Focus Keyphrase: Konor GPY16AF R134a Compressor Technical Specifications and Professional Replacement Guide
SEO Title: Mbsmpro.com, Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP, 220-240V 50Hz, Freezing, Technical Data
Meta Description: Explore the full technical breakdown of the Konor GPY16AF compressor. This 1/2 HP R134a unit is ideal for LBP freezing applications. Includes specs, wiring, and cross-reference.
Slug: konor-gpy16af-compressor-r134a-lbp-specs
Tags: Konor, GPY16AF, R134a, 1/2 HP, LBP, Compressor, Freezing, Refrigeration, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm
Excerpt: The Konor GPY16AF is a robust hermetic reciprocating compressor engineered for low back pressure applications using R134a refrigerant. With a displacement of 16.2 cm³, this 1/2 HP unit is a staple in commercial freezers and large refrigerators. This guide provides detailed technical data, wiring diagrams, and professional cross-reference options for field technicians.
The refrigeration industry relies on precision and durability, and the Konor GPY series stands out as a high-performance solution for low-temperature requirements. Specifically, the GPY16AF model is a hermetic reciprocating compressor designed to meet the rigorous demands of deep-freezing units. Utilizing R134a refrigerant, this compressor balances thermal efficiency with mechanical reliability, making it a preferred choice for large-capacity domestic appliances and light commercial units.
| Feature | Specification |
| Model | GPY16AF |
| Utilisation | LBP (Low Back Pressure) |
| Domaine | Freezing / Deep Cold Storage |
| Oil Type and Quantity | POE Oil / 350 ml |
| Horsepower (HP) | 1/2 HP |
| Refrigerant Type | R134a |
| Power Supply | 220-240V / 50Hz / 1 Phase |
| Cooling Capacity BTU | Approximately 1540 BTU/h (at -23.3°C ASHRAE) |
| Motor Type | CSIR (Capacitor Start – Induction Run) |
| Displacement | 16.2 cm³ |
| Winding Material | High-Grade Copper |
| Pressure Charge | Suction: 0.5 – 5 PSI (Normal LBP range) |
| Capillary Recommendation | 0.042″ x 10ft (Variable per load) |
| Application Units | Large Chest Freezers, Vertical Freezers |
| Temperature Function | -35°C to -15°C |
| Fan Requirement | Static or Forced Air (Fan recommended for high ambient) |
| Commercial Use | Yes, Light Commercial / Domestic |
| Amperage (FLA) | 2.5 A – 2.8 A |
| LRA (Locked Rotor Amps) | 17 A |
| Type of Relay | Potential or Electromagnetic Relay |
| Capacitor Requirement | Starting Capacitor (approx. 60-80 µF) |
From a field worker’s perspective, the GPY16AF is recognized for its high volumetric efficiency. The 16.2 cm³ displacement allows for rapid pulldown times in large evaporation systems. Unlike smaller residential compressors, this unit features reinforced copper windings that handle the high torque required during the startup phase of a heavy refrigeration cycle.
When comparing the Konor GPY16AF to other market leaders, we notice a distinct advantage in its thermal management. The internal motor protection is calibrated to prevent burnout during voltage fluctuations, a common issue in many regions.
Finding an exact match for a compressor in the field is not always possible. Below are professional alternatives categorized by refrigerant type.
| Brand | Model | HP | Displacement |
| Embraco | FFI12HBX | 1/2 HP | 11.14 cm³ |
| Danfoss/Secop | SC15G | 1/2 HP | 15.28 cm³ |
| Tecumseh | AE2415Y | 1/2 HP | 12.50 cm³ |
| Kulthorn | AE7440Y | 1/2 HP | 14.50 cm³ |
| Huayi | HYE15YG | 1/2 HP | 15.00 cm³ |
| Brand | Model | Gas Type | Note |
| Embraco | NEK2150GK | R404a | Requires TXV adjustment |
| Secop | SC18CL | R404a | High cooling capacity |
| Jiaxipera | VNX1116Y | R600a | High efficiency / Low noise |
| Nidec | GPY12RAA | R600a | Eco-friendly alternative |
| Danfoss | NL11MF | R134a/R404a | Multi-refrigerant capable |
codeText
[Neutral] ---------------- (Common Terminal)
|
[Winding]
|
[Live] -----[Overload]----[Relay]---- (Main Winding)
|
[Start Cap]
|
(Start Winding)
Notice: Always verify the starting capacitor value on the specific unit label before replacement. Using an undersized capacitor can lead to starting failures, while an oversized one may overheat the start winding.