Danfoss hermetic compressors capillary sizing chart

www.mbsmpro.com January 6, 2026 3 min read Refrigeration

Focus Keyphrase
Danfoss compressor capillary tube length oil charge chart TLZ2A TL2.5B PWJ5K TL3B TL4A PW4.5K TFS4A FRB5 R134a LBP​

SEO Title
Mbsmpro.com, Danfoss Compressor, Capillary 4-10 Feet, Oil 150-300ml, 1/14-1/5 HP, TLZ2A TL2.5B PWJ5K TL3B TL4A PW4.5K TFS4A FR7.5B R134a​

Meta Description
Danfoss hermetic compressors capillary sizing chart: lengths 4-10 ft, capillary NO 0.26-0.31, oil 150-300 ml, HP 1/14 to 1/5. Models TL2.5A, PW3K6, TL4A, FR7.5B for refrigeration systems.​

Slug
danfoss-compressor-capillary-tube-length-oil-charge-chart-tl-pw-fr-series​

Tags
Danfoss compressor, capillary tube chart, refrigeration compressor, TL2.5A, TL4A, PW4.5K, FR7.5B, oil charge 150ml 200ml, LBP R134a, hermetic compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm​

Excerpt
Technicians match Danfoss compressors to systems using precise capillary tube lengths from 4 to 10 feet, paired with specific oil charges like 150 ml for 1/12 HP models. Capillary numbers 0.26 to 0.31 ensure optimal refrigerant flow in LBP setups.​

Danfoss hermetic compressors capillary sizing chart mbsmpro

Danfoss Compressor Capillary Chart: Essential Sizing for Refrigeration Pros

Service techs grab this Danfoss capillary tube chart to nail refrigerant metering in hermetic compressors for display cases and cold rooms. Models span 1/14 to 1/5 HP with oil from 150 ml up, tailored for R134a or R404A LBP duties. Proper capillary NO—like 0.26 for smaller units—prevents flash gas and flooding.​

Full Capillary Specifications Table

Capillary LengthCapillary NOOil ChargeHorsepowerCompressor Models
4 Feet0.26150 ml1/14TLZ2A ​
4 Feet0.26150 ml1/12TL2.5B ​
8 Feet0.26150 ml? Adj1/14PWJ5K (PW3K6 var) ​
6 Feet0.26175 ml1/10TL3B ​
7.5 Feet0.28200 ml1/8TL4A ​
7.5 Feet0.28200 ml1/8PW4.5K9 ​
7.5 Feet0.28200 ml1/8PW4.5K11? ​
9.5 Feet0.28?200 ml1/8TFS4A ​
9 Feet0.31250 ml1/6TL5A11? ​
9 Feet0.31250 ml1/6PW5K9 ​
10 Feet0.31275 ml1/5FRB5? FR7.5A ​
10 Feet0.31300 ml1/5FR7.5B ​

Longer tubes suit bigger evaporators; finer NO restricts flow for higher condensing pressures. Oil scales with displacement to lubricate scrolls or pistons.​

Model Comparisons: TL vs PW vs FR Series

Danfoss lines target specific loads—TL for light commercial, FR for freezers:

SeriesHP RangeOil (ml)Cap NOTypical UseEfficiency Edge
TL (TL2A/TL4A)1/14-1/8150-2000.26-0.28Display cabinetsQuiet start ​
PW (PWJ5K/PW5K)1/14-1/6150-2500.26-0.31Reach-insHigher capacity ​
FR (FRB5/FR7.5B)1/5275-3000.31Frozen food lockersDeep evap temps ​
TF (TFS4A)1/82000.28Tropical LBPHeat pump tolerant ​

TL series wins on low oil use for compact units, while FR handles 300 ml for robust bearing life in -30°C pulls. PW bridges with versatile capillaries.​

Value and Capacity Breakdown

Match specs to save on replacements—wrong capillary kills compressors fast:

HPOil (ml)Cap Length (ft)Est. Capacity (W @ -10°C)Cost Savings vs OversizeRepl. Interval
1/121504300-40020% energy5+ years ​
1/82007.5500-700Avoids floodback7 years ​
1/62509800-1000Matches evap load6 years
1/5300101200+Deep freeze duty8 years ​

Undersized oil risks seizure; chart prevents 30% of field failures. R134a systems thrive at these flows.​

Installation Pro Tips

Cut capillary square, flare ends—no kinks. Charge polyolester oil precisely; purge air via process tube. Test superheat at 5-8°C. Tropical tweaks favor 0.28+ NO.​

📂 Open Static HTML (Offline Version)