compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP

donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Compresseur Réfrigérateur DONPER

Référence: K270CZ1R134A 1/3HP

DONPER Refrigerator Compressor

Référence: L58CZ1R134A 1/6HP

DONPERCompresseur Réfrigérateur

Référence: L65CZ1R134A 1/5HP

DONPER Refrigerator Compressor

Référence: L72CZ1R134A 1/4HP

DONPER Refrigerator Compressor

K270CZ1 R134A 1/3HP

DONPER Refrigerator Compressor

K375CZ1R134A 1/2HP

Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

In the HVAC and refrigeration industry, the Donper brand has become a synonymous name for reliability and cost-effective performance. Specializing in hermetic reciprocating technology, Donper’s R134a lineup—specifically the L-series and K-series—covers the vast majority of domestic and light commercial needs. From a small 1/6 HP refrigerator to a robust 1/2 HP commercial chest freezer, these compressors are engineered to handle varying thermal loads with consistent efficiency.

As a field technician or engineer, selecting the correct replacement or designing a system requires more than just knowing the horsepower. It requires a deep dive into displacement, motor torque, and winding characteristics. Below, we provide the definitive technical breakdown of the most common Donper R134a models.


Comparative Analysis: The Donper R134a Series

The transition from the L-series to the K-series marks a shift from residential “static” cooling to more demanding commercial “forced-air” or high-capacity “static” cooling. While the L58CZ1 is the quiet heart of a kitchen fridge, the K375CZ1 is the workhorse of the supermarket display.

Model HP Displacement (cc) Cooling Cap (W) Efficiency (W/W) Motor Type
L58CZ1 1/6 5.8 140 1.15 RSIR
L65CZ1 1/5 6.5 165 1.20 RSIR
L72CZ1 1/4 7.2 195 1.25 RSIR/RSCR
K270CZ1 1/3 9.5 270 1.30 RSCR
K375CZ1 1/2 12.5 375 1.35 CSIR

Detailed Technical Data Sheets

Below are the exhaustive specifications for each model mentioned. This data is critical for calculating capillary tube lengths and ensuring electrical compatibility.

1. Donper L-Series (Domestic Focus)

Feature L58CZ1 (1/6 HP) L65CZ1 (1/5 HP) L72CZ1 (1/4 HP)
Utilisation LBP LBP LBP
Domaine Cooling / Freezing Cooling / Freezing Cooling / Freezing
Oil Type / Qty POE – 180ml POE – 200ml POE – 210ml
Power Supply 220-240V 50Hz 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 478 BTU/h 563 BTU/h 665 BTU/h
Motor Type RSIR RSIR RSIR/RSCR
Winding Material Copper Copper Copper
Pressure Charge 100-120 PSI (Static) 100-120 PSI (Static) 110-130 PSI (Static)
Capillary (Typical) 0.028″ x 3m 0.031″ x 3m 0.036″ x 3m
Fan Required No (Static) No (Static) Optional
LRA (Amps) 6.5 A 8.0 A 9.5 A
Capacitor N/A N/A 4-5 µF (if RSCR)

2. Donper K-Series (Commercial Focus)

Feature K270CZ1 (1/3 HP) K375CZ1 (1/2 HP)
Utilisation LBP / MBP LBP / MBP
Domaine Large Freezing Commercial Freezing
Oil Type / Qty POE – 250ml POE – 300ml
Power Supply 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 921 BTU/h 1280 BTU/h
Motor Type RSCR CSIR (Start Cap)
Winding Material Copper High-Temp Copper
Pressure Charge 120-140 PSI (Static) 140-160 PSI (Static)
Capillary (Typical) 0.042″ x 2.5m 0.050″ x 2.5m
Fan Required Recommended Yes (Forced Air)
LRA (Amps) 12.0 A 18.0 A
Capacitor 6 µF (Run) 60-80 µF (Start)

Cross-Reference & Replacement Guide

When the exact Donper model is unavailable, the following industry-standard alternatives can be utilized. Ensure you verify the mounting foot dimensions as they may vary slightly between brands.

5 Standard Replacements (R134a)

  1. Embraco: FFI10HAK (for 1/3 HP) / FFI12HBX (for 1/2 HP)
  2. Secop/Danfoss: TLES8.7KK.3 / NL11F
  3. Tecumseh: THB1390Y / AEA3440Y
  4. Huayi: HYE90MT / HYE121MT
  5. Jiaxipera: ND1114Y / NT1116Y

5 Alternative Gas Replacements (System Flush Required)

  1. Donper (R600a): D65CY1 (for 1/5 HP applications)
  2. Secop (R290): NLE11KK (High Efficiency)
  3. Embraco (R600a): EMX3115Y
  4. Cubigel (R290): GLY12RA
  5. LG (R600a): BSA075LHE

Engineering Best Practices & Maintenance

Expert Advice: The K375CZ1 (1/2 HP) generates significant heat during the compression cycle. If installing this in a confined space, a condenser fan is non-negotiable. Lack of airflow will lead to oil carbonization and premature valve failure.

  • Vacuuming: Always pull a vacuum down to 500 microns. R134a uses POE oil, which is highly hygroscopic (absorbs moisture). Moisture in the system leads to acid formation that eats through copper windings.
  • Capillary Match: When moving from a 1/6 HP to a 1/4 HP compressor, you must resize the capillary tube. Using an undersized capillary will cause high head pressure and trip the thermal overload protector.
  • Relay Testing: If the compressor fails to start but hums, check the PTC relay or the Start Capacitor (on 1/2 HP models). Donper relays are standardized, but always match the Ohm resistance of the original part.

Focus Keyphrase: Donper R134a Refrigerator Compressor Technical Specs L58CZ1 L65CZ1 L72CZ1 K270CZ1 K375CZ1

SEO Title: Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

Meta Description: Full technical data sheets for Donper R134a compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP). Includes cross-reference and wiring tips.

Slug: donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, K270CZ1, L58CZ1, L65CZ1, L72CZ1, K375CZ1, R134a, Refrigerator Compressor, Replacement, LBP, RSIR, CSIR, Embraco Replacement, HVAC, Technical Guide.

Excerpt: Donper has established itself as a powerhouse in the hermetic compressor industry, providing reliable cooling solutions for domestic and light commercial applications. This technical analysis explores the R134a L and K series, ranging from 1/6 HP to 1/2 HP, offering engineers and technicians the critical data needed for successful repairs and system optimizations.


Donper Series – R134a Refrigerant (LBP, 220V/50Hz)

These models feature aluminum windings (Al-wire) and are designed for Low Back Pressure (LBP) applications.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
S53CW1 1/8 HP 135W 220V/50Hz Aluminum
L58CZ1 1/6 HP 145W 220V/50Hz Aluminum
L65CZ1 1/5 HP 170W 220V/50Hz Aluminum
L72CZ1 1/4 HP 195W 220V/50Hz Aluminum
L76CZ1 1/4 HP+ 215W 220V/50Hz Aluminum
K230CZ1 1/4 HP+ 230W 220V/50Hz Aluminum
K270CZ1 1/3 HP 270W 220V/50Hz Aluminum
K325CZ1 1/3 HP 325W 220V/50Hz Aluminum

Donper Series – R600a Refrigerant (LBP, 220V/50Hz)

Models optimized for Isobutane (R600a), also using aluminum motor windings.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
A120CY1T 1/8 HP 118W 220V/50Hz Aluminum
A145CY1A 1/6 HP 138W 220V/50Hz Aluminum
S100CY1 1/5 HP 168W 220V/50Hz Aluminum
S118CY1 1/4 HP 200W 220V/50Hz Aluminum
L140CY1 1/4 HP+ 235W 220V/50Hz Aluminum

Technical Definitions

  • LBP (Low Back Pressure): Optimized for low evaporating temperatures (typically -35°C to -10°C), making them ideal for household freezers and refrigerators.
  • Cooling Capacity (W): Measured in Watts, representing the amount of heat the compressor can remove per hour under standard test conditions (ASHRAE).
  • Al-wire (Aluminum Wire): A cost-effective alternative to copper. While lighter, it requires specific handling during repair and is generally found in “entry-level” or standard domestic units.



