Jiaxipera JM1080Y Compressor 1/8 hp R600a, capillary 0.028 2.5m

Jiaxipera JM1080y, 1/6 hp+, 143w, r600a, capillary 0.028 inch diameter with a length of 2.5 meters mbsmpro

Mbsmpro.com, Compressor, JM1080Y, 1/8 hp, Jiaxipera, Cooling, R600a, 100 W, 0.6 A, 1Ph 220–240V 50Hz, LBP, RSCR, -35°C to -10°C, cooling or freezing

Jiaxipera JM1080Y Technical Specifications

This compressor is a high-efficiency model designed for R600a refrigerant and Low Back Pressure (LBP) applications.

Compressor Performance Data

  • Horsepower (HP): Rated at approximately 1/8 HP (or 1/8+ HP).
  • Cooling Capacity: Reaches up to 100 Watts (approximately 341 BTU/h) according to ASHRAE standards.
  • Displacement: 6.0 $cm^3$.
  • Refrigerant Type: R600a (Isobutane).

Recommended Capillary Tube Sizes

To achieve the best performance in domestic refrigeration units, use the following specifications:

  • Primary Option: 0.031 inch (0.8 mm) diameter with a length of 3 meters.
  • Secondary Option: 0.028 inch (0.7 mm) diameter with a length of 2.5 meters.

Technical Installation Notes

  • Precision Charging: Because R600a is used, the system must be charged strictly by weight (in grams) as indicated on the appliance’s data plate.
  • Sensitivity: This refrigerant is highly sensitive to even minor deviations in gas volume.
  • Vacuum Process: A thorough vacuum (20–30 minutes) is mandatory to ensure the system is completely free of air and moisture before charging.

The refrigeration industry relies on precision components to maintain efficiency and food safety. Among these, the Jiaxipera JM1080Y stands out as a high-performance, hermetic reciprocating compressor engineered for modern domestic appliances. Designed for low-back-pressure (LBP) applications, this unit is commonly found in energy-efficient refrigerators and freezers where quiet operation and low energy consumption are paramount.

Operating on R600a (Isobutane), the JM1080Y reflects the global shift toward environmentally friendly refrigerants with low global warming potential. Its design incorporates a robust motor and optimized internal mechanics to ensure longevity and consistent cooling capacity even under varying thermal loads.


Technical Specifications: Jiaxipera JM1080Y

Feature Specification
Model JM1080Y
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing and Cooling
Cooling wattage at -23.3°C 100 W
Cubic feet (approx. cooling capacity) 6.5 to 8.5 cu. ft.
Litres (approx. cooling capacity) 185 to 240 Liters
Kcal/h 86 Kcal/h
Oil Type and Quantity Mineral Oil / 180 ml
Horsepower (HP) 1/8 hp
Refrigerant Type R600a
Power Supply 220–240V / 50Hz
Cooling Capacity BTU/h 341 BTU/h
Motor Type RSCR (Resistance Start – Capacitor Run)
Displacement 6.2 cm³
Winding Material Copper
Pression Charge Low Pressure
Capillary (Suggested) 0.026″ – 0.031″
Refrigerator Models Bosch, Haier, Samsung, Beko, Hisense
Temperature Function -35°C to -10°C
With fan or no Static (Natural cooling)
Commercial or no No (Domestic / Household)
Amperage in function 0.55 A – 0.6 A
LRA (Locked Rotor Amps) 4.6 A
Type of relay PTC Starter
Capacitor Value 2.5 µF / 450V
Country of Origin China

Efficiency Metrics (COP) & Performance Data

The coefficient of performance (COP) is a critical indicator of how much cooling work the compressor does relative to the electrical energy it consumes.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 58 51 1.14
-30 76 60 1.27
-23.3 (Standard) 100 68 1.47
-20 118 74 1.59
-15 146 82 1.78
-10 180 92 1.96

Comparison: JM1080Y vs. Industry Standard 1/10 HP Units

While many 1080 models are rated at 1/10 HP, the JM1080Y is frequently categorized as a 1/8 HP unit due to its higher displacement (6.2 cm³) compared to the standard 5.5 cm³ found in models like the NE1080Y. This extra displacement provides a higher cooling reserve, making it more resilient in high-ambient temperature conditions.


