Technical data, tools and notes for refrigeration and electronics technicians.

Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro
18, Jan 2026
Huayi HYE69Y63 Compressor 1/5 HP R134a LBP
image_pdfimage_print

Focus Keyphrase: Huayi HYE69Y63 Compressor 1/5 HP R134a LBP Technical Specifications and Professional Cross-Reference Guide for Refrigerator Repair

SEO Title: Mbsmpro.com, Compressor, HYE69Y63, 1/5 hp, Huayi, Cooling, R134a, 168 W, 1.2 A, 1Ph 220-240V 50/60Hz, LBP, RSIR, -35°C to -10°C, freezing

Meta Description: Technical analysis of the Huayi HYE69Y63 1/5 HP compressor. Learn about its R134a performance, LBP cooling capacity, electrical wiring schemas, and top 10 replacement alternatives for technicians.

Slug: huayi-hye69y63-compressor-r134a-1-5-hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Huayi, HYE69Y63, R134a, 1/5 HP, LBP, Refrigerator Repair, HVAC, GL70AA, EMT55HLP, PE75H1C, PL50F, FFI6HAK, NTU170MT, HMK12AA, HTK12AA, HYB12MHU, NT1114Y

Excerpt: The Huayi HYE69Y63 is a highly efficient hermetic reciprocating compressor designed for low back pressure applications using R134a refrigerant. With a 1/5 HP rating and dual-frequency compatibility (50/60Hz), this motor is a cornerstone for domestic refrigerators and freezers. This comprehensive guide covers technical datasheets, electrical wiring, and professional replacement strategies for global cooling systems.


Mastering Domestic Refrigeration: The Technical Profile of the Huayi HYE69Y63 Compressor

In the precision-driven world of refrigeration engineering, the Huayi HYE69Y63 stands as a testament to reliable, small-scale thermal management. As a 1/5 horsepower unit optimized for Low Back Pressure (LBP) cycles, this compressor is a frequent choice for manufacturers of domestic refrigerators and light-duty freezers. Its ability to operate across both 50Hz and 60Hz frequencies makes it a versatile global component, capable of maintaining sub-zero temperatures with impressive volumetric efficiency.

Engineering Design and Performance

The HYE69Y63 utilizes a hermetic reciprocating mechanism, engineered to move R134a refrigerant with minimal mechanical friction. In the field, technicians value this model for its thermal protection systems and robust winding material, which ensure longevity even in high-ambient temperature environments. The “HYE” series from Huayi is recognized for its low noise profile and vibration-damping housing, making it ideal for residential kitchen appliances.

Technical Data and Specifications Table

FeatureDetailed Specification
ModelHYE69Y63
Utilisation (mbp/hbp/lbp)LBP (Low Back Pressure)
Domaine (Freezing/Cooling)Freezing / Deep Cold Storage
Oil Type and QuantityPOE (Ester Oil) – Approx. 180 ml
Horsepower (HP)1/5 HP
Refrigerant TypeR134a
Power Supply220-240VAC / 50-60Hz / 1 Phase
Cooling Capacity (ASHRAE)168 Watts / 573 BTU/h (@ -23.3°C)
Motor TypeRSIR (Resistive Start – Inductive Run)
Displacement6.9 cm³
Winding MaterialHigh-Grade Copper
Pressure Charge0.8 to 1.3 Bar (Evaporating Pressure)
Capillary Recommendation0.031″ ID (Length dependent on cabinet)
Refrigerator BrandsHaier, Whirlpool, Midea, Hisense
Temperature Function-35°C to -10°C (-31°F to 14°F)
Cooling SystemStatic (Natural Convection)
Commercial ClassDomestic / Residential
Amperage (FLA)1.1 A to 1.3 A
LRA (Locked Rotor Amps)12.0 A
Type of RelayPTC (Positive Temperature Coefficient)
Capacitor RequirementGenerally none (Standard RSIR configuration)

Electrical Wiring Schema (RSIR Configuration)

Correct electrical connection is paramount for the safety of the hermetic motor. The terminal block of the HYE69Y63 follows the standard triangular pin layout:

Common (C): Located at the top of the triangle. This connects to the line supply through the Thermal Overload Protector.
Main/Run (M): Located at the bottom right. This winding remains energized throughout the cooling cycle.
Start (S): Located at the bottom left. This winding is energized momentarily via the PTC relay to initiate rotation.