Compressor, HUAYI, HYS55, HYS60, HYE81, HYE90, 1/6 hp, 1/5 hp, 1/4 hp, LBP, R134a, R600a

mbsmgroup-files-2026-01-22_031414-mbsmpro mbsmpro

Focus Keyphrase

HUAYI Refrigerator Compressor Technical Specifications HYS45 HYS55 HYS60 HYS69 HYE81 HYE90 HY113 HY131 HY153 LBP R134a R600a

SEO Title

Mbsmpro, Compressor, HUAYI, HYS55, HYS60, HYE81, HYE90, 1/6 hp, 1/5 hp, 1/4 hp, LBP, R134a, R600a

Meta Description

Professional technical guide for HUAYI compressors. Detailed data for HYS and HYE series, including HP, cooling capacity, and equivalents. Expert analysis for HVAC technicians.

Slug

huayi-compressor-hys-hye-series-technical-data-replacement

Tags

Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, HUAYI, HYS45, HYS55, HYS60, HYS69, HYE81, HYE90, HY113, HY131, HY153, ACC GVY57AA, Secop TLY8.7KK, Embraco EMT6170Z, Danfoss TLS6F, Samsung SD162, LG MA57LAJG, Panasonic QB66C13GAX5, Cubigel GL60AA, Donper LU111CY

Excerpt

The HUAYI compressor lineup, featuring the HYS and HYE series, is a cornerstone in modern domestic refrigeration. These Low Back Pressure units utilize R134a and R600a refrigerants to provide efficient cooling for household freezers and refrigerators. Designed for durability and high performance, they offer professional-grade solutions for various cooling capacities from 1/10 to 1/3 horsepower.


Technical Data Sheet: HUAYI Compressor Series

Feature Detailed Specification
Model HUAYI HYS/HYE Series (e.g., HYS60, HYE90)
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Cooling
Oil Type and Quantity POE/Mineral (160ml – 220ml depending on model)
Horsepower (HP) 1/10 HP to 1/3 HP
Refrigerant Type R134a (HYS) / R600a (HYE)
Power Supply 1Ph / 220-240V / 50Hz
Cooling Capacity BTU 380 – 800 BTU/h (Range across models)
Motor Type RSIR / RSCR
Displacement 4.5 cm³ to 15.3 cm³
Winding Material High-Quality Copper
Pression Charge 0.5 – 1.2 Bar (Suction Side)
Capillary 0.026″ to 0.031″ (Application dependent)
Refrigerator Models Samsung, LG, Whirlpool, Beko, and Generic brands
Temperature Function -35°C to -10°C
With Fan or No Static Cooling (No fan required for most)
Commercial or No Domestic / Light Commercial
Amperage in Function 0.6A – 1.3A
LRA (Locked Rotor Amps) 5.0A – 9.0A
Type of Relay PTC Start Relay
Capacitor and Value Optional (3µF – 5µF for RSCR models)

5 Compressor Replacements (Same Gas – R134a/R600a):

  1. ACC / Secop GVY57AA (R134a)
  2. Embraco EMT6170Z (R134a)
  3. Danfoss TLS6F (R134a)
  4. Panasonic QB66C13GAX5 (R600a)
  5. Jiaxipera N1113Y (R600a)

5 Compressor Replacements (Alternative Gas Equivalents):

  1. Secop TLY8.7KK.3 (Transition to R600a)
  2. Embraco EMX46CLC (Transition to R600a)
  3. Donper LU111CY (High efficiency R600a)
  4. Cubigel GL60AA (Standard R134a)
  5. Samsung SD162 (Reliable R134a alternative)

Technical Analysis: The Engineering Behind HUAYI Refrigeration

In the field of appliance repair and HVAC engineering, HUAYI has become a household name—not just for their availability, but for their consistent performance in tropical climates. Whether you are dealing with the HYS series (R134a) or the newer, eco-friendly HYE series (R600a), understanding the internal mechanics is key to a long-lasting repair.

Comparison: R134a vs. R600a Performance

While the HYS60 (1/5 HP) is a classic workhorse, the industry shift toward HYE90 (1/4 HP R600a) reflects a move toward thermodynamic efficiency. R600a (Isobutane) operates at lower pressures, which reduces the load on the compressor valves and extends the lifespan of the motor. However, from an engineering standpoint, R600a requires a larger displacement (9.0 cm³ vs 6.0 cm³) to achieve similar cooling capacity to its R134a counterparts.

Winding and Electrical Configuration

As an expert who has handled these units on the bench, I can confirm that the HUAYI motor design usually follows a RSIR (Resistive Start-Inductive Run) or RSCR (Resistive Start-Capacitive Run) configuration.

Wiring Schema for HUAYI PTC Relay:

  1. Common (C): Top Pin (Connected to Overload Protector).
  2. Main/Run (R): Right Bottom Pin.
  3. Start (S): Left Bottom Pin. For RSCR models, the capacitor is bridged between the Start and Run pins to improve torque and energy consumption.

Engineering Values: Comparison Table

Model HP Displacement (cm³) Capacity (W) Efficiency (W/W)
HYS45 1/8 4.5 110 1.15
HYS55 1/6 5.5 135 1.20
HYE81 1/5+ 8.1 145 1.45
HYE131 1/3 13.1 225 1.38

Pro Tips for Field Installation

  • Notice: When replacing an R134a compressor with an R600a unit, you must change the filter drier and perform a nitrogen purge. R600a is highly sensitive to residual moisture.
  • Benefit: Using the HYE series (RSCR) with a dedicated run capacitor can reduce electricity consumption by up to 15% compared to standard RSIR units.
  • Safety: Always verify the LRA (Locked Rotor Amps). If the compressor fails to start under load, check the PTC relay resistance. A standard HUAYI PTC should read between 15 and 30 Ohms at room temperature.

Final Verdict

The HUAYI series offers a versatile range for the artisan. While the HYS models are robust and “forgiving” regarding slightly imperfect vacuums, the HYE series is the future of high-efficiency domestic freezing. When in doubt, always size your compressor based on the Displacement (cm³) and Cooling Capacity (Watts) at -23.3°C to ensure the evaporator remains fully flooded without liquid slugging returning to the compressor.


Modèle Réf App. Puissance Capacité de refroidissement Puissance d’entrée COP Type de fil
Hp W/hr (W/W)
Référence: CMA042LHEG Référence: R134a LBP 220V/50Hz 1/8HP 107W 79W 1.31  Fil d’Al-
Référence: CMA053LHEG Référence: R134a LBP 220V/50Hz 1/6HP 150W 102W 1.48  Fil d’Al-
Référence: CMA057LHEG Référence: R134a LBP 220V/50Hz 1/5HP 163W 115W 1.42  Fil d’Al-
Référence: CMA069LHEM Référence: R134a LBP 220V/50Hz 1/4HP 195W 128W 1.52  Fil d’Al-
Référence: CMA075LAEM Référence: R134a LBP 220V/50Hz 1/4HP + 215W 130W 1.68  Fil de cuivre
LX95LHBM Référence: R134a LBP 220V/50Hz 1/3HP 267W 173W 1.25  Fil d’Al-
LX110LAJM Référence: R134a LBP 220V/50Hz 1/2HP 323W 232W 1.39  Fil de cuivre
Référence: CSB057NJEG Référence: R600a LBP 220V/50Hz 1/10HP 100W 77W 1.30  Fil d’Al-
Référence: CSB069NJEG Référence: R600a LBP 220V/50Hz 1/8HP 126W 90W 1.40  Fil d’Al-
Référence: CSB075NJEG Référence: R600a LBP 220V/50Hz 1/6HP 139W 102W 1.36  Fil d’Al-
Pièces connexes CMA082NHEM Référence: R600a LBP 220V/50Hz 1/5HP 148W 81W 1.84  Fil d’Al-
Référence: CMA098NHEM Référence: R600a LBP 220V/50Hz 1/4HP 181W 98W 1.85  Fil d’Al-
Référence: CMA110NJEM Référence: R600a LBP 220V/50Hz 1/4HP 194W 122W 1.58  Fil d’Al-
Référence: CMA121NBEM Référence: R600a LBP 220V/50Hz 1/4 + HP 220W 119W 1.85  Fil de cuivre
mbsmgroup-files-2026-01-22_031436-mbsmpro mbsmpro



ZMC GL45AN Compressor – R134a, 1/8 HP, LBP

ZMC GL45AN Compressor – R134a, 1/8 HP, LBP mbsmpro

Mbsmpro.com | ZMC GL45AN Compressor – R134a, 1/8 HP, LBP Cooling & Freezing Applications

Professional Overview

The ZMC GL45AN is a hermetic refrigeration compressor designed for domestic and light commercial refrigeration systems operating with R134a refrigerant. This model belongs to the LBP (Low Back Pressure) category and is widely used in refrigerators, beverage coolers, small freezers, and under-counter cooling equipment.

