A problem with a Brand refrigerator: ice forms, it makes a noise, and it stops cooling mbsmpro
12, Apr 2026
A problem with a Brand refrigerator: ice forms, it makes a noise, and it stops cooling
image_pdfimage_print

The issues you are experiencing with your Brandt refrigerator (ice buildup, unusual noise, and poor cooling) indicate a failure in the No Frost defrost system. Since a specialist was unable to fix it, the fault may have been misdiagnosed.

Here is the translation of the causes and solutions provided:


Possible Causes and Solutions

1. Clogged Drain Line (Canal d’évacuation bouché)

  • The Cause: When ice melts during the defrost cycle, water must flow into the rear tray through a drain tube. If blocked, water freezes in the evaporator, obstructing airflow and cooling.
  • The Solution:
    1. Unplug the refrigerator.
    2. Locate the drain hole at the bottom of the freezer compartment.
    3. Pour hot water into the hole to melt any ice blockage.
    4. Use a thin wire or compressed air to ensure the tube is completely clear.

2. Faulty Ventilation Fan (Ventilateur bloqué ou HS)

  • The Cause: The fan distributes cold air. If it gets stuck due to ice buildup or suffers a mechanical failure, it will make noise and the fridge will stop cooling.
  • The Solution:
    1. After defrosting the unit, turn it on and check if the fan spins when the door is closed.
    2. If it doesn’t spin, try moving it manually. If it remains stuck, it likely needs replacement.

3. Defective Defrost Heater (Résistance de dégivrage)

  • The Cause: This heater melts ice periodically. If it fails, ice will accumulate continuously.
  • The Solution:
    1. Test the heater using a multimeter (Ohms setting).
    2. If the circuit is broken, the part must be replaced by a specialist.

4. Damaged Temperature Sensor or Thermostat (Sonde HS)

  • The Cause: If the sensor is faulty, the system won’t know when to trigger the defrost cycle, leading to excessive ice.
  • The Solution:
    1. Replace the sensor (this is usually an inexpensive and straightforward fix).

What Should You Do Now?

  1. Manual Defrost: Manually defrost the unit and follow the steps above.
  2. Monitor: If the problem returns after a few days, the issue is likely electrical (the heater, sensor, or timer/control board).
  3. Professional Check: For a permanent fix, ask a technician to specifically measure the resistance (heater) and the sensor rather than just performing a manual defrost.

[!CAUTION] Important Advice: Never scrape ice with sharp tools (like knives) to avoid puncturing the cooling coils, which would cause a permanent refrigerant leak.

A problem with a Brand refrigerator: ice forms, it makes a noise, and it stops cooling mbsmpro

Leave a Reply

Your email address will not be published. Required fields are marked *

Related Posts

Jiaxipera VTH1113Y Compressor: R600a

Jiaxipera VTH1113Y is a high-efficiency inverter compressor using R600a refrigerant. Designed for LBP applications, it operates on 220-240V and offers…

Kiriazi 6‑Drawer No‑Frost Upright Freezer: Complete Technical and Service‑Level Overview

The Kiriazi 6‑drawer no‑frost upright freezer is designed for households and technicians who expect serious performance from a domestic appliance.…

Panasonic SFH39C73H Compressor Specs and Replacements

The Panasonic SFH39C73H is a compact 1/5 HP compressor designed for R134a refrigeration systems, commonly found in domestic refrigerators and…

Panasonic QB66C13GAX5 Compressor Specs and Replacements

The Panasonic QB66C13GAX5 is a reliable 1/5 HP compressor designed for R134a LBP systems, commonly found in domestic refrigerators and…

Huayi HYE55YL63 and ZMC EGM60AF

The Huayi HYE55YL63 and ZMC EGM60AF are two industry-standard 1/5 HP compressors used in domestic refrigerators. While both utilize R134a…

 Copeland-15hp

The photos show a Copeland condensing unit on a steel base, with a semi‑hermetic compressor, air‑cooled condenser and vertical liquid…