Technician’s Insight: If the compressor fails to start but hums, check the resistance between C-M and C-S. A healthy motor will show a combined resistance across S-M that equals the sum of the two individual readings.


Comparative Performance Analysis

When comparing the HYE69Y63 against its industry peers, we see a focus on balancing displacement with energy consumption.

MetricHuayi HYE69Y63 (R134a)Standard 1/5 HP (R600a Equivalent)
Displacement6.9 cm³10.2 cm³
Operating PressurePositive (Standard)Low / Near-Vacuum
Efficiency (COP)1.30 W/W1.50 W/W
Gas Charge WeightModerate (~120g)Low (~50g)

Professional Replacement Cross-Reference

Finding a suitable replacement requires matching the BTU/h capacity and the displacement as closely as possible to maintain the refrigerator’s original duty cycle.

5 Compressor Replacements (R134a – Same Gas):

  1. Embraco: EMT55HLP (High performance, near-identical BTU)
  2. ACC / Cubigel: GL70AA (Robust European alternative)
  3. GMCC: PE75H1C (Slightly higher displacement, very reliable)
  4. Secop (Danfoss): PL50F (Compact design for limited spaces)
  5. Tecumseh: FFI6HAK (Standard American replacement)

5 Compressor Replacements (R600a – Different Gas):
Note: Converting from R134a to R600a requires a complete system flush, oil replacement, and potentially a capillary tube adjustment.

  1. TEE: NTU170MT
  2. Cubigel: HMK12AA
  3. Secop: HTK12AA
  4. Huayi: HYB12MHU
  5. Jiaxipera: NT1114Y

Field Engineering Advice and Notices

  • Vacuum Standards: Because R134a systems use POE oil, they are highly sensitive to moisture. A deep vacuum of at least 500 microns is mandatory. Failure to achieve this will lead to acid formation, which destroys the motor windings over time.
  • Thermal Protection: If the compressor “clicks” off frequently, ensure the condenser coils are clean. Static-cooled compressors like the HYE69Y63 rely on natural convection; dust buildup can cause the internal thermal protector to trip prematurely.
  • Start Components: Always replace the PTC relay and the overload protector when installing a new compressor. A fatigued relay can cause the start winding to stay energized too long, leading to a catastrophic burnout of the new unit.
  • Charging by Weight: For R134a, always charge using a digital scale to the exact weight specified on the refrigerator’s nameplate. Charging by “pressure feel” often leads to overcharging, which increases the stress on the 1/5 HP motor.

Conclusion and Practical Benefits

The Huayi HYE69Y63 is a resilient, mid-range compressor that provides a stable cooling solution for millions of households worldwide. For the engineer, it represents a standard “plug-and-play” solution for a wide variety of refrigeration brands. Its dual-frequency capability and high copper-content windings make it an exceptionally forgiving unit in regions where power grid stability may fluctuate.

Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro
Huayi HYE69Y63 Compressor 1/5 HP R134a LBP mbsmpro

Leave a Reply

Your email address will not be published. Required fields are marked *

Related Posts

Copeland CS16K6E-PFZ-155 Compressor

The Copeland CS16K6E-PFZ-155 is a high-efficiency hermetic reciprocating compressor designed for commercial refrigeration. Operating at 220-240V and 50Hz, this 1.25…

Compressor, LG, BMH089NHMV, 1/4 hp

The LG BMH089NHMV is a 1/4 HP inverter compressor utilizing R600a refrigerant for high-efficiency refrigeration. With a variable speed range…

Maneurop MTZ160HW4VE

Maneurop MTZ160HW4VE 13 hp reciprocating compressor R404A R507A R134a R407C 20.3 kW medium temperature cold room applications

Electrostar 16 foot refrigerator 1/6 HP compressor 125W top freezer Mbsmgroup

Electrostar’s 16‑foot refrigerator remains a practical choice for families who want reliable cooling and manageable energy use. With a capacity…

AC vs DC Refrigerator Compressors

DC inverter refrigerator compressor vs AC compressor energy efficiency, noise level, temperature control, digital inverter technology, home and commercial cooling…

The 5 Pillars of Refrigeration Diagnosis: Professional HVAC

Professional HVAC technicians rely on five critical diagnostic pillars: suction pressure, discharge pressure, superheat, subcooling, and saturation temperature relationships. Mastering…