Engineered for reliability, low noise, and stable thermal performance, the GL45AN is well adapted for continuous duty cycles in temperature ranges typically found in cooling and light freezing systems. Its compact displacement and efficient motor design make it a common replacement compressor in service and maintenance operations.


Technical Identity & Operating Principle

The GL45AN operates using a single-phase RSIR motor system, optimized for energy efficiency and smooth start-up. It is oil-lubricated with mineral oil compatible with R134a, ensuring proper lubrication and long service life.

This compressor is designed to work without an external cooling fan, relying instead on natural air convection around the shell, which simplifies installation and reduces failure points.


Complete Technical Specification Table

Parameter Value
Model ZMC GL45AN
Utilisation (MBP/HBP/LBP) LBP
Domaine (Freezing / Cooling) Cooling & Light Freezing
Oil Type & Quantity Mineral Oil – approx. 180 ml
Horsepower (HP) 1/8 HP
Refrigerant Type R134a
Power Supply 220–240V / 50Hz / 1 Phase
Cooling Capacity (BTU/h) ~450–520 BTU/h
Motor Type Single-Phase Induction (RSIR)
Displacement ~4.5 cm³
Winding Material Copper
Pressure Charge Factory nitrogen holding charge
Capillary Tube 0.031″ – 0.036″ (system dependent)
Compatible Refrigerator Models Single-door fridge, minibar, beverage cooler
Temperature Function −30°C to −10°C evaporating
With Fan or No No fan
Commercial Use Yes (light commercial)
Amperage (Running) 1.1 – 1.4 A
LRA (Locked Rotor Amps) ~6.5 A
Relay Type PTC Relay
Capacitor Not required (RSIR design)

Electrical Configuration (RSIR System)

The GL45AN uses a Resistance Start Induction Run configuration:

  • Start winding activated via PTC relay
  • No run capacitor required
  • Thermal overload protection integrated
  • Designed for stable voltage environments

This configuration reduces component count and improves long-term reliability.


Application Examples

This compressor is suitable for:

  • Domestic refrigerators (single door)
  • Hotel minibars
  • Beverage display coolers
  • Small medical refrigerators
  • Undercounter cooling units

It is not recommended for:

  • Deep freezing below −35°C
  • High back pressure systems
  • Large commercial freezer cabinets

Performance Comparison (Same Class)

Model Refrigerant HP Displacement
ZMC GL45AN R134a 1/8 4.5 cc
Secop TLES5.7 R134a 1/6 5.7 cc
Embraco EM2X60 R134a 1/6 6.0 cc
Huayi HYE45 R134a 1/8 4.5 cc

The GL45AN offers lower energy consumption compared to higher-displacement compressors, making it ideal where efficiency and compact size are required.


Replacement Compressors – Same Refrigerant (R134a)

  1. Embraco EM2X45
  2. Secop TLES4.8
  3. Huayi HYE45
  4. Donper GFF45AA
  5. LG MA45LAEG

Replacement Compressors – Other Refrigerants (With System Modification)

  1. Embraco EGX70 (R600a)
  2. Secop TLY5.7 (R600a)
  3. Huayi HYB45 (R600a)
  4. Donper GHF50 (R600a)
  5. LG MA53LAG (R600a)

System oil, capillary, and dryer must be adapted.


Engineering Advice & Best Practices

  • Always replace the filter dryer when installing
  • Evacuate system to below 500 microns
  • Maintain condenser airflow clearance
  • Match capillary length precisely
  • Avoid overcharging; R134a is sensitive to charge quantity

Key Benefits

  • Low vibration & quiet operation
  • Proven durability in field use
  • Easy replacement compatibility
  • Stable cooling under voltage fluctuation
  • Widely available service parts

Frequently Asked Question

Can the ZMC GL45AN be used in a freezer?

Yes, it can operate in light freezing applications down to approximately −30°C evaporating temperature, provided the system is correctly sized and ventilated.


Focus Keyphrase

ZMC GL45AN compressor R134a 1/8 HP LBP refrigeration compressor for refrigerator cooling and light freezing applications replacement guide


SEO Title

ZMC GL45AN Compressor R134a 1/8 HP | Technical Specs & Replacement Guide


Meta Description

Professional guide to the ZMC GL45AN compressor: R134a, 1/8 HP, LBP refrigeration use, specifications, replacements, applications, and expert installation advice.


SEO Slug

zmc-gl45an-compressor-r134a-1-8hp


Tags

ZMC GL45AN, Compressor R134a, 1/8 HP Compressor, Refrigerator Compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GL45AN replacement, Embraco replacement, Secop replacement


Excerpt

The ZMC GL45AN is a hermetic refrigeration compressor designed for R134a systems in cooling and light freezing applications. With a 1/8 HP motor, LBP operation, and RSIR electrical design, it delivers stable performance, low noise, and high reliability for domestic and light commercial refrigeration equipment.

ZMC GL45AN Compressor – R134a, 1/8 HP, LBP mbsmpro



Excellent GS66AZ Compressor Technical Specifications, BIG 1/6 HP, 6.6 cm3

Excellent Compressor GS66AZ 1/6 HP R134a mbsmpro

Excellent Compressor GS66AZ: A Comprehensive Technical Overview and Replacement Guide

The GS66AZ is a robust and efficient hermetically sealed compressor designed for light commercial and high-demand domestic refrigeration applications. Engineered for reliability within specific thermal envelopes, this model represents a key component in sustaining consistent cooling performance. Its specifications indicate a design focused on energy efficiency and durable operation under continuous use conditions. This article provides a detailed technical breakdown, replacement guidelines, and practical insights for technicians and procurement specialists.

Complete Technical Specifications of the GS66AZ Compressor

Parameter Specification for GS66AZ
Model GS66AZ
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Low-Temperature Refrigeration
Oil Type and Quantity Polyester (POE) Oil, specific quantity as per manufacturer datasheet (typically ~350ml)
Horsepower (HP) Approximately 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V ~ 50/60Hz, 1 Phase
Cooling Capacity BTU To be confirmed from official performance curves (est. ~700-900 BTU/hr @ LBP conditions)
Motor Type RSIR (Resistance Start Induction Run)
Displacement Model-specific (refer to manufacturer data)
Winding Material Copper
Pression Charge Designed for low evaporating pressure applications
Capillary System-dependent; must be matched to the condenser and evaporator for optimal performance.
Modele Frigo/Refrigerator Compatibility Designed for low-temperature compartments in domestic refrigerators, standalone freezers, and commercial display freezers.
Temperature function Optimal performance between -30°C to -10°C evaporating temperature range.
With fan or no Typically used in fan-cooled condenser systems.
Commercial or no Yes, Light Commercial / Heavy Domestic.
Amperage in function Approx. 1.3 – 1.5 A at rated voltage and load.
LRA (Locked Rotor Amps) To be confirmed from manufacturer label (typically 6-8 times running amps).
Type of relay PTC (Positive Temperature Coefficient) Start Relay.
Capacitor or no and value No run capacitor (RSIR design). PTC relay provides starting assistance.
5 Compressor replacements of same value in same gas (R134a) GN66AZ, GE66AZ, GR66AZ, GJ66AZ, GP66AZ (Always verify model suffixes for exact electrical and mechanical compatibility).
5 Compressor replacements of same value in other gas Models designed for R600a (e.g., GN60AZ series) or R404A/R290 will have different electrical characteristics and are NOT direct drop-in replacements. System conversion required.

