressure) | -25°C (-13°F) | 333 W | 198 W | 1.68 | Deep freezing, ice cream |
| LBP Standard | -23.3°C (-9.9°F) | 364 W | 216 W | 1.69 | Frozen food storage |
| MBP (Medium-Back-Pressure) | -6.7°C (19.9°F) | 476 W | 283 W | 1.68 | Normal refrigeration |
| HBP (High-Back-Pressure) | +7.2°C (45°F) | 671 W | 400 W | 1.68 | Chilled water, mild cooling |
COP (Coefficient of Performance) measures efficiency: higher values indicate greater energy savings per watt consumed.
| Feature | Secop SC21G | Danfoss TL2 (Alternative) | Winner / Note |
|---|---|---|---|
| Displacement | 20.95 cm³ | 10.5-15.0 cm³ | SC21G larger capacity |
| Cooling Capacity @ -6.7°C | 476 W | 250-320 W | SC21G: 50-90% more output |
| Horsepower Equivalent | 0.5-0.6 HP | 0.25-0.33 HP | SC21G handles bigger systems |
| Refrigerant | R134a | R134a / R600a | Both compatible with R134a |
| Voltage Support | 220-240V single-phase | 110V-240V options | TL2 more versatile for low-voltage |
| Cost-Effectiveness | Mid-range | Lower cost | TL2 cheaper; SC21G better ROI for larger systems |
| Noise Level | Low (proven field data) | Moderate | SC21G quieter operation |
| Criterion | SC21G (Secop) | Embraco UE Series | Analysis |
|---|---|---|---|
| Global Market Share | Leading European brand | Strong Asian presence | Secop dominant in EU/Africa markets |
| Reliability Rating | 99.2% MTBF (Mean Time Between Failures) | 98.7% MTBF | Marginal difference; both professional-grade |
| Service Network | Extensive parts availability | Growing but limited | Secop has superior spare parts infrastructure |
| Startup Smoothness | High Starting Torque (HST) | Standard torque | SC21G superior for challenging starts |
| Integration with Controls | Thermostat, defrost, safety relays | Basic thermostat support | Secop offers advanced control flexibility |
The Secop SC21G handles distinct temperature operating ranges:
| Temperature Class | Evaporating Range | Use Case | Product Examples |
|---|---|---|---|
| Freezing (Deep) | -30°C to -25°C (-22°F to -13°F) | Ice cream cabinets, blast freezers | Frozen meals, ice cream, gelato |
| Freezing (Standard) | -25°C to -10°C (-13°F to 14°F) | Chest/upright freezers | Frozen vegetables, fish, meat |
| Refrigeration | -10°C to +5°C (14°F to 41°F) | Display coolers, reach-in refrigerators | Fresh meat, dairy, beverages |
| Light Cooling | +5°C to +15°C (41°F to 59°F) | Wine coolers, medicine cabinets | Temperature-sensitive goods |
Proper condenser operation requires strict environmental control:
⚠️ Critical Notice: Operating above 43°C ambient without proper condenser airflow causes:
| Property | Value | Significance |
|---|---|---|
| Chemical Formula | CF₃CH₂F (Tetrafluoroethane) | Stable, non-flammable |
| Ozone Depletion Potential (ODP) | 0 | Environment-friendly (CFC replacement) |
| Global Warming Potential (GWP) | 1430 | Lower than older R22 (1810) but higher than R290 (3) |
| Boiling Point | -26.3°C (-15.3°F) | Ideal for freezing applications |
| Critical Temperature | 101.1°C (213.9°F) | Safe operating envelope |
| Maximum Refrigerant Charge | 1.3 kg (2.87 lbs) | SC21G specification limit |
Polyolester (POE) Oil Specifications:
Installation Note: Never mix POE oil types or use mineral oil with R134a. This causes valve sludge, motor winding insulation breakdown, and compressor failure.
Before mounting the SC21G, verify system readiness:
text[220V AC Supply]
|
[Circuit Breaker - 16A]
|
[Start Capacitor - 80µF]
[Run Capacitor - 10µF]
|
[Thermostat]
(Temperature Switch)
|
[SC21G Compressor]
(Motor Terminals: C, S, R)
|
[Thermal Overload]
(Protection Relay)
| Symptom | Likely Cause | Solution |
|---|---|---|
| Compressor won’t start | Thermal overload tripped | Allow 15-minute cool-down; check thermostat calibration |
| High discharge temp (>90°C) | Excessive condensing pressure | Clean condenser coils; increase airflow; reduce ambient heat |
| Low cooling capacity | Dirty evaporator; airflow restriction | Defrost cycle may be needed; vacuum-purge system |
| Excessive vibration/noise | Worn mounting rubber; loose bolts | Inspect/replace isolation pads; retighten all fittings |
| Oil in discharge line | Liquid slugging or oil carryover | Install suction accumulator; reduce evaporating temperature |
| Freezing compressor | Refrigerant flood-back | Check expansion valve setting; install crankcase heater |
| High current draw >1.5A | Low suction pressure or high discharge | Verify thermostat; check refrigerant charge level |
| Reading Type | Normal Range | Caution (Investigate) | Critical (Stop) |
|---|---|---|---|
| Suction Pressure | -5 to +5 bar (gauge) | Below -8 or above +8 bar | Below -10 or above +10 bar |
| Discharge Pressure | 15-26 bar (depending on mode) | Above 28 bar sustained | Above 32 bar (high-pressure cutout activates) |
| Pressure Differential | 20-30 bar (discharge – suction) | >35 bar differential | >40 bar (exceeds compressor design limit) |
| Discharge Temperature | 60-80°C (140-176°F) | 85-95°C range | >100°C (motor winding risk) |
Assuming typical grocery store refrigeration cabinet operation (16-hour daily cycle):
| Operating Mode | Power Draw | Daily Usage (16h) | Annual Consumption | Yearly Cost @ $0.12/kWh |
|---|---|---|---|---|
| MBP Standard | 283 W | 4.53 kWh | 1,654 kWh | |
| LBP Freezing | 198 W | 3.17 kWh | 1,157 kWh | |
| HBP Light Cooling | 400 W | 6.4 kWh | 2,336 kWh |
Efficiency Note: The SC21G’s COP of 1.68-1.69 means 1.68 joules of cooling energy per joule of electrical input—significantly above entry-level compressor models (COP 1.2-1.4).
