Technical data, tools and notes for refrigeration and electronics technicians.

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro
3, Feb 2026
Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers
image_pdfimage_print

Focus Keyphrase

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers

SEO Title

Mbsmpro.com, Compressor, ETK130L, 1/4 hp, Donper, Cooling, R600a, 220 W, 1.1 A, 1Ph 220‑240V 50Hz, LBP, RSCR, −35°C to −10°C, Freezing

Meta Description

Technical deep-dive into the Donper ETK130L compressor. Includes 1/4 HP R600a performance charts, cooling capacity, electrical schematics, and expert cross-reference guides.

Slug

donper-etk130l-compressor-r600a-1-4hp-specs-replacement

Excerpt

The Donper ETK130L compressor is a high-efficiency 1/4 HP unit designed for low back pressure applications using R600a refrigerant. This article provides a comprehensive technical breakdown, including cooling capacity, electrical schematics, and cross-reference replacements. Ideal for technicians and engineers seeking precise data for maintenance and system optimization in domestic and light commercial refrigeration.


Donper ETK130L: The Engineering Standard for Modern R600a Refrigeration

In the evolving landscape of domestic cooling, the Donper ETK130L stands as a testament to efficient, low-impact refrigeration. As a seasoned technician who has spent years in the field, I can tell you that transitioning to R600a (Isobutane) systems required a shift in mindset. The ETK130L is a high-performance 1/4 HP hermetic reciprocating compressor that has become a staple in large-capacity domestic freezers and side-by-side refrigerators.

This unit isn’t just about moving gas; it’s about thermodynamic precision. Engineered by the Huangshi Dongbei Electrical Corp, it targets Low Back Pressure (LBP) environments, ensuring that even when the mercury rises outside, the internal temperatures stay locked in the deep-freeze zone.


Comprehensive Technical Data

FeatureSpecification
ModelETK130L
Utilisation (mbp/hbp/lbp)LBP (Low Back Pressure)
Domaine (Freezing/Cooling)Freezing / Deep Cold Storage
Cooling wattage at -23.3°C220 Watts
Cubic feet can this compressor cool?16 to 20 Cubic Feet
Litres can this compressor cool?450 to 550 Liters
Kcal/h189 Kcal/h
Oil Type and quantityMineral / POE – 180ml
Horsepower (HP)1/4 HP
Refrigerant TypeR600a (Isobutane)
Power Supply220-240V / 50Hz / 1Ph
Cooling Capacity BTU750 BTU/h
Motor TypeRSCR (Resistive Start – Capacitive Run)
Displacement13.0 cm³
Winding MaterialHigh-Grade Copper
Pression ChargeLow Pressure (Suction)
Capillary0.031″ / 0.8mm (Approx. 3 meters)
Model Fridge CompatibilityLarge Chest Freezers, Samsung/LG Style Fridges
Temperature function-35°C to -10°C
With fan or noGenerally Static (Forced air optional)
Commercial or noDomestic / Light Commercial
Amperage in function1.1 A
LRA (Locked Rotor Amps)8.2 A
Type of relayPTC (Positive Temperature Coefficient)
Capacitor or no and valeurRun Capacitor: 4µF or 5µF
Country of originChina

Efficiency Metrics & Thermodynamic Performance (COP)

Understanding the Coefficient of Performance (COP) is critical for any engineer looking to optimize energy star ratings. Below is the performance curve for the ETK130L at various evaporating stages.صورة vapor compression refrigeration cycle diagram

Shutterstock

Evaporating Temp (°C)Cooling Capacity (Watts)Power Consumption (Watts)COP (W/W)
-351281181.08
-301651351.22
-23.3 (Standard)2201551.42
-202581681.54
-153151851.70
-103852051.88
0540 (N/A for LBP)
4
10

Electrical Schematic: RSCR Configuration

The ETK130L typically utilizes an RSCR (Resistive Start – Capacitive Run) setup to maximize energy savings. Here is the logical wiring layout:

  1. Common (C): Connects to the Overload Protector (OLP).
  2. Main/Run (R): Connects directly to the Neutral line.
  3. Start (S): Connects through the PTC Relay.
  4. Run Capacitor: Wired across the Start and Run terminals of the PTC relay to maintain current phase alignment during operation, significantly lowering the running amperage.

Field Note: If you find the compressor “clicking” without starting, check the 4µF capacitor. A failed capacitor in an RSCR system often prevents the motor from overcoming its initial torque requirements.


Comparative Analysis: R600a vs. R134a Equivalents

When comparing the ETK130L (R600a) to an older R134a unit like the GP12, several differences emerge:

  • Operating Pressure: The ETK130L operates under a vacuum on the suction side or at very low positive pressure. R134a units run at much higher pressures.
  • Lubrication: R600a is highly miscible with mineral oil, whereas R134a strictly requires synthetic POE/PAG oils.
  • Energy Consumption: The ETK130L generally consumes 10-15% less electricity than its R134a counterpart for the same cooling output.

Cross-Reference Replacement Guide

5 Replacements (Same Gas: R600a)

  1. Secop (Danfoss): NLE13KK.4
  2. Embraco: EMX70CLC
  3. Jiaxipera: NT1114Y
  4. Huayi: HYB130MHU
  5. LG: CMA121LHEG

5 Replacements (Alternative Gas: R134a)

Note: Using these requires a complete system flush and oil change.

  1. Embraco: FFI10HAK (1/3 HP to match R600a displacement)
  2. Secop: TLES10KK.3
  3. ZMC: GL90AA
  4. Donper: GP12TG
  5. Tecumseh: THB1390YS

Engineering Advice & Maintenance Notice

  • Safety: R600a is flammable. Never use a standard piercing valve for long-term service. Brazing should only be performed after ensuring the system is completely purged with Nitrogen.
  • Vacuum Depth: Aim for 200 microns. Moisture is the enemy of the long-term reliability of the internal valves.
  • Charging: Always charge by weight using a digital scale. R600a systems are extremely sensitive; even an overcharge of 5 grams can cause liquid slugging.

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, ETK130L, R600a, NLE13KK, EMX70CLC, NT1114Y, HYB130MHU, CMA121LHEG, FFI10HAK, TLES10KK, GL90AA, GP12TG, THB1390YS, Compressor Replacement, 1/4 HP Compressor, LBP Refrigeration.

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro
Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro

Leave a Reply

Your email address will not be published. Required fields are marked *

Related Posts

How many cubic feet can LJ118CY1 compressor cooling ?

The Donper LJ118CY1 is a high-performance 1/4 HP hermetic compressor designed for domestic refrigerators using R600a refrigerant. Known for its…

TECUMSEH, DAIKIN, MATSUSHITA, HITACHI & TOSHIBA MODELS

Understanding refrigeration compressor specifications is essential for proper HVAC system selection and maintenance. This comprehensive guide covers five major compressor…

Mitsubishi Electric PUHY-P250YKH-TH

The Mitsubishi Electric PUHY-P250YKH-TH stands out as a powerful 25HP outdoor unit in the City Multi VRF series, designed for…

HITACHI FL20S88NAA Compressor

The HITACHI FL20S88NAA 0.75 HP hermetic scroll compressor delivers 256W cooling capacity at 50Hz, utilizing HFC-134a refrigerant for household refrigerator-freezer…