Deep Dive: Application and Engineering Context

The LBP (Low Back Pressure) designation is crucial. It means this compressor is engineered to pump refrigerant where the evaporator (cooling compartment) operates at a very low pressure, corresponding to the -30°C to -10°C temperature range essential for freezing. This contrasts with MBP (Medium Back Pressure) compressors used for fresh food cooling (typically -5°C to +10°C) and HBP (High Back Pressure) units for air conditioning or beverage coolers.

Comparison with Other Compressor Types

Feature GS66AZ (LBP, R134a) Typical MBP Compressor (e.g., for refrigerator section) Miniature DC Compressor (e.g., for portable fridge)
Primary Use Freezing / Deep Cooling Fresh Food Preservation Portable, 12/24V Applications
Efficiency at Low Temp High (Optimized for this duty) Poor (will overwork and fail prematurely) Low to Moderate
Typical HP 1/5 HP to 1/4 HP 1/6 HP to 1/5 HP < 1/10 HP
System Complexity Standard AC single-phase Standard AC single-phase Requires DC power/control board
Durability High (Commercial Duty) Moderate (Domestic Duty) Low to Moderate

Key Benefits and Selection Advice

  • Reliability: The RSIR motor with copper windings offers a simple, robust design well-suited for constant operation.
  • Broad Voltage Compliance: The 220-240V 50/60Hz range makes it adaptable to power standards in many regions.
  • Energy Consideration: While not an inverter model, its efficiency is optimized within its specified LBP operating window.

Critical Notices for Technicians:

  1. Oil Compatibility: POE oil is hygroscopic. Always keep the system open for a minimal time and use proper vacuum procedures to avoid moisture contamination and acid formation.
  2. Electrical Verification: Always check the actual nameplate on the unit. While the GS66AZ is common, suffixes may indicate different plug types or minor performance tweaks.
  3. Non-Direct Replacements: Swapping to a compressor using a different refrigerant (like R600a or R290) is not a simple plug-and-play. It requires changing the capillary tube, possibly the filter-drier, and ensuring correct oil charge, making it a job for qualified professionals.
  4. Overheating Protection: Ensure the original system’s overload protector and PTC relay are in good condition or replaced when installing a new compressor to prevent burnout.

Conclusion
The GS66AZ compressor is a workhorse for low-temperature refrigeration. Its value lies in its specific engineering for freezing applications, commercial-grade durability, and straightforward RSIR design. Successful implementation and replacement hinge on respecting its LBP designation, ensuring electrical compatibility, and following rigorous installation practices to ensure long system life and reliable performance.


Focus Keyphrase: GS66AZ compressor specifications R134a LBP freezing replacement commercial 220V

SEO Title: GS66AZ Compressor Specs & Replacement Guide | R134a LBP Freezing Unit | Mbsmpro.com

Meta Description: Complete technical analysis of the GS66AZ compressor. Covers specs, HP, LBP use, R134a gas, replacement models, and critical installation notices for freezer repair.

Slug: gs66az-compressor-specifications-replacement-guide

Tags: Mbsmgroup, Mbsm.prombsmpro.com, mbsm, GS66AZ, Compressor Replacement, R134a Compressor, LBP Compressor, Freezer Compressor, Commercial Refrigeration, Hermetic Compressor, GN66AZ, GE66AZ, GR66AZ

Excerpt: The GS66AZ is a robust hermetically sealed compressor designed for light commercial and domestic freezing applications. This guide provides full technical specifications, including its LBP use for…


Excellent Compressor GS66AZ 1/6 HP R134a mbsmpro
1/6 HP, EMT56HLP, Excellent, GL60AA, GQR60AA, GS66AZ, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, OF1033A, QD65H, R134a, Refrigeration Repair



Defrost Timer Module

Defrost Timer Module mbsmpro

Mbsmpro.com, Universal Electronic Defrost Timer Module, Refrigerator Control, 220-240V, 50/60Hz, 10A, Compressor Control, Defrost Cycle, Wiring Schematic, HVAC Repair

The Ultimate Guide to the Universal Electronic Defrost Timer Module: Engineering and Field Application

In the demanding world of professional refrigeration repair, adaptability is the hallmark of a master technician. When high-end electronic control boards fail and original replacements are obsolete or unavailable, the Universal Electronic Defrost Timer Module emerges as the definitive solution. This solid-state powerhouse is designed to bypass complex circuitry, providing a reliable, long-term fix for domestic and commercial cooling systems.

Technical Characteristics and Operating Principles

Unlike traditional mechanical timers that rely on a motorized gear train, this electronic module utilizes a microchip to manage timing cycles. This eliminates the risk of mechanical wear and “stuck” gears, which are the primary causes of evaporator freeze-ups.

Specification Detail / Value
Input Voltage 220V – 240V AC
Frequency 50 / 60 Hz
Maximum Current (Compressor) 10 Amps (Inductive)
Maximum Current (Defrost) 5 Amps (Resistive)
Defrost Interval Fixed 6 or 8 Hours (Model Dependent)
Defrost Duration Fixed 20 to 25 Minutes
Housing High-Insulation Heat-Shrink Polymer
Operating Temperature -10°C to +55°C

Comparison: Mechanical vs. Electronic Defrost Timers

Understanding the shift from mechanical to electronic components is vital for modernizing older units.

Feature Mechanical Timer Electronic Module
Reliability Prone to gear failure High (No moving parts)
Noise Level Audible clicking/humming Completely silent
Accuracy Varies with motor wear Digital precision
Vibration Resistance Low (Internal pins can shift) High (Solid-state encapsulation)
Size Bulky, requires mounting bracket Compact, fits inside wire looms

Advanced Wiring Schematic for Technicians

To successfully integrate this module into a refrigerator, one must identify the primary power feeds and load lines. Below is the standard industrial wiring configuration for these four-wire universal modules:

  • Line 1 (Phase): Usually connected to the Brown or Black wire.
  • Neutral (N): Connected to the Blue wire.
  • Compressor Output (Terminal 4 equivalent): Connected to the Red wire.
  • Defrost Heater Output (Terminal 2 equivalent): Connected to the Orange wire.

Engineer’s Note: Always verify the color coding with a multimeter before final soldering, as some manufacturers may swap the Orange and Red functions depending on the production batch.

Installation Strategy and Field Advice

When performing a “board bypass,” the objective is to restore the basic cooling logic: Compressor Run -> Accumulated Time -> Defrost Cycle -> Repeat.

  1. Thermal Protection: Ensure the defrost heater circuit remains in series with the original Bimetal Thermostat and Thermal Fuse. Never bypass safety components.
  2. Placement: Although encapsulated, avoid placing the module in areas prone to direct moisture or heavy vibration from the compressor.
  3. Connection Integrity: Use high-quality crimp connectors or solder with heat-shrink tubing to prevent oxidation in high-humidity environments.

Benefits of Using the Universal Electronic Module

  • Versatility: Compatible with almost all non-inverter brands including LG, Samsung, Whirlpool, and Daewoo.
  • Durability: The solid-state design handles voltage fluctuations better than traditional mechanical motors.
  • Compact Design: Its slim profile allows it to be tucked away inside the compressor compartment or the rear wiring panel.

Focus Keyphrase: Mbsmpro.com Universal Electronic Defrost Timer Module Wiring Schematic and Refrigerator Repair Guide for Technicians

SEO Title: Mbsmpro.com | Universal Electronic Defrost Timer | Wiring & Specs

Meta Description: Master the installation of the Universal Electronic Defrost Timer Module. Includes wiring schematics, technical specs, and professional HVAC repair advice.

Slug: universal-electronic-defrost-timer-wiring-schematic-mbsmpro

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Refrigerator Repair, Defrost Timer, HVAC Engineering, Solid State Control, Cooling System Modification, Compressor Wiring

Excerpt: The Universal Electronic Defrost Timer Module is a critical component for modernizing refrigerator repairs. Designed to replace failing mechanical timers and expensive control boards, this solid-state device offers unmatched reliability. Featuring a 220V input and 10A capacity, it ensures precise timing for compressor operation and defrost cycles in various domestic refrigeration brands.


