Technical data, tools and notes for refrigeration and electronics technicians.

donper-r134a-compressor-specs-l58-l65-l72-k270-k375
22, Jan 2026
compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP
image_pdfimage_print

Compresseur Réfrigérateur DONPER

Référence: K270CZ1R134A 1/3HP

DONPER Refrigerator Compressor

Référence: L58CZ1R134A 1/6HP

DONPERCompresseur Réfrigérateur

Référence: L65CZ1R134A 1/5HP

DONPER Refrigerator Compressor

Référence: L72CZ1R134A 1/4HP

DONPER Refrigerator Compressor

K270CZ1 R134A 1/3HP

DONPER Refrigerator Compressor

K375CZ1R134A 1/2HP

Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

In the HVAC and refrigeration industry, the Donper brand has become a synonymous name for reliability and cost-effective performance. Specializing in hermetic reciprocating technology, Donper’s R134a lineup—specifically the L-series and K-series—covers the vast majority of domestic and light commercial needs. From a small 1/6 HP refrigerator to a robust 1/2 HP commercial chest freezer, these compressors are engineered to handle varying thermal loads with consistent efficiency.

As a field technician or engineer, selecting the correct replacement or designing a system requires more than just knowing the horsepower. It requires a deep dive into displacement, motor torque, and winding characteristics. Below, we provide the definitive technical breakdown of the most common Donper R134a models.


Comparative Analysis: The Donper R134a Series

The transition from the L-series to the K-series marks a shift from residential “static” cooling to more demanding commercial “forced-air” or high-capacity “static” cooling. While the L58CZ1 is the quiet heart of a kitchen fridge, the K375CZ1 is the workhorse of the supermarket display.

ModelHPDisplacement (cc)Cooling Cap (W)Efficiency (W/W)Motor Type
L58CZ11/65.81401.15RSIR
L65CZ11/56.51651.20RSIR
L72CZ11/47.21951.25RSIR/RSCR
K270CZ11/39.52701.30RSCR
K375CZ11/212.53751.35CSIR


Detailed Technical Data Sheets

Below are the exhaustive specifications for each model mentioned. This data is critical for calculating capillary tube lengths and ensuring electrical compatibility.

1. Donper L-Series (Domestic Focus)

FeatureL58CZ1 (1/6 HP)L65CZ1 (1/5 HP)L72CZ1 (1/4 HP)
UtilisationLBPLBPLBP
DomaineCooling / FreezingCooling / FreezingCooling / Freezing
Oil Type / QtyPOE – 180mlPOE – 200mlPOE – 210ml
Power Supply220-240V 50Hz220-240V 50Hz220-240V 50Hz
Cooling Capacity478 BTU/h563 BTU/h665 BTU/h
Motor TypeRSIRRSIRRSIR/RSCR
Winding MaterialCopperCopperCopper
Pressure Charge100-120 PSI (Static)100-120 PSI (Static)110-130 PSI (Static)
Capillary (Typical)0.028″ x 3m0.031″ x 3m0.036″ x 3m
Fan RequiredNo (Static)No (Static)Optional
LRA (Amps)6.5 A8.0 A9.5 A
CapacitorN/AN/A4-5 µF (if RSCR)

2. Donper K-Series (Commercial Focus)

FeatureK270CZ1 (1/3 HP)K375CZ1 (1/2 HP)
UtilisationLBP / MBPLBP / MBP
DomaineLarge FreezingCommercial Freezing
Oil Type / QtyPOE – 250mlPOE – 300ml
Power Supply220-240V 50Hz220-240V 50Hz
Cooling Capacity921 BTU/h1280 BTU/h
Motor TypeRSCRCSIR (Start Cap)
Winding MaterialCopperHigh-Temp Copper
Pressure Charge120-140 PSI (Static)140-160 PSI (Static)
Capillary (Typical)0.042″ x 2.5m0.050″ x 2.5m
Fan RequiredRecommendedYes (Forced Air)
LRA (Amps)12.0 A18.0 A
Capacitor6 µF (Run)60-80 µF (Start)


Cross-Reference & Replacement Guide

When the exact Donper model is unavailable, the following industry-standard alternatives can be utilized. Ensure you verify the mounting foot dimensions as they may vary slightly between brands.

5 Standard Replacements (R134a)

  1. Embraco: FFI10HAK (for 1/3 HP) / FFI12HBX (for 1/2 HP)
  2. Secop/Danfoss: TLES8.7KK.3 / NL11F
  3. Tecumseh: THB1390Y / AEA3440Y
  4. Huayi: HYE90MT / HYE121MT
  5. Jiaxipera: ND1114Y / NT1116Y

5 Alternative Gas Replacements (System Flush Required)

  1. Donper (R600a): D65CY1 (for 1/5 HP applications)
  2. Secop (R290): NLE11KK (High Efficiency)
  3. Embraco (R600a): EMX3115Y
  4. Cubigel (R290): GLY12RA
  5. LG (R600a): BSA075LHE

Engineering Best Practices & Maintenance

Expert Advice: The K375CZ1 (1/2 HP) generates significant heat during the compression cycle. If installing this in a confined space, a condenser fan is non-negotiable. Lack of airflow will lead to oil carbonization and premature valve failure.

