Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP

Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP mbsmpro

Focus Keyphrase: Konor GPY16AF R134a Compressor Technical Specifications and Professional Replacement Guide

SEO Title: Mbsmpro.com, Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP, 220-240V 50Hz, Freezing, Technical Data

Meta Description: Explore the full technical breakdown of the Konor GPY16AF compressor. This 1/2 HP R134a unit is ideal for LBP freezing applications. Includes specs, wiring, and cross-reference.

Slug: konor-gpy16af-compressor-r134a-lbp-specs

Tags: Konor, GPY16AF, R134a, 1/2 HP, LBP, Compressor, Freezing, Refrigeration, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm

Excerpt: The Konor GPY16AF is a robust hermetic reciprocating compressor engineered for low back pressure applications using R134a refrigerant. With a displacement of 16.2 cm³, this 1/2 HP unit is a staple in commercial freezers and large refrigerators. This guide provides detailed technical data, wiring diagrams, and professional cross-reference options for field technicians.


Mbsmpro.com, Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP, 220-240V 50Hz

The refrigeration industry relies on precision and durability, and the Konor GPY series stands out as a high-performance solution for low-temperature requirements. Specifically, the GPY16AF model is a hermetic reciprocating compressor designed to meet the rigorous demands of deep-freezing units. Utilizing R134a refrigerant, this compressor balances thermal efficiency with mechanical reliability, making it a preferred choice for large-capacity domestic appliances and light commercial units.

Technical Specification Table

Feature Specification
Model GPY16AF
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Deep Cold Storage
Oil Type and Quantity POE Oil / 350 ml
Horsepower (HP) 1/2 HP
Refrigerant Type R134a
Power Supply 220-240V / 50Hz / 1 Phase
Cooling Capacity BTU Approximately 1540 BTU/h (at -23.3°C ASHRAE)
Motor Type CSIR (Capacitor Start – Induction Run)
Displacement 16.2 cm³
Winding Material High-Grade Copper
Pressure Charge Suction: 0.5 – 5 PSI (Normal LBP range)
Capillary Recommendation 0.042″ x 10ft (Variable per load)
Application Units Large Chest Freezers, Vertical Freezers
Temperature Function -35°C to -15°C
Fan Requirement Static or Forced Air (Fan recommended for high ambient)
Commercial Use Yes, Light Commercial / Domestic
Amperage (FLA) 2.5 A – 2.8 A
LRA (Locked Rotor Amps) 17 A
Type of Relay Potential or Electromagnetic Relay
Capacitor Requirement Starting Capacitor (approx. 60-80 µF)

Engineering Perspective: Performance Analysis

From a field worker’s perspective, the GPY16AF is recognized for its high volumetric efficiency. The 16.2 cm³ displacement allows for rapid pulldown times in large evaporation systems. Unlike smaller residential compressors, this unit features reinforced copper windings that handle the high torque required during the startup phase of a heavy refrigeration cycle.

When comparing the Konor GPY16AF to other market leaders, we notice a distinct advantage in its thermal management. The internal motor protection is calibrated to prevent burnout during voltage fluctuations, a common issue in many regions.

Cross-Reference and Replacement Models

Finding an exact match for a compressor in the field is not always possible. Below are professional alternatives categorized by refrigerant type.

Table: Top 5 Replacements (Same Refrigerant – R134a)

Brand Model HP Displacement
Embraco FFI12HBX 1/2 HP 11.14 cm³
Danfoss/Secop SC15G 1/2 HP 15.28 cm³
Tecumseh AE2415Y 1/2 HP 12.50 cm³
Kulthorn AE7440Y 1/2 HP 14.50 cm³
Huayi HYE15YG 1/2 HP 15.00 cm³

Table: Top 5 Replacements (Alternative Refrigerant – R404a/R600a)

Brand Model Gas Type Note
Embraco NEK2150GK R404a Requires TXV adjustment
Secop SC18CL R404a High cooling capacity
Jiaxipera VNX1116Y R600a High efficiency / Low noise
Nidec GPY12RAA R600a Eco-friendly alternative
Danfoss NL11MF R134a/R404a Multi-refrigerant capable

Electrical Wiring Schema (General CSIR)

codeText

[Neutral] ---------------- (Common Terminal)
                                      |
                                  [Winding]
                                      |
       [Live] -----[Overload]----[Relay]---- (Main Winding)
                                    |
                                [Start Cap]
                                    |
                                (Start Winding)

Installation Best Practices and Field Tips

  1. Vacuum Procedure: Since the GPY16AF uses POE oil, it is extremely hygroscopic. A deep vacuum of at least 500 microns is mandatory to prevent acid formation within the system.
  2. Filter Drier Replacement: Never reuse a filter drier. When installing this 1/2 HP unit, ensure a high-capacity XH-9 molecular sieve drier is used to handle the R134a molecular structure.
  3. Oil Management: If the system suffered a motor burnout previously, perform a flush. POE oil will trap contaminants more aggressively than mineral oil.
  4. Capillary Sizing: Ensure the capillary tube is not restricted. A 1/2 HP compressor generates significant head pressure; a restricted capillary will lead to premature valve failure.