Defrost Timer Module mbsmpro
Defrost Timer Module mbsmpro



Compressor, Matsushita, D77C18RAX5, 1/4 hp, Panasonic

Compressor, Matsushita, D77C18RAX5, 1/4 hp, Panasonic mbsmpro

Mbsmpro.com, Compressor, Matsushita, D77C18RAX5, 1/4 hp, Panasonic, Cooling, R134a, 195 W, 1.4 A, 1Ph 220V 50Hz, LBP, RSIR, −35°C to −10°C, Household Refrigerator

The refrigeration industry has seen many legends, but few names carry as much weight in the workshop as Matsushita—the manufacturing powerhouse now known globally as Panasonic. Among their most reliable workhorses is the D77C18RAX5 compressor. This hermetic reciprocating unit has been the backbone of thousands of residential refrigerators and commercial chest freezers, prized for its “set it and forget it” reliability.

Engineering Excellence: The D77C18RAX5 Architecture

The D77C18RAX5 is a Low Back Pressure (LBP) compressor designed specifically to handle the rigors of deep freezing and standard refrigeration. Built in Malaysia under strict quality controls, this model utilizes a 7.7cc displacement to move R134a refrigerant efficiently through the system.

From an engineering perspective, the “D77” series is celebrated for its high volumetric efficiency and robust thermal protection. Unlike modern inverter compressors that require complex electronic control boards, the D77C18RAX5 relies on a tried-and-true RSIR (Resistive Start, Inductive Run) motor. This makes it exceptionally resilient to voltage fluctuations often found in older residential grids.

Technical Specifications Table

Feature Specification
Model D77C18RAX5
Manufacturer Matsushita (Panasonic)
Refrigerant Type R134a
Horsepower (HP) 1/4 HP
Displacement 7.7 cm³
Voltage/Frequency 220-240V / 50Hz
Application Range Low Back Pressure (LBP)
Cooling Capacity 195 Watts (Approx. 665 BTU/h)
Motor Type RSIR
Starting Current (LRA) 11.5 A
Running Current 1.3 – 1.5 A
Oil Type POE (Polyolester)
Cooling Method Static (Natural Convection)

Performance Comparison: R134a vs. R600a Variants

In the modern landscape, there is a push toward R600a (isobutane). However, the D77C18RAX5 remains a critical component for repairs because of its specific pressure-temperature relationship. When compared to an R600a equivalent, the D77 series offers higher mass flow rates, which is essential for older cabinet designs with smaller evaporator surface areas.

Metric Matsushita D77C18RAX5 (R134a) Typical R600a 1/4 HP Equivalent
Displacement 7.7cc 11.0cc to 12.0cc
Pressure Levels Higher Discharge Pressures Lower (Vacuum-prone)
Reliability Proven 15-20 year lifespan High (but sensitive to moisture)
Lubrication POE Oil (Hygroscopic) Mineral Oil

Expert Insight: Field Service Tips

When replacing this unit, field technicians must prioritize the evacuation process. Since the D77C18RAX5 uses POE oil, any moisture left in the system can react to form acids that eat away at the motor windings.

  1. Always replace the Filter Drier: Never install a new D77 without a fresh XH-9 or universal drier.
  2. Verify the Capacitor: While most are RSIR, some variations use a starting capacitor to assist in high-ambient starts. Check the relay housing before installation.
  3. Heat Management: Ensure the condenser coils are cleaned. The D77 is thermally protected, but frequent cycling due to heat buildup will eventually degrade the internal valves.

Detailed Compressor Data Sheet

Model D77C18RAX5
Utilisation (mbp/hbp/lbp) LBP
Domaine (Freezing/Cooling) Domestic Freezing / Refrigerator Cooling
Oil Type and quantity POE 230ml
Horsepower (HP) 1/4 HP
Refrigerant Type R134a
Power Supply 220V-240V ~ 50Hz
Cooling Capacity BTU 665 BTU/h
Motor Type RSIR
Displacement 7.7 cc
Winding Material Copper
Pression Charge Low side: 0.5 – 2 PSI (Running)
Capillary Recommendation 0.031″ or 0.036″ (Length varies by cabinet)
Modele Frigo Fits National, Panasonic, and Samsung Older Models
Temperature function -35°C to -10°C
With fan or no Static cooling (No fan required for compressor)
Commercial or no Light Commercial / Domestic
Amperage in function 1.4 A
LRA (Locked Rotor Amps) 11.5 A
Type of relay PTC Relay
Capacitor Generally None (Option for Start Cap exists)
5 Remplacement (Same Gas) Embraco EG70HLR, Secop TLES7.5KK.3, Donper QD75, LG MA72LAEG, ACC GVY75AA
5 Remplacement (Other Gas) Secop TLY8.7KK (R600a), Embraco EMX70CLC (R600a), Cubigel GL80AA (R134a/R600a conversion), Jiaxipera NT1114Y, Nidec TT1114GY

Benefits of the D77C18RAX5

  • Thermal Protection: Built-in overload protector prevents motor burnout during brownouts.
  • Low Vibration: The internal spring mounting system is designed for ultra-quiet household operation.
  • Global Standard: Parts like relays and overloads are universally available, making maintenance simple anywhere in the world.

Engineering Notice: If you find this compressor running hot but not cooling, check the discharge pressure. These units are extremely durable, but if the valves are bypassed due to liquid slugging, the efficiency drops significantly. Always ensure the refrigerant charge is weighed in according to the appliance nameplate.


Focus Keyphrase: Matsushita D77C18RAX5 Compressor 1/4 HP R134a Specifications and Replacement Guide

SEO Title: Mbsm.pro – Matsushita D77C18RAX5 Compressor | 1/4 HP | R134a | LBP Specs

Meta Description: Discover the technical specifications of the Matsushita D77C18RAX5 compressor. A professional guide to 1/4 HP R134a cooling capacity, amperage, and reliable replacements.

Slug: matsushita-d77c18rax5-compressor-1-4-hp-r134a-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Matsushita, Panasonic, D77C18RAX5, 1/4 HP, R134a, LBP, Refrigerator Compressor, EG70HLR replacement, QD75 replacement, TLES7.5KK.3 replacement, MA72LAEG replacement, GVY75AA replacement.

Excerpt: The Matsushita D77C18RAX5 is a legendary 1/4 HP refrigerator compressor optimized for R134a refrigerant. Known for its robust RSIR motor and 7.7cc displacement, it delivers 195W of cooling power for domestic freezers and refrigerators. This guide provides full technical data, wiring details, and the best professional cross-reference replacements for modern refrigeration repair.

Compressor, Matsushita, D77C18RAX5, 1/4 hp, Panasonic mbsmpro
Compressor, Matsushita, D77C18RAX5, 1/4 hp, Panasonic mbsmpro



Huayi HYE69Y63 Compressor 1/5 HP R134a LBP

Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro

Focus Keyphrase: Huayi HYE69Y63 Compressor 1/5 HP R134a LBP Technical Specifications and Professional Cross-Reference Guide for Refrigerator Repair

SEO Title: Mbsmpro.com, Compressor, HYE69Y63, 1/5 hp, Huayi, Cooling, R134a, 168 W, 1.2 A, 1Ph 220-240V 50/60Hz, LBP, RSIR, -35°C to -10°C, freezing

Meta Description: Technical analysis of the Huayi HYE69Y63 1/5 HP compressor. Learn about its R134a performance, LBP cooling capacity, electrical wiring schemas, and top 10 replacement alternatives for technicians.

Slug: huayi-hye69y63-compressor-r134a-1-5-hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYE69Y63, R134a, 1/5 HP, LBP, Refrigerator Repair, HVAC, GL70AA, EMT55HLP, PE75H1C, PL50F, FFI6HAK, NTU170MT, HMK12AA, HTK12AA, HYB12MHU, NT1114Y

Excerpt: The Huayi HYE69Y63 is a highly efficient hermetic reciprocating compressor designed for low back pressure applications using R134a refrigerant. With a 1/5 HP rating and dual-frequency compatibility (50/60Hz), this motor is a cornerstone for domestic refrigerators and freezers. This comprehensive guide covers technical datasheets, electrical wiring, and professional replacement strategies for global cooling systems.


Mastering Domestic Refrigeration: The Technical Profile of the Huayi HYE69Y63 Compressor

In the precision-driven world of refrigeration engineering, the Huayi HYE69Y63 stands as a testament to reliable, small-scale thermal management. As a 1/5 horsepower unit optimized for Low Back Pressure (LBP) cycles, this compressor is a frequent choice for manufacturers of domestic refrigerators and light-duty freezers. Its ability to operate across both 50Hz and 60Hz frequencies makes it a versatile global component, capable of maintaining sub-zero temperatures with impressive volumetric efficiency.

Engineering Design and Performance

The HYE69Y63 utilizes a hermetic reciprocating mechanism, engineered to move R134a refrigerant with minimal mechanical friction. In the field, technicians value this model for its thermal protection systems and robust winding material, which ensure longevity even in high-ambient temperature environments. The “HYE” series from Huayi is recognized for its low noise profile and vibration-damping housing, making it ideal for residential kitchen appliances.

Technical Data and Specifications Table

Feature Detailed Specification
Model HYE69Y63
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Cold Storage
Oil Type and Quantity POE (Ester Oil) – Approx. 180 ml
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240VAC / 50-60Hz / 1 Phase
Cooling Capacity (ASHRAE) 168 Watts / 573 BTU/h (@ -23.3°C)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 6.9 cm³
Winding Material High-Grade Copper
Pressure Charge 0.8 to 1.3 Bar (Evaporating Pressure)
Capillary Recommendation 0.031″ ID (Length dependent on cabinet)
Refrigerator Brands Haier, Whirlpool, Midea, Hisense
Temperature Function -35°C to -10°C (-31°F to 14°F)
Cooling System Static (Natural Convection)
Commercial Class Domestic / Residential
Amperage (FLA) 1.1 A to 1.3 A
LRA (Locked Rotor Amps) 12.0 A
Type of Relay PTC (Positive Temperature Coefficient)
Capacitor Requirement Generally none (Standard RSIR configuration)

Electrical Wiring Schema (RSIR Configuration)

Correct electrical connection is paramount for the safety of the hermetic motor. The terminal block of the HYE69Y63 follows the standard triangular pin layout:

Common (C): Located at the top of the triangle. This connects to the line supply through the Thermal Overload Protector.
Main/Run (M): Located at the bottom right. This winding remains energized throughout the cooling cycle.
Start (S): Located at the bottom left. This winding is energized momentarily via the PTC relay to initiate rotation.

Technician’s Insight: If the compressor fails to start but hums, check the resistance between C-M and C-S. A healthy motor will show a combined resistance across S-M that equals the sum of the two individual readings.


Comparative Performance Analysis

When comparing the HYE69Y63 against its industry peers, we see a focus on balancing displacement with energy consumption.

Metric Huayi HYE69Y63 (R134a) Standard 1/5 HP (R600a Equivalent)
Displacement 6.9 cm³ 10.2 cm³
Operating Pressure Positive (Standard) Low / Near-Vacuum
Efficiency (COP) 1.30 W/W 1.50 W/W
Gas Charge Weight Moderate (~120g) Low (~50g)

Professional Replacement Cross-Reference

Finding a suitable replacement requires matching the BTU/h capacity and the displacement as closely as possible to maintain the refrigerator’s original duty cycle.

5 Compressor Replacements (R134a – Same Gas):

  1. Embraco: EMT55HLP (High performance, near-identical BTU)
  2. ACC / Cubigel: GL70AA (Robust European alternative)
  3. GMCC: PE75H1C (Slightly higher displacement, very reliable)
  4. Secop (Danfoss): PL50F (Compact design for limited spaces)
  5. Tecumseh: FFI6HAK (Standard American replacement)

5 Compressor Replacements (R600a – Different Gas):
Note: Converting from R134a to R600a requires a complete system flush, oil replacement, and potentially a capillary tube adjustment.

  1. TEE: NTU170MT
  2. Cubigel: HMK12AA
  3. Secop: HTK12AA
  4. Huayi: HYB12MHU
  5. Jiaxipera: NT1114Y

Field Engineering Advice and Notices

  • Vacuum Standards: Because R134a systems use POE oil, they are highly sensitive to moisture. A deep vacuum of at least 500 microns is mandatory. Failure to achieve this will lead to acid formation, which destroys the motor windings over time.
  • Thermal Protection: If the compressor “clicks” off frequently, ensure the condenser coils are clean. Static-cooled compressors like the HYE69Y63 rely on natural convection; dust buildup can cause the internal thermal protector to trip prematurely.
  • Start Components: Always replace the PTC relay and the overload protector when installing a new compressor. A fatigued relay can cause the start winding to stay energized too long, leading to a catastrophic burnout of the new unit.
  • Charging by Weight: For R134a, always charge using a digital scale to the exact weight specified on the refrigerator’s nameplate. Charging by “pressure feel” often leads to overcharging, which increases the stress on the 1/5 HP motor.

Conclusion and Practical Benefits

The Huayi HYE69Y63 is a resilient, mid-range compressor that provides a stable cooling solution for millions of households worldwide. For the engineer, it represents a standard “plug-and-play” solution for a wide variety of refrigeration brands. Its dual-frequency capability and high copper-content windings make it an exceptionally forgiving unit in regions where power grid stability may fluctuate.

Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro
Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro



Huayi HYB60MGU Compressor 1/7 HP R600a LBP

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro

Focus keyphrase: Huayi HYB60MGU Compressor 1/7 HP R600a LBP Technical Specifications Wiring Diagram and Professional Replacement Guide for Domestic Refrigeration Systems

SEO Title: Mbsmpro.com, Compressor, Huayi, HYB60MGU, 1/7 hp, R600a, 110 W, 0.55 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, cooling or freezing

Meta Description: Technical datasheet for the Huayi HYB60MGU compressor. Explore its 1/7 HP capacity, R600a efficiency, electrical wiring schemas, and professional cross-reference replacements.

Slug: huayi-hyb60mgu-compressor-r600a-1-7hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYB60MGU, R600a, 1/7 HP, LBP, Compressor Replacement, EMT45HDR, TLES5.7KK.3, T1112Y, A60CY, ETA60, GL60AA, EMI45HER, TLS5F, B30H

Excerpt: The Huayi HYB60MGU is a high-efficiency hermetic reciprocating compressor specifically engineered for Low Back Pressure (LBP) applications. Operating on the eco-friendly R600a refrigerant, this 1/7 HP unit is a primary component in modern household refrigerators. This guide provides an in-depth technical analysis, electrical wiring configurations, and reliable replacement alternatives for field engineers.


The Engineering Behind the Huayi HYB60MGU: A Technical Standard in R600a Cooling

In the contemporary landscape of domestic refrigeration, the Huayi HYB60MGU represents a cornerstone of energy-efficient design. As a professional who has spent years troubleshooting and installing these units, it is clear that Huayi has optimized the HYB series to meet the rigorous European and international standards for low-temperature performance.

This compressor is a hermetic reciprocating type, designed for Low Back Pressure (LBP) cycles. Its integration of R600a (isobutane) not only aligns with global environmental mandates but also provides superior thermodynamic efficiency compared to legacy R134a systems. For technicians, understanding the mechanical and electrical nuances of the HYB60MGU is essential for ensuring system longevity.

Technical Data Sheet: Huayi HYB60MGU

Feature Specification
Model HYB60MGU
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigerators / Freezers
Oil Type and Quantity Mineral Oil / 180 ml
Horsepower (HP) 1/7 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1 Phase
Cooling Capacity BTU 375 BTU/h (approx. 110 Watts)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 6.0 cm³
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Standard LBP operation)
Capillary Recommendation 0.026″ – 0.028″ ID (Varies by cabinet)
Application Range -35°C to -10°C
Cooling System Static (Natural convection)
Commercial Classification Residential / Household
Amperage (Running) 0.55 A – 0.7 A
LRA (Locked Rotor Amperage) 4.8 A
Type of Relay PTC (Positive Temperature Coefficient)
Capacitor Requirement None (RSIR Configuration)

Electrical Wiring Schema (RSIR Configuration)

The terminal housing of the Huayi HYB60MGU follows a standard triangular pin configuration which is critical for proper startup and protection.

Schema Description:

  • Common (C): The apex pin. This pin connects to the Thermal Overload Protector (OLP), which monitors the motor temperature and current draw.
  • Start (S): The pin usually on the right side. It is momentarily energized by the PTC relay to initiate rotation.
  • Main/Run (M): The pin on the left side. This winding remains energized throughout the operation of the compressor.

Wiring Logic:
Line (Hot) -> Overload Protector -> Common Pin
Neutral -> PTC Relay -> Main Pin & Start Pin

Engineering Note: Always verify the resistance between C-S and C-M. The sum of these two measurements should roughly equal the resistance across S-M. Any significant deviation indicates a winding fault.


Comparative Efficiency: R600a vs. R134a Models

When evaluating the HYB60MGU, it is helpful to compare it against similarly rated R134a compressors to understand the benefits of the modern R600a cycle.

Metric Huayi HYB60MGU (R600a) Standard 1/7 HP (R134a)
Operating Pressure Low / Vacuum High Positive
Displacement 6.0 cm³ 4.5 cm³
Energy Consumption Low (High COP) Moderate
Environment GWP < 3 (Eco-friendly) GWP 1430 (Global Warming)

Professional Replacement Cross-Reference

In repair scenarios where the exact Huayi model is unavailable, these alternatives provide the same cooling capacity and displacement.

5 Replacements in R600a (Same Gas):

  1. Embraco: EMT45HDR (High-reliability alternative)
  2. Secop (Danfoss): TLES5.7KK.3 (Common European replacement)
  3. Jiaxipera: T1112Y (Found in many Beko/Haier units)
  4. Donper: A60CY
  5. Wanbao: ETA60

5 Replacements in R134a (Conversion Required):
Note: Converting from R600a to R134a requires a full system flush and capillary resizing.

  1. Zem: GL60AA
  2. Embraco: EMI 45HER
  3. Secop: TLS5F
  4. Huayi: B30H
  5. Cubigel: GL60AA

Field Engineering Advice and Notices

  • Vacuuming Procedure: Because R600a systems operate at very low pressures, moisture is a catastrophic contaminant. Always pull a vacuum down to at least 200 microns before charging.
  • Charging by Weight: R600a is highly sensitive to overcharging. Always use a digital scale and charge precisely to the manufacturer’s specification (usually 40-60 grams). Do not charge by pressure.
  • Flammability Safety: R600a is isobutane. Ensure no open flames are nearby during charging or discharging. Use “Lokring” cold connections if you are not in a controlled, ventilated environment for brazing.
  • Overload Protection: If the compressor “clicks” but fails to start, check the PTC relay first. These components are prone to cracking due to heat cycles.

Conclusion and Professional Benefit

The Huayi HYB60MGU is a resilient unit that, when maintained correctly, offers years of silent and efficient operation. Its low running amperage makes it an ideal choice for off-grid or solar-powered refrigeration setups where energy conservation is paramount. For the service technician, its standard footprint and predictable electrical behavior make it a preferred model in the field.

Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro
Huayi HYB60MGU Compressor 1/7 HP R600a LBP mbsmpro



GMCC PE75H1C Compressor 1/4 HP R134a LBP

GMCC PE75H1C Compressor 1/4 HP R134a LBP mbsmpro

Focus keyphrase: GMCC PE75H1C Compressor 1/4 HP R134a LBP Technical Specifications Wiring Diagram and Replacement Cross-Reference Guide

SEO title: Mbsmpro.com, Compressor, GMCC, PE75H1C, 1/4 hp, R134a, 185 W, 1.2 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, freezing

Meta description: Professional technical analysis of the GMCC PE75H1C compressor. High-efficiency 1/4 HP LBP unit for R134a refrigeration. View wiring schemas, performance tables, and compatible replacements.

Slug: gmcc-pe75h1c-compressor-r134a-1-4-hp-lbp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GMCC, PE75H1C, R134a, 1/4 HP, LBP, Refrigerator Compressor, HVAC, GL90AA, EMT6170Z, FFI7.5HAK, NL7F, NTU170MT, HMK12AA, HTK12AA, HYB12MHU, NT1114Y

Excerpt: The GMCC PE75H1C is a robust hermetic reciprocating compressor engineered for low back pressure applications using R134a refrigerant. Operating at 220-240V 50Hz, this 1/4 HP motor provides a cooling capacity of approximately 185W. This article provides technical datasheets, electrical wiring schemas, and professional cross-reference guides for global refrigeration maintenance and engineering.


Engineering Excellence: The GMCC PE75H1C Hermetic Compressor for R134a Systems

In the world of thermal management and domestic refrigeration, the GMCC PE75H1C stands as a benchmark for reliability and volumetric efficiency. Manufactured by Anhui Meizhi Compressor Co., Ltd (a Midea Group venture), this unit is a staple in high-performance household refrigerators and chest freezers. As an engineer who has worked extensively on the field, I can attest that the “PE” series represents a balance between compact mechanical design and thermal endurance.

This compressor is designed for Low Back Pressure (LBP) cycles, making it ideal for freezing applications where evaporation temperatures drop significantly below zero. Utilizing R134a, it remains a common choice for technicians servicing existing infrastructure where synthetic oils are standard.

Detailed Technical Specifications

Feature Specification
Model PE75H1C
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Cold
Oil Type and quantity POE (Ester Oil) – Approx. 180 ml
Horsepower (HP) 1/4 HP
Refrigerant Type R134a
Power Supply 220-240V ~ 50Hz / 1 Phase
Cooling Capacity BTU 631 BTU/h (approx. 185W)
Motor Type RSIR (Resistive Start – Inductive Run)
Displacement 7.5 cm³
Winding Material High-Grade Copper
Pression Charge 0.8 to 1.3 Bar (Low side)
Capillary 0.031″ or 0.8mm ID
Refrigerator Models Midea, Toshiba, Samsung, various local brands
Temperature function -35°C to -10°C
With fan or no Static Cooling (No fan required)
Commercial or no Domestic / Light Commercial
Amperage in function 0.9 A to 1.2 A
LRA (Locked Rotor Amps) 11.0 A
Type of relay PTC Starter
Capacitor or no No (Standard RSIR)

Electrical Wiring Schema (RSIR Logic)

For field technicians, identifying the terminal pins is critical to prevent accidental motor burnout. The GMCC PE75H1C follows the standard triangular layout:

  1. C (Common): The apex pin. Connected to the line voltage through the internal Thermal Overload Protector.
  2. M (Main/Run): Bottom-right pin. Connected to the Neutral line.
  3. S (Start): Bottom-left pin. Connected via the PTC (Positive Temperature Coefficient) relay.

Operational Logic: Upon startup, the PTC relay allows current to flow to the Start winding. As the PTC heats up, its resistance increases dramatically, effectively cutting off the Start winding once the motor reaches sufficient RPM, leaving only the Main winding energized.


Performance Comparison: GMCC PE75H1C vs. Industry Standards

When comparing the PE75H1C to other compressors in the same class, we look at the Coefficient of Performance (COP) and displacement efficiency.

Metric GMCC PE75H1C (R134a) Equivalent R600a Model
Gas Displacement 7.5 cm³ 11.2 cm³
Efficiency (W/W) 1.25 1.45
Charge Weight Standard (120g – 150g) Low (40g – 60g)
Pressure Delta Moderate Low

Professional Replacement Cross-Reference

Choosing the right replacement is vital for maintaining the refrigerator’s original thermal balance.

5 Compressor replacements in same value (R134a):

  1. Zem/ACC: GL90AA
  2. Embraco: EMT6170Z or FFI 7.5HAK
  3. Secop (Danfoss): NL7F
  4. Huayi: AE1380Y
  5. Tecumseh: THB1375YSS

5 Compressor replacements in same value (R600a Conversion):
Notice: Conversion requires a full system flush and capillary adjustment.

  1. TEE: NTU170MT
  2. Cubigel: HMK12AA
  3. Secop: HTK12AA
  4. Huayi: HYB12MHU
  5. Jiaxipera: NT1114Y

Engineering Advice and Best Practices

  • Thermal Protection: The “Thermally Protected” label indicates an internal bimetallic switch. If the compressor stops and feels extremely hot, do not force a restart. Let it cool for 30 minutes. Check the condenser coils for dust; poor airflow is the primary killer of the PE75H1C.
  • Oil Compatibility: This unit uses POE (Polyolester) oil. Never mix mineral oil (MO) with this system. If you are retrofitting, ensure the system is flushed with nitrogen to remove moisture, as POE oil is highly hygroscopic.
  • Vacuum Standards: For R134a systems, reaching a vacuum of at least 500 microns is non-negotiable. Residual moisture reacts with R134a and POE oil to create acid, which will eventually dissolve the copper windings.
  • Startup Amperage: If the compressor draws high amperage (above 5A) and trips the protector, first replace the PTC relay. These components degrade over time and are a common point of failure before the motor itself fails.

Benefits of the GMCC PE75H1C

The primary benefit of this model is its durability in tropical climates. The motor is wound with high-quality copper that resists heat better than aluminum alternatives. Its compact footprint also makes it versatile for a wide range of refrigerator brands, simplifying inventory for HVAC professionals.

GMCC PE75H1C Compressor 1/4 HP R134a LBP mbsmpro
GMCC PE75H1C Compressor 1/4 HP R134a LBP mbsmpro



TEE NTU 170 MT Compressor 1/4 HP R600a

TEE NTU 170 MT Compressor 1/4 HP R600a mbsmpro

Focus Keyphrase: TEE NTU 170 MT Compressor 1/4 HP R600a Low Back Pressure Technical Specifications and Replacement Guide

SEO Title: Mbsmpro.com, Compressor, NTU 170 MT, 1/4 hp, TEE, Cooling, R600a, 204 W, 0.9 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C

Meta Description: Technical analysis of the TEE NTU 170 MT compressor. Discover 1/4 HP power specs, R600a efficiency, LBP cooling capacity, wiring diagrams, and cross-reference replacement charts.

Slug: compressor-tee-ntu170mt-r600a-1-4-hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, TEE, Turk Elektrik, NTU 170 MT, R600a, 1/4 HP Compressor, LBP, Refrigerator Repair, HVAC Engineering, EMT2121U, HTK12AA, HMK12AA, NT1114Y, HYB12MHU, GL90AA, FFI7.5HAK, NL7F

Excerpt: The TEE NTU 170 MT is a high-efficiency hermetic reciprocating compressor designed for low back pressure applications using R600a refrigerant. Known for its reliability in household refrigeration, this unit operates at 220-240V 50Hz. This article explores its technical specs, cooling capacity, and suitable replacements for HVAC technicians and engineers worldwide.


The Engineering Excellence of the TEE NTU 170 MT: A Deep Dive into R600a Refrigeration

In the evolving world of domestic refrigeration, efficiency and environmental impact are the primary drivers of innovation. The TEE NTU 170 MT, manufactured by Turk Elektrik, stands as a testament to these principles. As a Low Back Pressure (LBP) compressor optimized for R600a (isobutane), this model has become a staple in modern household refrigerators and freezers across Europe and the Middle East.

Understanding the NTU 170 MT Architecture

The NTU 170 MT is engineered to handle the unique thermodynamic properties of R600a. Unlike older R134a systems, R600a operates at lower pressures but requires a larger displacement to achieve comparable cooling capacities. This compressor utilizes a robust motor designed for RSIR (Resistive Start – Inductive Run) operation, ensuring a reliable start even under varying voltage conditions typically found in domestic environments.

The “MT” series is specifically calibrated for high-performance cooling while maintaining a low noise floor. With a Locked Rotor Amperage (LRA) of 14A, it demonstrates significant starting torque, which is essential for overcoming the initial pressures of the refrigeration cycle after a defrost period.

Technical Specification Table

Feature Specification
Model NTU 170 MT
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Deep Cooling
Oil Type and Quantity Mineral Oil (approx. 180 ml)
Horsepower (HP) 1/4 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240VAC / 50Hz / 1Ph
Cooling Capacity BTU ~700 BTU/h (at -23.3°C Evaporating Temp)
Motor Type RSIR
Displacement 11.20 cc
Winding Material High-Grade Copper
Pression Charge 0.5 to 1.2 Bar (Low side depending on load)
Capillary Recommendation 0.031″ ID x 3 meters (approximate)
Temperature Function -35°C to -10°C
Cooling System Static (No fan required for compressor)
Commercial Class Domestic / Light Commercial
Amperage (FLA) 0.8 A – 1.0 A
LRA (Locked Rotor) 14 A
Relay Type PTC Starter
Capacitor Not required (RSIR), Optional Run Cap for CSIR conversion

Electrical Wiring Schema (RSIR Configuration)

For field technicians, understanding the terminal configuration is vital. The TEE NTU 170 MT follows the standard triangular pin layout:

  1. Common (C): Top pin (typically connected to the overload protector).
  2. Start (S): Right pin (connected to the PTC relay for starting).
  3. Main/Run (M): Left pin (connected to the neutral line).

Schema Logic:
[Line] -> [Overload Protector] -> [Common Pin]
[Neutral] -> [PTC Relay] -> [Main Pin] & [Start Pin (Momentary)]

Performance Comparison: R600a vs. R134a Equivalents

When comparing the NTU 170 MT to R134a units of similar horsepower, several differences emerge. The R600a model offers a superior Coefficient of Performance (COP).

Metric TEE NTU 170 MT (R600a) Equivalent R134a Model (e.g., GL90AA)
Efficiency (COP) 1.45 – 1.55 W/W 1.20 – 1.35 W/W
Operating Pressure Low / Vacuum High
Eco-Impact GWP 3 (Low) GWP 1430 (High)
Noise Level Very Low Moderate

Compatibility and Replacement Guide

Finding a direct replacement requires matching the displacement and the LBP characteristic. Below are the recommended alternatives for the NTU 170 MT.

Top 5 Replacements (R600a – Same Gas):

  1. Embraco: EMT2121U
  2. Secop (Danfoss): HTK12AA
  3. ACC / Cubigel: HMK12AA
  4. Jiaxipera: NT1114Y
  5. Huayi: HYB12MHU

Top 5 Replacements (R134a – Conversion Required):
Note: Converting from R600a to R134a requires a full system flush, capillary adjustment, and oil compatibility check.

  1. Zem: GL90AA
  2. Embraco: FFI 7.5HAK
  3. Secop: TLES7.5KK.3
  4. Tecumseh: THB1375YSS
  5. Carlyle: S26SC

Engineering Notices and Maintenance Tips

  • Vacuuming Procedure: Due to the hygroscopic nature of the systems and the low pressures of R600a, a deep vacuum (minimum 200 microns) is mandatory. R600a systems are highly sensitive to non-condensables.
  • Charging Safety: R600a is flammable. Always ensure the work area is well-ventilated. Use a dedicated electronic scale, as the charge weight is significantly lower than R134a (often only 40-60 grams).
  • Filter Drier: Always replace the filter drier with one specifically labeled for R600a (XH-9 or equivalent) during any compressor swap.
  • Capillary Blockage: Because R600a operates at lower discharge temperatures, carbonization is rare, but moisture-related ice blockages are common if the system is not perfectly dry.

Benefits for the End-User

Using a TEE NTU 170 MT ensures the refrigerator operates with minimal energy consumption. For the homeowner, this translates to lower electricity bills and a quieter kitchen environment. For the technician, the wide availability of parts for the TEE/Arçelik ecosystem makes it a preferred choice for long-term maintenance.

TEE NTU 170 MT Compressor 1/4 HP R600a mbsmpro
TEE NTU 170 MT Compressor 1/4 HP R600a mbsmpro