Replacement Cross-Reference

5 Replacements (Same Gas: R600a)

  • Embraco: EMX32CLC
  • Secop (Danfoss): TLES5.7KK.3
  • Huayi: HYE55Y
  • Donper: A90CY
  • LG: CMA057LBJH

5 Replacements (Other Gas: R134a)

Note: Converting systems between refrigerants requires a total oil flush and system cleaning.

  • Jiaxipera: ND1080Y
  • Embraco: EMT32HLP
  • Secop: TLS5F
  • Cubigel: GL45AA
  • Tecumseh: THG1335YS

Expert Engineering Advice & Notice

  1. Refrigerant Safety: R600a is highly flammable. Always ensure there are no ignition sources in the work area and use a vacuum pump specifically rated for hydrocarbons.
  2. Vacuum & Moisture: A deep vacuum of 500 microns or less is mandatory. Mineral oil in R600a systems is sensitive to moisture, which can cause internal acid formation.
  3. Capillary Selection: If replacing a compressor with a different brand, always verify the capillary tube size. A mismatch can lead to liquid slugging or poor evaporator utilization.
  4. Static Cooling: This compressor is designed for static cooling. Do not enclose it in a tight space without adequate airflow, as overheating will drastically reduce the lifespan of the motor windings.

Focus Keyphrase: Jiaxipera JM1080Y Compressor 1/8 hp R600a

SEO Title: Mbsmpro.com, Jiaxipera JM1080Y, 1/8 HP, R600a Refrigerator Compressor

Meta Description: Detailed technical data for the Jiaxipera JM1080Y compressor. 1/8 HP, 100W cooling capacity, R600a refrigerant. Includes wiring, COP tables, and compatible replacements for LBP applications.

Slug: jiaxipera-jm1080y-compressor-1-8-hp-r600a-specs

Add Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Jiaxipera, JM1080Y, R600a Compressor, 1/8 HP Compressor, Refrigerator Repair, EMX32CLC replacement, TLES5.7KK.3, HYE55Y, LBP Compressor, Cooling Capacity 100W.

Excerpt: The Jiaxipera JM1080Y is a high-performance 1/8 hp compressor specifically designed for R600a refrigerant in domestic LBP applications. With a cooling capacity of 100W and a displacement of 6.2 cm³, it provides a quiet, energy-efficient solution for modern refrigerators. This guide covers technical data, performance metrics, and professional field advice for technicians.

Jiaxipera JM1080y, 1/6 hp+, 143w, r600a, capillary 0.028 inch diameter with a length of 2.5 meters mbsmpro



Huayi HYB60MGU Compressor 1/7 HP R600a LBP

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro

Focus keyphrase: Huayi HYB60MGU Compressor 1/7 HP R600a LBP Technical Specifications Wiring Diagram and Professional Replacement Guide for Domestic Refrigeration Systems

SEO Title: Mbsmpro.com, Compressor, Huayi, HYB60MGU, 1/7 hp, R600a, 110 W, 0.55 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, cooling or freezing

Meta Description: Technical datasheet for the Huayi HYB60MGU compressor. Explore its 1/7 HP capacity, R600a efficiency, electrical wiring schemas, and professional cross-reference replacements.

Slug: huayi-hyb60mgu-compressor-r600a-1-7hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYB60MGU, R600a, 1/7 HP, LBP, Compressor Replacement, EMT45HDR, TLES5.7KK.3, T1112Y, A60CY, ETA60, GL60AA, EMI45HER, TLS5F, B30H

Excerpt: The Huayi HYB60MGU is a high-efficiency hermetic reciprocating compressor specifically engineered for Low Back Pressure (LBP) applications. Operating on the eco-friendly R600a refrigerant, this 1/7 HP unit is a primary component in modern household refrigerators. This guide provides an in-depth technical analysis, electrical wiring configurations, and reliable replacement alternatives for field engineers.


The Engineering Behind the Huayi HYB60MGU: A Technical Standard in R600a Cooling

In the contemporary landscape of domestic refrigeration, the Huayi HYB60MGU represents a cornerstone of energy-efficient design. As a professional who has spent years troubleshooting and installing these units, it is clear that Huayi has optimized the HYB series to meet the rigorous European and international standards for low-temperature performance.