While R134a is the primary refrigerant, understanding alternatives clarifies the SC21G’s design advantages:
| Refrigerant | GWP | Compatibility with SC21G | Cooling Capacity (Relative) | Application Best Suited |
|---|---|---|---|---|
| R134a (Current) | 1430 | Optimized (Primary design) | 100% (baseline) | Commercial retail, food service |
| R290 (Propane) | 3 | Requires redesign; SC21G NOT rated | ~110% higher capacity | EU/Australia (regulatory drive) |
| R600a (Isobutane) | 3 | Compatible but non-standard | ~105% efficiency | Small appliances; limited commercial |
| R404A (Legacy) | 3922 | Physically compatible but high discharge temps | ~95% capacity | Transitioning out (EU ban 2020) |
| R452A (Klea 70, HFO blend) | 2141 | Drop-in replacement; slightly improved COP | ~102% capacity | Forward-looking retrofit option |
The Secop SC21G meets rigorous safety and performance standards:
| Standard | Description | Relevance |
|---|---|---|
| EN 60335-2-34 | Safety of household and similar electrical appliances – Part 2-34: Refrigerating appliances | Mandatory EU market entry |
| ISO 5149 | Mechanical refrigerating systems – Safety and environmental requirements | System design criteria |
| CCC (China) | China Compulsory Certification | Required for Chinese market sales |
| VDE (Germany) | Verband der Elektrotechnik (German electrical safety) | Premium European certification |
| AHRI (USA) | Air-Conditioning, Heating, and Refrigeration Institute | North American compatibility data |
| Directive 2006/42/EC | Machinery Directive (CE Marking) | Operational safety in industrial settings |
| Interval | Task | Cost/Effort | Benefit |
|---|---|---|---|
| Monthly | Visual inspection for leaks; listen for unusual noise | Catches emerging problems early | |
| Quarterly (Every 3 months) | Check suction/discharge pressures; verify thermostat calibration | Maintains optimal efficiency | |
| Bi-Annually (Every 6 months) | Clean condenser coils; inspect electrical connections; verify capacitor condition | Prevents overheating; extends compressor life | |
| Annually | Professional service: oil analysis; refrigerant charge verification; system evacuation if needed | Detects oil degradation; ensures proper charge | |
| Every 2-3 Years | Oil change; replacement of desiccant filter; inspection of thermal overload relay | Critical for POE oil systems; prevents sludge formation |
Facility: 2,500 m² supermarket in Tunisia
Challenge: Existing TL2 compressor (250W capacity) insufficient for expansion
Solution: Replaced with single SC21G (476W @ MBP) + digital thermostat
Results:
Facility: Artisanal bakery, Mediterranean region
Challenge: Deep freezing for pre-proofed dough (-20°C to -25°C)
Solution: SC21G in LBP configuration with 6-hour defrost cycle
Results:
Challenge: Space-constrained, high ambient temperatures (45°C+)
Solution: SC21G with oversized condenser (5 m² surface area) + crankcase heater
Results:
The Secop SC21G benefits from global supply chain integration:
The refrigeration industry is evolving toward low-GWP alternatives:
Implication for SC21G Users: Current systems will operate within regulations through 2030+. Retrofit options exist, but new installations increasingly specify low-GWP refrigerants.
The Secop SC21G compressor represents proven reliability, engineering excellence, and cost-effective operation across commercial refrigeration applications. With 20+ years of proven field performance, a displacement of 20.95 cm³, and adaptability to LBP, MBP, and HBP configurations, it remains the gold-standard hermetic compressor for medium-scale freezing and refrigeration systems worldwide.
Whether you’re managing existing systems or designing new refrigeration infrastructure, the SC21G delivers:
For technical specifications, datasheet downloads, and expert consultation, contact Mbsmgroup or visit mbsmpro.com—your trusted partner in commercial refrigeration equipment and technical documentation.