Professional Benefits of the Konor GPY16AF

  • Energy Efficiency: Optimized for lower power consumption despite high torque.
  • Low Noise Profile: Advanced shell design dampens mechanical vibration.
  • Durability: Built to withstand continuous operation in tropical climates.

Notice: Always verify the starting capacitor value on the specific unit label before replacement. Using an undersized capacitor can lead to starting failures, while an oversized one may overheat the start winding.

Compressor, Konor, GPY16AF, 1/2 HP, R134a, LBP mbsmpro
1/2 HP, Compressor, freezing, GPY16AF, Konor, LBP, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, refrigeration



Copeland ZB50KCE Scroll Compressor 

Copeland ZB50KCE Scroll Compressor  mbsmpro

Copeland ZB50KCE Scroll Compressor Nameplate: How to Read the Label and Choose the Right Polyester Oil

The photo shows the damaged nameplate of a Copeland ZB50KCE scroll compressor, factory‑charged with polyester (POE) oil for medium‑temperature refrigeration. Correctly interpreting this label helps technicians confirm oil, power, voltage and safety limits during service or replacement.

Compressor identification

The model belongs to the Copeland ZB series, used in commercial cold rooms and process cooling for refrigerants such as R404A, R134a and R22 alternatives. Depending on voltage code (TFD‑551, TFD‑950, etc.), it is sold as a 7 hp medium‑temperature compressor with around 11.9 kW nominal capacity.

  • Model code example: ZB50KCE‑TFD‑551 or ZB50KCE‑TFD‑950.
  • Technology: Hermetic scroll, part of the Summit series designed for higher seasonal efficiency.

Polyester oil (POE) on the label

The upper part of the label still shows POLYESTER OIL, confirming that the compressor is charged with POE lubricant. Catalogues list oil charges of about 2.6–2.7 l using approved POE types such as RL32‑3MAF or Mobil EAL Arctic 22 CC, depending on the variant.

  • POE oil absorbs moisture quickly, so systems must be evacuated deeply and fitted with quality filter‑driers.
  • Only compatible POE grades should be added; mixing with mineral or alkylbenzene oil is not permitted.

Technical data with hp and W

The following table compiles typical data for a Copeland ZB50KCE‑TFD‑551 running as a medium‑temperature refrigeration compressor; values may vary slightly by refrigerant and exact model.

Parameter Typical value for ZB50KCE*
Nominal power 7 hp
Nominal capacity 11.9 kW cooling (≈11 900 W)
Electrical power input ≈7.5–7.9 kW depending on conditions
Displacement 19.8 m³/h
Supply voltage 380–420 V/3/50 Hz and 460 V/3/60 Hz (TFD code)
Maximum operating current 14.6 A
Locked‑rotor current ≈100 A
Oil type POE (e.g. RL32‑3MAF)
Oil quantity 2.6–2.7 l
Sound level ≈64 dBA at 1 m
Net weight ≈59 kg (TFD‑551)

*Always confirm with the exact data sheet for your compressor code.

Voltage and operating limits on the sticker

On the lower part of the photographed label, remnants of “Volt 1 380 … Volt 2 460” can be identified, matching the dual‑voltage three‑phase motor used in TFD models. Another line mentions maximum current around 14.6 A, which is the value used to size breakers, contactors and cables.

  • The TFD motor code indicates 380–420 V/3/50 Hz and 460 V/3/60 Hz with internal motor protection.
  • Respecting these limits and using proper overload protection prevents overheating and nuisance trips in commercial installations.

Practical maintenance notes

For technicians such as those in Mbsmgroup and Mbsm.pro, a faded nameplate is common on older units, but the combination of model code and official catalogue restores all critical information. Creating a new service label with hp, kW, voltage, POE oil type and charge simplifies future troubleshooting and reduces the risk of mistakes during oil changes or retrofits.

  • When replacing or topping up oil, always isolate the compressor, recover refrigerant and work under clean, dry conditions.
  • If in doubt about capacity or application limits, refer to the Copeland ZB range catalogue and selection software before approving a replacement.
Copeland ZB50KCE Scroll Compressor  mbsmpro