ZMC GL80AF R134a Hermetic Compressor

Category: RefrigerationPublished: 2025-12-27Updated: 2025-12-27
ZMC GL80AF R134a 1/5 HP hermetic refrigerator compressor technical data and applications Mbsmgroup Mbsm.pro mbsmpro.com mbsm.
ItemValue (typical)Note
Compressor familyGL80AFZMC hermetic piston, household/commercial use.​
Nominal power≈ 1/5 HPLBP R134a rating from GL80 family table.​
RefrigerantR134aFor CFC‑free domestic refrigeration.​
ApplicationLBP (freezer/fridge)Designed for evaporating temps down to about −23 °C.​
Voltage / frequency220–230 V, 50/60 HzSingle‑phase, wide operating range.​
Motor typeRSIR / RSCRStandard ZMC design for this family.​
Country of originEgyptZMC plant in 10th of Ramadan City.​

Refrigerants, Standing, Suction and Discharge Pressures for Modern HVAC Systems

Category: RefrigerationPublished: 2025-12-27Updated: 2025-12-27
Explore a practical refrigerant pressure chart with typical standing, suction and discharge pressures plus boiling points for R22, R134a, R32, R404A, R407C, R410A, R290, R600a and R417A.
RefrigerantApprox. standing pressureApprox. suction pressureApprox. discharge pressureBoiling point (°C)Typical replacement for
R22150–155 psi / 1034–1069 kPa ​60–70 psi / 413–483 kPa ​250–300 psi / 1724–2069 kPa ​−40.8 °C ​R11 / legacy R22 AC ​
R134a80–95 psi / 552–655 kPa ​12–15 psi / 83–103 kPa ​~150 psi / 1034 kPa ​−26.2 °C ​R12 in domestic & auto ​
R600a40–50 psi / 276–345 kPa ​≈0–1 psi / 0–7 kPa ​~150 psi / 1034 kPa ​−11.7 °C ​Low‑charge fridges, R12 ​
R32240–245 psi / 1655–1689 kPa ​110–115 psi / 758–793 kPa ​175–375 psi / 1207–2586 kPa ​−52.0 °C ​High‑efficiency R410A/R22 ​
R290125–130 psi / 862–896 kPa ​65–70 psi / 448–483 kPa ​275–300 psi / 1896–2069 kPa ​−42.1 °C ​R22 in some systems ​
R407C180–185 psi / 1241–1276 kPa ​75–80 psi / 517–552 kPa ​275–300 psi / 1896–2069 kPa ​−45.0 °C (bubble) ​R22 retrofits ​
R404A180–185 psi / 1241–1276 kPa ​80–90 psi / 552–621 kPa ​275–300 psi / 1896–2069 kPa ​−46.2 °C ​R502 low‑temp systems ​
R410A225–230 psi / 1551–1586 kPa ​120–130 psi / 828–896 kPa ​450–500 psi / 3103–3447 kPa ​−51.4 °C ​Modern R22 AC ​
R417A~140 psi / 965 kPa standing ​~65 psi / 448 kPa suction ​~261 psi / 1796 kPa discharge ​−39.0 °C ​R22 service blend ​

LG T1387NEHVE 13.2 kg Smart Inverter, Washing Machine

Category: EquipmentPublished: 2025-12-26Updated: 2025-12-26
The label fixed to the side of the LG T1387NEHVE washing machine is more than a simple sticker; it is a compact technical identity card that tells you exactly what this appliance can do, how…
ItemValue
Model nameLG T1387NEHVE top load fully automatic washer.​
Washing capacity13.2 kg laundry load.​
Power supply220–240 V, 50 Hz single‑phase.​
Rated input (wash)Around 200 W according to the label in the image.
Motor typeSmart Inverter motor with LoDecibel quiet system.​
Wash technologiesSmart Motion, TurboDrum, Punch+3, Side Waterfall, Auto Pre‑Wash.​
Drum materialStainless‑steel (STS) top‑loading drum.​
Dimensions (H × W × D)Approx. 990 × 590 × 606 mm.​
Net weightAbout 42 kg.​
Protection ratingIPX4 splash‑proof cabinet (from nameplate).
Country of manufactureVietnam, production date 06/2019.
Product / code familyT1387NEHVE.ASFPEEC – belongs to LG 13–13.2 kg smart inverter series.​