This compressor is a hermetic reciprocating type, designed for Low Back Pressure (LBP) cycles. Its integration of R600a (isobutane) not only aligns with global environmental mandates but also provides superior thermodynamic efficiency compared to legacy R134a systems. For technicians, understanding the mechanical and electrical nuances of the HYB60MGU is essential for ensuring system longevity.

Technical Data Sheet: Huayi HYB60MGU

Feature Specification
Model HYB60MGU
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigerators / Freezers
Oil Type and Quantity Mineral Oil / 180 ml
Horsepower (HP) 1/7 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1 Phase
Cooling Capacity BTU 375 BTU/h (approx. 110 Watts)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 6.0 cm³
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Standard LBP operation)
Capillary Recommendation 0.026″ – 0.028″ ID (Varies by cabinet)
Application Range -35°C to -10°C
Cooling System Static (Natural convection)
Commercial Classification Residential / Household
Amperage (Running) 0.55 A – 0.7 A
LRA (Locked Rotor Amperage) 4.8 A
Type of Relay PTC (Positive Temperature Coefficient)
Capacitor Requirement None (RSIR Configuration)

Electrical Wiring Schema (RSIR Configuration)

The terminal housing of the Huayi HYB60MGU follows a standard triangular pin configuration which is critical for proper startup and protection.

Schema Description:

  • Common (C): The apex pin. This pin connects to the Thermal Overload Protector (OLP), which monitors the motor temperature and current draw.
  • Start (S): The pin usually on the right side. It is momentarily energized by the PTC relay to initiate rotation.
  • Main/Run (M): The pin on the left side. This winding remains energized throughout the operation of the compressor.

Wiring Logic:
Line (Hot) -> Overload Protector -> Common Pin
Neutral -> PTC Relay -> Main Pin & Start Pin

Engineering Note: Always verify the resistance between C-S and C-M. The sum of these two measurements should roughly equal the resistance across S-M. Any significant deviation indicates a winding fault.


Comparative Efficiency: R600a vs. R134a Models

When evaluating the HYB60MGU, it is helpful to compare it against similarly rated R134a compressors to understand the benefits of the modern R600a cycle.

Metric Huayi HYB60MGU (R600a) Standard 1/7 HP (R134a)
Operating Pressure Low / Vacuum High Positive
Displacement 6.0 cm³ 4.5 cm³
Energy Consumption Low (High COP) Moderate
Environment GWP < 3 (Eco-friendly) GWP 1430 (Global Warming)

Professional Replacement Cross-Reference

In repair scenarios where the exact Huayi model is unavailable, these alternatives provide the same cooling capacity and displacement.

5 Replacements in R600a (Same Gas):

  1. Embraco: EMT45HDR (High-reliability alternative)
  2. Secop (Danfoss): TLES5.7KK.3 (Common European replacement)
  3. Jiaxipera: T1112Y (Found in many Beko/Haier units)
  4. Donper: A60CY
  5. Wanbao: ETA60

5 Replacements in R134a (Conversion Required):
Note: Converting from R600a to R134a requires a full system flush and capillary resizing.

  1. Zem: GL60AA
  2. Embraco: EMI 45HER
  3. Secop: TLS5F
  4. Huayi: B30H
  5. Cubigel: GL60AA

Field Engineering Advice and Notices

  • Vacuuming Procedure: Because R600a systems operate at very low pressures, moisture is a catastrophic contaminant. Always pull a vacuum down to at least 200 microns before charging.
  • Charging by Weight: R600a is highly sensitive to overcharging. Always use a digital scale and charge precisely to the manufacturer’s specification (usually 40-60 grams). Do not charge by pressure.
  • Flammability Safety: R600a is isobutane. Ensure no open flames are nearby during charging or discharging. Use “Lokring” cold connections if you are not in a controlled, ventilated environment for brazing.
  • Overload Protection: If the compressor “clicks” but fails to start, check the PTC relay first. These components are prone to cracking due to heat cycles.

Conclusion and Professional Benefit

The Huayi HYB60MGU is a resilient unit that, when maintained correctly, offers years of silent and efficient operation. Its low running amperage makes it an ideal choice for off-grid or solar-powered refrigeration setups where energy conservation is paramount. For the service technician, its standard footprint and predictable electrical behavior make it a preferred model in the field.

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro
Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro