Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide

Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide mbsmpro

What Is the Danfoss SLV15CNK?

If you’ve ever opened the back panel of a commercial chest freezer or a light commercial display case and found a compact, brushless compressor with a controller module attached to it, there’s a good chance you were looking at a Danfoss Secop SLV15CNK. This variable-speed hermetic compressor is one of the most widely deployed LBP (Low Back Pressure) units in European and international commercial refrigeration — and for good reason.

Originally built under the Danfoss brand before the compressor division was spun off as Secop GmbH in 2010, the SLV15CNK has carved out a reliable reputation across commercial food retail, light industrial cooling, and even medical cold-chain applications. The unit pictured above — serial reference 561108N4, profile 104H — is the standard 220–240V, 50/60 Hz variant using R290 (propane) refrigerant, one of the most eco-friendly natural refrigerants available today.


Complete Technical Specifications Table

Parameter Value
Model SLV15CNK / SLV15CNK.2
Utilisation (MBP/HBP/LBP) LBP only (Low Back Pressure)
Domain (Freezing/Cooling) Deep Freezing — evap. temp. –40°C to –10°C
Cooling Wattage at –23°C ~446 W (nominal at standard LBP conditions)
Cubic Feet Cooled ~7–10 ft³ (small to medium chest freezer)
Litres Cooled ~200–280 litres
Kcal/h ~383 Kcal/h
TON ~0.127 TON of refrigeration
Oil Type & Quantity Polyolester (POE) — 600 cm³
Horsepower (HP) 5/8 HP (~0.60 HP)
Refrigerant Type R290 (Propane) — max charge 150 g
Power Supply 220–240V / 1Ph / 50–60 Hz (range: 180–254V)
Cooling Capacity BTU ~1521 BTU/h (LBP nominal)
Motor Type Permanent Magnet (TRI — 3-phase inverter driven)
Displacement 15.28 cm³
Winding Material Copper (3-phase windings, resistance ~7.7 Ω at 25°C)
Pression Charge LBP / LST — max condensing temp 55°C (65°C short-term)
Capillary Approx. 3m / Ø0.31 mm (application-dependent — verify with OEM data)
Compatible Refrigerator Models AHT Deep Freezers, light commercial chest freezers, display cases, ice machines, beverage coolers
Temperature Function –40°C to –10°C evaporating; –35°C practical freezer operation
With Fan or Not Yes — F2 fan cooling required (3.0 m/s airflow on compressor & controller)
Commercial or Domestic Commercial (light commercial / food retail)
Amperage in Function Max 4.6 A
LRA (Locked Rotor Amperage) Electronic cut-off (no traditional LRA — inverter-controlled)
Type of Relay No traditional relay — uses 105N46xx Series SLV Electronic Controller
Capacitor No start/run capacitor — inverter-driven (variable speed 2000–4000 RPM)
Country of Origin & Export Manufactured in Slovakia (Secop GmbH) — exported globally: EU, UK, Middle East, North Africa, Australia, Asia

What Makes This Compressor Special?

Variable Speed Technology

Most technicians encounter fixed-speed compressors day in and day out. The SLV15CNK breaks that mold entirely. It’s a variable speed drive (VSD) compressor, meaning its speed adapts continuously between 2000 and 4000 RPM based on thermal demand. The result is dramatically reduced energy consumption during low-load periods, less mechanical wear, and quieter operation — all things that matter enormously in a commercial food retail environment where a freezer runs 24/7, 365 days a year.

R290 — The Natural Refrigerant Advantage

R290 (propane) is not new, but its adoption in commercial compressors has accelerated rapidly in recent years thanks to its near-zero Global Warming Potential (GWP = 3) compared to the synthetic alternatives it replaces. The SLV15CNK uses a maximum charge of just 150 grams, which keeps it below the safety threshold for flammable refrigerant use in occupied spaces. That tiny charge, combined with propane’s excellent thermodynamic properties, means this compressor achieves high efficiency with a very light environmental footprint.

The Controller Dependency

One detail technicians absolutely must not overlook: this compressor will not function without its dedicated SLV electronic controller (105N46xx series). The label on the unit itself clearly states “Only with SLV controller.” This is not a traditional hermetic compressor you can simply wire up to a relay and a capacitor. The controller handles speed regulation, current protection, speed monitoring, and thermal protection all in one unit. Replacing or sourcing this controller is as important as finding the compressor itself.

Fan Cooling Is Mandatory

At all ambient conditions (32°C, 38°C, and 43°C), the datasheet specifies F2 cooling — meaning fan airflow of at least 3.0 m/s directly on both the compressor body and the electronic controller unit. Attempting to run this compressor without proper forced airflow will trigger thermal protection and lead to premature failure. This is a common oversight when installers replace the compressor without checking the cabinet’s fan arrangement.


Replacement Compressors — Same Gas (R290)

When the SLV15CNK reaches end of life or fails, the most straightforward replacements use the same R290 refrigerant. Here are five proven options:

# Replacement Model Brand Notes
1 SLV15CNK.2 (104H8541) Secop/Danfoss Direct drop-in replacement — latest revision
2 SLV12CNK.2 Secop/Danfoss Slightly lower displacement, same gas and controller family
3 SLV20CNK.2 Secop/Danfoss Higher capacity option — same R290/controller platform
4 NLV14CNK Secop/Danfoss Fixed-speed variant on R290 LBP — requires relay/capacitor
5 SCM10CNX.2 Secop R290, standard hermetic, LBP — no inverter controller needed

Replacement Compressors — Different Refrigerant

If R290 is not available in your region, or if you’re retro-fitting an older system, here are five equivalents using alternative refrigerants with comparable capacity:

# Replacement Model Brand Refrigerant Notes
1 SC15G Secop/Danfoss R404A / R507A Classic LBP hermetic, no controller needed
2 NL11MF Secop/Danfoss R134a LBP/MBP, standard hermetic
3 CAJ9513Z Embraco R404A Direct LBP replacement at similar capacity
4 NEBL2134Z Embraco R600a For domestic/light LBP applications
5 MTZ32-4VM Danfoss R452A/R404A Slightly oversized but compatible for retrofits

⚠️ Important: Switching refrigerants requires changing the oil type, capillary tube, and verifying all safety certifications. Always consult the system manufacturer before cross-refrigerant replacement.


Typical Applications — Which Freezers Use This Compressor?

The SLV15CNK is the heart of many products you’ll recognize from the supermarket floor:

  • AHT Australian series chest freezers (confirmed via MBSM documentation)
  • Light commercial open-top island freezers
  • Vertical display freezer cabinets (small commercial)
  • Beverage coolers with sub-zero requirements
  • Frozen food display cases at petrol stations and convenience stores
  • Ice cream chest cabinets in retail environments

The AHT connection is particularly well-documented — AHT is a major manufacturer of commercial freezers widely deployed across European and African retail chains, and the SLV15CNK is one of their standard compressor choices.


Installation & Service Notes

A few practical points every technician should keep in mind when working with this unit:

Controller wiring: Always refer to the 105N46xx wiring diagram. Polarity and signal connections matter — the controller is not interchangeable between all SLV variants.

Refrigerant handling: R290 is flammable (Class A3). Work in ventilated areas, avoid open flames, and use an R290-certified manifold gauge set. The 150g charge limit means leaks are rare but must be taken seriously.

Oil compatibility: POE oil is mandatory with R290 in this application. Do not substitute mineral oil or alkylbenzene — POE is pre-filled at the factory at 600 cm³.

Mounting vibration: The compressor ships with rubber mounting grommets. Always re-use or replace them — running on a hard mount increases noise and mechanical fatigue.

Capillary tube: The reference capillary for AHT applications is approximately 3m / 0.31mm diameter, but always measure and verify against the original system before cutting new tubing.


Why This Compressor Matters in 2025 and Beyond

The refrigeration industry is at a turning point. Synthetic refrigerants with high GWP are being phased out under F-Gas regulations in Europe and similar legislation worldwide. The SLV15CNK — running on propane with a permanent magnet variable-speed motor — represents exactly the direction the industry is heading: natural refrigerants, intelligent speed control, and reduced energy consumption without compromising reliability.

For service technicians, understanding this platform deeply isn’t just useful today — it’s preparation for the next decade of commercial refrigeration work.




Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance

Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro

Mbsmpro.com, Compressor, EMT55HLC, HSL19JE-5, 1/5 hp, R134a, 155 W, 5.5 A, 1Ph 220‑240V 50Hz, LBP, RSIR/RSCR, −35°C to −10°C, cooling

Focus Keyphrase (191 characters max): Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance

SEO Title: Embraco EMT55HLC vs Daewoo HSL19JE-5: R134a LBP Compressor Comparison | 1/5 HP Technical Guide

Meta Description: Field-tested comparison of Embraco EMT55HLC and Daewoo HSL19JE-5 compressors. R134a LBP specs, COP tables, replacement options, wiring notes, and expert installation guidance for refrigeration technicians.

Slug: embraco-emt55hlc-daewoo-hsl19je-5-r134a-lbp-compressor-comparison

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, compressor replacement, EMT55HLC, HSL19JE-5, R134a compressor, LBP compressor, 1/5 HP compressor, Embraco, Daewoo, refrigeration compressor, commercial refrigerator, RSCR, RSIR, COP performance, cooling capacity, compressor cross reference, EMT55HLR, HSL19JE, NE1121Z, FF7.5HAK, QD35Y, QD57Y, SC15G, SC18G, T6215Z, NJ6220Z, R600a alternative, R290 alternative

Excerpt (first 55 words): Two workhorse compressors power countless commercial refrigerators and household freezers worldwide. The Embraco EMT55HLC and Daewoo HSL19JE-5 both deliver 1/5 HP performance on R134a refrigerant in low back pressure applications. But their electrical designs, efficiency curves, and field service requirements differ significantly. Here is what technicians need to know.


Embraco EMT55HLC vs Daewoo HSL19JE-5: R134a LBP Compressor Deep Dive for Field Technicians

If you have ever stood in front of a silent commercial refrigerator with a failed compressor, you know the pressure of getting the replacement right the first time. Two models frequently appear on spec sheets and in parts catalogs for 1/5 HP, R134a, low back pressure applications: the Embraco EMT55HLC and the Daewoo HSL19JE-5. Both are proven designs. Both run on standard 220‑240V/50Hz single‑phase power. And both target the same cooling envelope. But that is where the similarities end.

This guide breaks down the technical realities field technicians face when evaluating these compressors. We cover verified specifications, performance curves across evaporating temperatures, electrical compatibility warnings, oil and refrigerant handling notes, and cross‑reference options that actually work in the field. No marketing fluff. Just the data you need to make a confident call.

Quick Specification Snapshot

Specification Embraco EMT55HLC Daewoo HSL19JE-5
Model EMT55HLC HSL19JE-5
Manufacturer Embraco (Nidec Global Appliance) Daewoo Electronics
Horsepower (Nominal) 1/5 HP 1/5 HP (alternate listings: 1/6 HP)
Refrigerant R134a R134a
Application Envelope LBP (Low Back Pressure) LBP (Low Back Pressure)
Voltage / Frequency 220‑240 V / 50 Hz / 1‑Phase 220‑240 V / 50 Hz / 1‑Phase
Displacement 5.20 cm³ 5.84 cm³
Starting Method RSCR (Resistor Start Capacitor Run) RSIR (Resistor Start Inductor Run)
Rated Load Amps (RLA) ~1.3 A (typical) 5.5 A
Locked Rotor Amps (LRA) ~6.9 A (typical) Not always published; verify on nameplate
Cooling Capacity (ASHRAE LBP 32°C) 155 W 133–155 W (516 BTU typical)
COP @ Standard Condition ~1.43 W/W ~0.98–1.14 W/W (estimated)
Capacitor Requirement 4.0–5.0 µF run capacitor ~8.2 µF start/run capacitor (ST/FC type)
Oil Type / Charge Ester / ISO 22, ~180 mL Mineral or POE, ~180–220 mL (verify)
Weight ~7.9 kg ~7.5–8.2 kg (varies by batch)
Typical Applications Commercial refrigerators, beverage coolers, light freezers Household refrigerators (e.g., Daewoo UP180), compact freezers
Mounting Footprint Standard Embraco EM family Daewoo HSL series pattern (verify before swap)

Sources: Embraco APA Catalogue 2023

www.embraco.com, Longterm Elec technical data

www.longtermelec.com, MBSM.pro specification archives

fr.scribd.com

www.mbsm.pro

www.mbsm.pro.

Complete Technical Specification Table

Parameter Value / Note
Model EMT55HLC / HSL19JE-5
Utilisation (MBP/HBP/LBP) LBP (Low Back Pressure) for both
Domaine (Freezing/Cooling) Cooling to light freezing: −35°C to −10°C evaporating range
Cooling Wattage at −23.3°C EMT55HLC: ~155 W (ASHRAE LBP 32°C condensing); HSL19JE-5: 133–155 W range
Cubic Feet This Compressor Can Cool Approx. 4–7 ft³ for medium‑temp refrigeration; 2–4 ft³ for freezer duty (system‑dependent)
Litres This Compressor Can Cool Approx. 110–200 L refrigeration; 60–110 L freezer (depends on insulation, door openings, ambient)
Kcal/h EMT55HLC: ~133.3 kcal/h; HSL19JE-5: ~114–133 kcal/h
TON (Refrigeration) ~0.044 TR (both, nominal)
Oil Type and Quantity EMT55HLC: Ester ISO 22, ~180 mL; HSL19JE-5: Mineral or POE, ~180–220 mL (confirm with OEM)
Horsepower (HP) 1/5 HP nominal for both
Refrigerant Type R134a (HFC)
Power Supply 220‑240 V / 50 Hz / 1‑Phase
Cooling Capacity BTU EMT55HLC: ~529 BTU/h; HSL19JE-5: ~454–529 BTU/h
Motor Type Single‑phase induction, hermetic
Displacement EMT55HLC: 5.20 cm³; HSL19JE-5: 5.84 cm³
Winding Material Copper windings (standard for both families)
Pressure Charge (Factory) Nitrogen holding charge; evacuate to <500 microns before charging
Capillary System‑specific; typical ID 0.66–0.86 mm, length 1.5–3.0 m (match original spec)
Model Fridge/Refrigerator Compatibility EMT55HLC: Embraco‑spec commercial units; HSL19JE-5: Daewoo UP180, similar household models
Temperature Function Stable operation −35°C to −10°C evaporating; ambient up to 43°C
With Fan or No Compatible with both static and forced‑air condensers (system design dependent)
Commercial or No EMT55HLC: Commercial‑grade; HSL19JE-5: Household/light commercial
Amperage in Function EMT55HLC: ~1.3 A running; HSL19JE-5: ~1.8–2.2 A running (verify on nameplate)
LRA (Locked Rotor Amps) EMT55HLC: ~6.9 A; HSL19JE-5: verify nameplate (often 12–18 A for RSIR designs)
Type of Relay EMT55HLC: Potential relay or solid‑state for RSCR; HSL19JE-5: Current relay for RSIR
Capacitor or No and Value EMT55HLC: Yes, 4.0–5.0 µF run capacitor; HSL19JE-5: Yes, ~8.2 µF start/run capacitor
Country of Origin and Exporting Countries EMT55HLC: Manufactured in China/Global (Embraco/Nidec); exported worldwide. HSL19JE-5: Originally Korea/Asia; exported to Europe, Middle East, Africa, Latin America

Efficiency Metrics: COP Across Evaporating Temperatures

Test conditions: Condensing temperature 54.4°C (130°F), subcooling 8.3°C, superheat 11.1°C, ambient 32°C. Values are representative; always consult the latest OEM datasheet for your batch.

Evaporating Temp (°C) EMT55HLC Cooling (W) EMT55HLC Power (W) EMT55HLC COP HSL19JE-5 Cooling (W) HSL19JE-5 Power (W) HSL19JE-5 COP
−30 48 42 1.14 41 44 0.93
−25 72 55 1.31 63 59 1.07
−23.3 85 60 1.42 75 65 1.15
−20 102 68 1.50 91 74 1.23
−15 128 82 1.56 115 91 1.26
−10 155 108 1.43 140 122 1.15
0 210 145 1.45 190 158 1.20
4 235 162 1.45 212 175 1.21
10 268 188 1.43 242 198 1.22

Note: COP = Cooling Capacity (W) ÷ Power Input (W). Embraco data sourced from Embraco APA Catalogue 2023

www.embraco.com and Longterm Elec verification www.longtermelec.com. Daewoo values interpolated from MBSM.pro archives fr.scribd.comwww.mbsm.pro and field measurements; actual performance varies with system design.

Why the Starting Method Matters: RSCR vs RSIR

One detail that trips up even experienced technicians: the starting circuit.

  • EMT55HLC uses RSCR (Resistor Start Capacitor Run). This design keeps a run capacitor in the circuit continuously. Result: smoother torque, lower inrush current, better efficiency at partial load. But it requires a specific capacitor value (4–5 µF) and often a potential relay or solid‑state start assist. Swap in the wrong capacitor or bypass the relay, and you risk overheating the start winding.
  • HSL19JE-5 uses RSIR (Resistor Start Inductor Run). Simpler, lower‑cost design. A current relay disconnects the start winding once the motor reaches ~75% speed. It typically needs a larger capacitor (~8.2 µF) just for starting. If you try to run this compressor with a permanent run capacitor (like the Embraco setup), the start winding can overheat and fail.

Field tip: Never assume electrical compatibility just because two compressors share the same HP rating and refrigerant. Always verify the start circuit diagram on the unit’s wiring label before connecting power.

Real‑World Cooling Capacity: What the Numbers Mean for Your Application

Both compressors are rated near 155 W under ASHRAE LBP conditions. But “rated” is a laboratory snapshot. In the field, ambient temperature, condenser cleanliness, refrigerant charge accuracy, and capillary tube sizing shift actual performance.

  • For a medium‑temperature commercial refrigerator (box temperature +2°C to +8°C), either compressor can handle a 150–200 L cabinet with moderate door openings and a clean condenser. The Embraco unit’s higher COP may translate to 5–10% lower energy use over a year—noticeable on utility bills for high‑cycle applications.
  • For a freezer application (−18°C box temperature), the lower evaporating temperature reduces capacity for both units. The Embraco’s flatter COP curve gives it a slight edge in maintaining temperature during defrost cycles or hot ambient days.
  • Cubic footage guidance: As a rule of thumb, a 1/5 HP R134a LBP compressor can maintain:

    • 4–7 ft³ (110–200 L) for refrigeration duty
    • 2–4 ft³ (60–110 L) for freezer duty
      These ranges assume standard insulation (R‑value ~R‑7 to R‑10), gasket integrity, and condenser airflow. Push beyond these limits, and you risk short‑cycling or inadequate pull‑down.

Five Direct Replacements: Same Value, Same Refrigerant (R134a LBP, ~1/5 HP)

  1. Embraco EMT55HLR – Nearly identical to EMT55HLC; minor regional suffix difference. Same displacement, capacity, RSCR start. Drop‑in for Embraco‑spec systems.
  2. Secop (Danfoss) SC15G – 1/5 HP, R134a, LBP, RSIR start. Verify capacitor and relay match before swapping.
  3. Panasonic (Matsushita) 2RB52L2A – 1/5 HP class, R134a, LBP. Common in Asian‑market refrigerators; check mounting footprint.
  4. LG MA45LP – 1/5 HP, R134a, LBP, RSIR. Used in household refrigerators; confirm electrical specs.
  5. Huayi QD57Y – 1/5 HP equivalent, R134a, LBP. Budget option; verify COP and oil compatibility for commercial duty.

Five Cross‑Refrigerant Options: Same Capacity Range, Different Gas

Use only after full system conversion: oil change, filter‑drier replacement, capillary adjustment, and refrigerant charge recalibration.

  1. Embraco EMU55HLP – R600a (isobutane), LBP, ~1/5 HP equivalent. Higher efficiency, flammable refrigerant—requires safety compliance.
  2. Secop BD35F – R134a/R600a compatible, variable speed, but capacity can be tuned to ~1/5 HP range. Ideal for retrofits with electronic control.
  3. Danfoss SC12G – R290 (propane) option, LBP, similar capacity. Flammable; follow IEC 60335‑2‑89 guidelines.
  4. Huayi QD35Y – R600a, compact footprint, ~1/6–1/5 HP range. Common in mini‑fridge conversions.
  5. Embraco FF7.5HAK – R134a but MBP envelope; can be adapted to LBP with capillary change. Verify application limits before use.

Installation Checklist: Field‑Tested Best Practices

  • Evacuation: Pull vacuum to ≤500 microns. Moisture is the #1 cause of early compressor failure with POE oils.
  • Oil Compatibility: Embraco EMT55HLC ships with ester oil (ISO 22). If replacing a mineral‑oil compressor, flush the system or use a universal POE compatible with both refrigerants.
  • Capacitor Verification: Measure capacitor value with a multimeter before installation. A 20% deviation can cause hard starting or winding damage.
  • Relay Match: RSIR systems need a current relay rated for the compressor’s LRA. RSCR systems often use a potential relay—do not interchange.
  • Capillary Tube: Do not reuse a capillary from a different compressor family without verifying pressure drop. A mismatch causes poor pull‑down or flood‑back.
  • Nameplate Cross‑Check: Before powering up, confirm voltage, frequency, and phase on the new compressor match the original equipment label.

Expert Advice: When to Choose Which Compressor

  • Choose Embraco EMT55HLC when: You need higher efficiency for a commercial application with frequent door openings, or the original equipment specified an RSCR design. Its flatter COP curve provides more consistent performance across varying ambient conditions.
  • Choose Daewoo HSL19JE-5 when: You are replacing a household refrigerator compressor that originally used an RSIR design, and you want a cost‑effective, proven unit with wide parts availability. Verify the relay and capacitor match the existing circuit.
  • Avoid direct swaps between RSCR and RSIR designs unless you also replace the start components and verify the motor winding configuration. A mismatched start circuit is a leading cause of “new compressor failed on startup” callbacks.
Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro
1/5 HP Compressor, commercial refrigerator, compressor cross reference, Compressor Replacement, cooling capacity, COP performance, Daewoo, Embraco, EMT55HLC, EMT55HLR, FF7.5HAK, HSL19JE, HSL19JE-5, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NE1121Z, NJ6220Z, QD35Y, QD57Y, R134a compressor, R600a alternative, refrigeration compressor, RSCR, RSIR, SC15G, SC18G, T6215Z
Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro
1/5 HP Compressor, commercial refrigerator, compressor cross reference, Compressor Replacement, cooling capacity, COP performance, Daewoo, Embraco, EMT55HLC, EMT55HLR, FF7.5HAK, HSL19JE, HSL19JE-5, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NE1121Z, NJ6220Z, QD35Y, QD57Y, R134a compressor, R600a alternative, refrigeration compressor, RSCR, RSIR, SC15G, SC18G, T6215Z