Compressor database chart Relay Olp 

Category: EquipmentPublished: 2025-12-26Updated: 2025-12-26
A refrigerator compressor does not run alone; it depends on a start relay and an overload protector (OLP) to start safely and avoid burning out. The wiring diagram of compressor, relay, and OLP shows how…
FunctionConnection in circuit (typical fridge)Notes for technicians
OLP inputLine from thermostat or control boardAlways in series with compressor common. ​
OLP outputCompressor C terminalOpens on overload/overheat. ​
Relay common terminalLine or OLP output (depending on design)Feeds S and R during start. ​
Relay output to start (S)Compressor start pin via PTC or coil contactEnergized only at startup. ​
Relay output to run (R)Compressor run pin, sometimes via capacitorStays energized in running mode. ​
Capacitor connectionBetween S and R (CSR) or between line and auxiliary windingImproves torque and reduces current. ​
Approx. HPSupply (V/Hz)Typical FLA (A)Typical LRA (A)Recommended relay typeOLP trip current range (A)Typical application
1/12 HP220–240 V / 500.6–0.96–10Small PTC relay module1.2–1.6Mini bar, very small refrigerator ​
1/10 HP220–240 V / 500.8–1.18–14PTC or solid-state relay1.6–2.0Single-door compact fridge ​
1/8 HP220–240 V / 501.0–1.410–18PTC / current relay2.0–2.5Small domestic fridge–freezer ​
1/6 HP220–240 V / 501.3–1.814–24PTC or CSR relay with capacitor2.5–3.2Standard top-freezer refrigerator ​
1/5 HP220–240 V / 501.5–2.218–30CSR relay (start capacitor + PTC/current)3.0–3.8Larger domestic fridge, small showcase ​
1/4 HP220–240 V / 501.8–2.622–35CSR relay with start capacitor3.5–4.5Large refrigerator / light commercial ​
1/3 HP220–240 V / 502.3–3.530–50High-torque CSR relay module4.5–6.0Commercial display, glass-door cooler ​

Electrostar 16 foot refrigerator 1/6 HP compressor 125W top freezer Mbsmgroup

Category: RefrigerationPublished: 2025-12-25Updated: 2025-12-25
Electrostar’s 16‑foot refrigerator remains a practical choice for families who want reliable cooling and manageable energy use. With a capacity of roughly 315–330 liters and a compact top‑freezer layout, it relies on a small 1/6…
ParameterTypical Electrostar 16‑ft value
Total capacityAbout 315–330 liters.​
ConfigurationTop‑mount freezer, two doors.​
Compressor nominal powerAround 1/6 HP (≈125 W) for domestic use.​
Average running wattageRoughly 100–300 W depending on load and ambient temperature.​
Cooling systemStatic defrost or No‑Frost forced air, model‑dependent.​
Energy classDesigned for A or A+ energy labels in regional markets.​

Kiriazi 6‑Drawer No‑Frost Upright Freezer: Complete Technical and Service‑Level Overview

Category: RefrigerationPublished: 2025-12-25Updated: 2025-12-25
The Kiriazi 6‑drawer no‑frost upright freezer is designed for households and technicians who expect serious performance from a domestic appliance. With a tall, space‑saving cabinet, six organized drawers and a tropicalized 1/6 hp compressor, it…
ItemSpecification
Brand / modelKiriazi KH256VF / UGH0044N upright deep freezer​
TypeFreestanding vertical no‑frost freezer, 6 drawers​
Gross / net capacityAround 270 liters total storage​
Drawers6 storage drawers + extra ice/fast‑freeze compartment​
Dimensions (W × D × H)62 × 67 × 163.6–164 cm​
Cooling systemForced‑air evaporator, automatic no‑frost fan system​
FeaturesFast‑freeze mode, digital display, open‑door alarm, info labels per drawer​
InsulationHigh‑efficiency polyurethane, thickness about 8–10 cm​
Cabinet materialAnti‑rust steel outer body with plastic inner liner​
ParameterValue
Power supply220 V, 50 Hz ±10%​
Compressor capacity (ASHRAE 23.3 °C)156 W tropical hermetic compressor​
Approx. compressor hp class≈ 1/6 hp low‑back‑pressure, typical for 250–270 L upright freezers​
Cooling rating3–4 star freezing performance​
Monthly energy consumptionAbout 34 kWh/month, high‑efficiency class for its segment​
Energy‑saving featuresThick insulation, fan stop when door opens, optimized air circulation​
ComponentTypical data for KH256VF‑class unit
RefrigerantR134a, used widely in Kiriazi domestic uprights of this size and period​
Estimated refrigerant chargeApprox. 120–150 g R134a (230 L Kiriazi uprights use ≈120 g; 270 L models usually fall slightly higher)​
Expansion deviceCapillary tube feeding a forced‑air evaporator (no‑frost)​
Practical capillary range (service reference)Internal diameter about 0.7–0.8 mm with 2.5–3.0 m length for 1/6 hp R134a low‑temperature application; exact factory size is not published and should be copied from the original tube when available.​​
Compressor typeTropical hermetic LBP compressor, designed for high ambient temperatures​
Recommended oil typePOE (polyolester) oil for R134a domestic compressors, viscosity ISO 22–32​
Typical oil quantityAround 200–300 ml for 1/6 hp hermetic can, exact value depends on compressor model plate​​

Zanussi 16 Cubic Feet Refrigerator Compressor GL90AA – 1/4 HP R134a

Category: RefrigerationPublished: 2025-12-25Updated: 2025-12-25
A 16 cubic feet Zanussi refrigerator typically relies on the GL90AA hermetic compressor, a compact piston unit built for R134a and low back pressure applications. This 1/4 HP motor offers cooling capacities from roughly 165…
ParameterTypical GL90AA valuePractical meaning
ApplicationLow Back Pressure, R134a.​Designed for household fridges and freezers.
Nominal power1/4 HP.​Common rating for 14–16 ft³ refrigerators.
Cooling capacity≈165–224 W at low evaporating temps; up to ≈330–346 W near −10 °C; some catalogs give 407 W at −10 °C in optimized conditions.​Covers the needs of a 16 ft³ Zanussi fridge‑freezer.
Displacement9.08–9.09 cm³.​Defines the volume of gas compressed each stroke.
Voltage / frequency220–240 V, 50 Hz; voltage range about 187–264 V.​Compatible with residential grids in Tunisia, Egypt and Europe.
Motor typeRSIR (some GLY90 variants CSIR).​Uses start relay and overload protector.
Max ambient43 °C.​Important for hot‑climate kitchens and workshops.
Oil type / chargeEster oil, about 295–345 cm³.​Requires clean, dry circuit without mineral oil.
Appliance featureRequirement for Zanussi 16 ft³How GL90AA fits
Net volumeAround 370–425 L (≈14–16 ft³).​Cooling capacity up to ≈346–407 W covers this volume in R134a systems.​
RefrigerantR134a sealed system.GL90AA is optimized and rated only for R134a.
Ambient classUp to about 43 °C.Compressor carries a 43 °C max ambient rating.
Energy and noiseDomestic, continuous duty.RSIR design and static cooling balance efficiency and cost.

Samsung front‑load tub front half assembly: dimensions, components and replacement guide

Category: EquipmentPublished: 2025-12-25Updated: 2025-12-25
The tub front half assembly on Samsung front‑load washing machines combines the plastic support ring, EPDM rubber door gasket, drain hose and spring‑loaded clamp into one critical sealing unit between the drum and cabinet. It…
ParameterTypical range (mm)Technical role
Inner opening diameter≈300–330Defines usable drum access and must match door glass and hinge geometry.​
Outer tub front diameter≈380–420Matches cabinet cut‑out and rear tub half for correct bolt alignment.​
Seal width / lip depth≈40–60Controls how deeply the gasket overlaps the drum rim and door glass to avoid leaks.​​
Drain‑hose connector length≈60–80Provides sufficient fall for water to clear the boot and flow to the pump housing.​

Finder 66.82.8.230.0000 Power Relay: Reliable 30A Solution for HVAC and Industrial Control

Category: EquipmentPublished: 2025-12-25Updated: 2025-12-25
The Finder 66.82.8.230.0000 is a high‑power, flange‑mount relay designed for demanding switching tasks in HVAC, refrigeration and industrial control panels. With a 230 V AC coil and 30 A contact rating, it offers a compact…
SpecificationValueNotes
Manufacturer / SeriesFinder 66.82Power relays 30 A series.​
Coil voltage230 V ACStandard mains control voltage.​
Contact configurationDPDT (2CO)Two changeover contacts.​
Max. switching current30 APer contact set for AC loads.​
Max. switching voltage440 V ACFor power applications.​
TerminalsFaston 6.3 × 0.8 mmFor push‑on connectors.​
MountingFlange mountFor panel or chassis mounting.​
InsulationReinforced between coil and contactsAccording to EN 60335‑1.​

Tecumseh CAJ9480T R22 Hermetic Compressor: Complete Technical Guide for Professionals

Category: RefrigerationPublished: 2025-12-25Updated: 2025-12-25
The Tecumseh / L’Unité Hermetique CAJ9480T is a 5/8 HP hermetic compressor delivering about 1 968 W of cooling capacity for R22 commercial refrigeration systems. It is widely used in small cold rooms, display cabinets…
SpecificationCAJ9480T value (R22, 50 Hz)
RefrigerantR22 (and some approved retrofits such as R438A on specific codes)​
Application rangeMedium / high back pressure (commercial refrigeration)​
Nominal horsepower (HP)5/8 HP (0.625 HP)​
Nominal cooling capacity (W)≈ 1 968 W at EN12900: 220 V, 50 Hz, +5 °C evap / +50 °C cond​
Input electrical power (W)≈ 780–800 W at the same EN12900 rating point​
Displacement15.2 cm³/rev​
Supply voltage220–240 V, 1‑phase, 50 Hz​
Voltage range187–242 V (50 Hz)​
Rated load amps (RLA, 50 Hz)≈ 4 A​
Locked rotor amps (LRA)≈ 24 A​
Oil type / quantitySynthetic alkylate or mineral, approx. 475–887 cm³ depending on version​
Net weight≈ 19–22 kg​