  • Vacuuming: Always pull a vacuum down to 500 microns. R134a uses POE oil, which is highly hygroscopic (absorbs moisture). Moisture in the system leads to acid formation that eats through copper windings.
  • Capillary Match: When moving from a 1/6 HP to a 1/4 HP compressor, you must resize the capillary tube. Using an undersized capillary will cause high head pressure and trip the thermal overload protector.
  • Relay Testing: If the compressor fails to start but hums, check the PTC relay or the Start Capacitor (on 1/2 HP models). Donper relays are standardized, but always match the Ohm resistance of the original part.

Focus Keyphrase: Donper R134a Refrigerator Compressor Technical Specs L58CZ1 L65CZ1 L72CZ1 K270CZ1 K375CZ1

SEO Title: Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

Meta Description: Full technical data sheets for Donper R134a compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP). Includes cross-reference and wiring tips.

Slug: donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, K270CZ1, L58CZ1, L65CZ1, L72CZ1, K375CZ1, R134a, Refrigerator Compressor, Replacement, LBP, RSIR, CSIR, Embraco Replacement, HVAC, Technical Guide.

Excerpt: Donper has established itself as a powerhouse in the hermetic compressor industry, providing reliable cooling solutions for domestic and light commercial applications. This technical analysis explores the R134a L and K series, ranging from 1/6 HP to 1/2 HP, offering engineers and technicians the critical data needed for successful repairs and system optimizations.


Donper Series – R134a Refrigerant (LBP, 220V/50Hz)

These models feature aluminum windings (Al-wire) and are designed for Low Back Pressure (LBP) applications.

ModelPower (HP)Cooling Capacity (W)Power SupplyWire Type
S53CW11/8 HP135W220V/50HzAluminum
L58CZ11/6 HP145W220V/50HzAluminum
L65CZ11/5 HP170W220V/50HzAluminum
L72CZ11/4 HP195W220V/50HzAluminum
L76CZ11/4 HP+215W220V/50HzAluminum
K230CZ11/4 HP+230W220V/50HzAluminum
K270CZ11/3 HP270W220V/50HzAluminum
K325CZ11/3 HP325W220V/50HzAluminum

Donper Series – R600a Refrigerant (LBP, 220V/50Hz)

Models optimized for Isobutane (R600a), also using aluminum motor windings.

ModelPower (HP)Cooling Capacity (W)Power SupplyWire Type
A120CY1T1/8 HP118W220V/50HzAluminum
A145CY1A1/6 HP138W220V/50HzAluminum
S100CY11/5 HP168W220V/50HzAluminum
S118CY11/4 HP200W220V/50HzAluminum
L140CY11/4 HP+235W220V/50HzAluminum

Technical Definitions

  • LBP (Low Back Pressure): Optimized for low evaporating temperatures (typically -35°C to -10°C), making them ideal for household freezers and refrigerators.
  • Cooling Capacity (W): Measured in Watts, representing the amount of heat the compressor can remove per hour under standard test conditions (ASHRAE).
  • Al-wire (Aluminum Wire): A cost-effective alternative to copper. While lighter, it requires specific handling during repair and is generally found in “entry-level” or standard domestic units.

Leave a Reply

Your email address will not be published. Required fields are marked *

Related Posts

Replacing Unionaire Sensors with Kiriazi Deep Freezer Probes: What Technicians Must Check First

The picture shows a refrigeration technician holding several tubular temperature probes and a small white connector in front of a…

WPMR91S, the refrigerator requires exactly 13 grams of R600a refrigerant.

The White Point WPMR91S is a high-efficiency 91-liter refrigerator utilizing a specialized 13-gram R600a refrigerant charge. Operating at 0.50A, this…

Copeland KCE444HAG hermetic compressor

Copeland KCE444HAG Compressor, 3/8 Hp, R134a, 230V 50Hz – Technical Specs and Water Cooler Applications

Copeland ZR61KCE‑TF7‑522

The data plate on the Copeland ZR61KCE‑TF7‑522 compressor matches the official Copeland Scroll specifications for R407C air‑conditioning duty and includes…

BASIC TN1900 Refrigerator Compressor

The BASIC TN1900 represents a medium-displacement hermetic reciprocating compressor engineered for low back pressure refrigeration applications. This Syrian-manufactured unit operates…

Jiaxipera VTH1113Y Compressor: R600a

Jiaxipera VTH1113Y is a high-efficiency inverter compressor using R600a refrigerant. Designed for LBP applications, it operates on 220-240V and offers…