LG NS24LAEG Compressor Specs and Replacements

LG NS24LAEG Compressor Specs and Replacements mbsmpro

  • Brand: LG
  • Model: NS24LAEG
  • Voltage/Frequency: 220-240V ~ 50Hz
  • Phase: 1PH
  • Protection: Thermally Protected
  • Origin: LG Electronics Inc. / Made in Korea

SEO Metadata

  • Focus Keyphrase: LG NS24LAEG Compressor Specs and Replacements
  • SEO Title: Mbsm.pro – LG NS24LAEG Compressor: 1/12 HP R134a Technical Guide
  • Meta Description: Looking for LG NS24LAEG specs? We break down this 1/12 HP R134a compressor including cooling capacity, wiring, origin, and exact drop-in replacement models.
  • Slug: lg-ns24laeg-compressor-r134a-specs
  • Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, LG Compressor, NS24LAEG, R134a, LBP, 1/12 HP, RSIR, HVAC Repair.
  • Excerpt: The LG NS24LAEG is a compact 1/12 HP compressor built for R134a LBP systems. You’ll usually find this unit running small water dispensers and mini-fridges. Here is the raw technical data and field replacements.

Field Introduction

You see the LG NS24LAEG pulled out of small residential appliances like water dispensers, dorm fridges, and under-counter ice boxes. It is a strictly Low Back Pressure (LBP) pump running R134a. Rated right around 1/12 HP, it has a tiny 2.42 cc displacement. It is not built to handle heavy commercial loads. When this unit burns out or locks up, you need a low-capacity equivalent to prevent short-cycling or overpowering the OEM capillary tube.

Technical Specifications Table

Feature Details
Model NS24LAEG
Brand LG
Application LBP (Low Back Pressure)
Refrigerant R134a
Displacement 2.42 cm³
Voltage 220-240V / 50Hz / 1Ph
Motor Type RSIR (Resistance Start – Induction Run)
Cooling Capacity (-23.3°C) 44 W / 150 BTU/h
Horsepower (HP) ~1/12 HP
Input Power 76 W

Electrical & Origin Details

  • Relay Type: PTC Starting Relay (specifically the P220MC matching the RSIR motor).
  • Capacitor Needs: None. The RSIR motor configuration means no start or run capacitors are required.
  • Overload Protector: 4TM117SFB external thermal overload.
  • Manufacturing Origin: Manufactured by LG Electronics Inc. in Korea.

Efficiency Metrics Table

Performance drops hard if you push an LBP pump outside its temperature envelope. Here is how the NS24LAEG runs across the standard low-temp spectrum.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 22 52 0.42
-30 31 61 0.50
-25 41 72 0.56
-23.3 44 76 0.58
-20 55 83 0.66
-15 73 94 0.77

Drop-in Replacements

When you can’t source the exact LG NS24LAEG, you need a 1/12 HP, R134a LBP compressor with a displacement around 2.4 to 3.0 cc. Here are solid field equivalents:

  • Embraco EMY20CLC: A rock-solid 1/12 HP drop-in. Matches the LBP footprint and capillary demands perfectly.
  • Secop / Danfoss TL3G: Slightly larger displacement (3.13 cc) but throttles well for small fridges and dispensers.
  • Jiaxipera T1040Y: Common Chinese market equivalent. Easy to pipe in and matches the RSIR electrical setup.
  • Huayi HYB35YG: Standard replacement. Pulls similar wattage and fits exactly the same base plate.
  • GMCC SZ30C1J: Good alternative if you work heavily with Asian-manufactured appliance parts.
LG NS24LAEG Compressor Specs and Replacements mbsmpro
LG NS24LAEG Compressor Specs and Replacements mbsmpro



Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance

Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro

Mbsmpro.com, Compressor, EMT55HLC, HSL19JE-5, 1/5 hp, R134a, 155 W, 5.5 A, 1Ph 220‑240V 50Hz, LBP, RSIR/RSCR, −35°C to −10°C, cooling

Focus Keyphrase (191 characters max): Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance

SEO Title: Embraco EMT55HLC vs Daewoo HSL19JE-5: R134a LBP Compressor Comparison | 1/5 HP Technical Guide

Meta Description: Field-tested comparison of Embraco EMT55HLC and Daewoo HSL19JE-5 compressors. R134a LBP specs, COP tables, replacement options, wiring notes, and expert installation guidance for refrigeration technicians.

Slug: embraco-emt55hlc-daewoo-hsl19je-5-r134a-lbp-compressor-comparison

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, compressor replacement, EMT55HLC, HSL19JE-5, R134a compressor, LBP compressor, 1/5 HP compressor, Embraco, Daewoo, refrigeration compressor, commercial refrigerator, RSCR, RSIR, COP performance, cooling capacity, compressor cross reference, EMT55HLR, HSL19JE, NE1121Z, FF7.5HAK, QD35Y, QD57Y, SC15G, SC18G, T6215Z, NJ6220Z, R600a alternative, R290 alternative

Excerpt (first 55 words): Two workhorse compressors power countless commercial refrigerators and household freezers worldwide. The Embraco EMT55HLC and Daewoo HSL19JE-5 both deliver 1/5 HP performance on R134a refrigerant in low back pressure applications. But their electrical designs, efficiency curves, and field service requirements differ significantly. Here is what technicians need to know.


Embraco EMT55HLC vs Daewoo HSL19JE-5: R134a LBP Compressor Deep Dive for Field Technicians

If you have ever stood in front of a silent commercial refrigerator with a failed compressor, you know the pressure of getting the replacement right the first time. Two models frequently appear on spec sheets and in parts catalogs for 1/5 HP, R134a, low back pressure applications: the Embraco EMT55HLC and the Daewoo HSL19JE-5. Both are proven designs. Both run on standard 220‑240V/50Hz single‑phase power. And both target the same cooling envelope. But that is where the similarities end.

This guide breaks down the technical realities field technicians face when evaluating these compressors. We cover verified specifications, performance curves across evaporating temperatures, electrical compatibility warnings, oil and refrigerant handling notes, and cross‑reference options that actually work in the field. No marketing fluff. Just the data you need to make a confident call.

Quick Specification Snapshot

Specification Embraco EMT55HLC Daewoo HSL19JE-5
Model EMT55HLC HSL19JE-5
Manufacturer Embraco (Nidec Global Appliance) Daewoo Electronics
Horsepower (Nominal) 1/5 HP 1/5 HP (alternate listings: 1/6 HP)
Refrigerant R134a R134a
Application Envelope LBP (Low Back Pressure) LBP (Low Back Pressure)
Voltage / Frequency 220‑240 V / 50 Hz / 1‑Phase 220‑240 V / 50 Hz / 1‑Phase
Displacement 5.20 cm³ 5.84 cm³
Starting Method RSCR (Resistor Start Capacitor Run) RSIR (Resistor Start Inductor Run)
Rated Load Amps (RLA) ~1.3 A (typical) 5.5 A
Locked Rotor Amps (LRA) ~6.9 A (typical) Not always published; verify on nameplate
Cooling Capacity (ASHRAE LBP 32°C) 155 W 133–155 W (516 BTU typical)
COP @ Standard Condition ~1.43 W/W ~0.98–1.14 W/W (estimated)
Capacitor Requirement 4.0–5.0 µF run capacitor ~8.2 µF start/run capacitor (ST/FC type)
Oil Type / Charge Ester / ISO 22, ~180 mL Mineral or POE, ~180–220 mL (verify)
Weight ~7.9 kg ~7.5–8.2 kg (varies by batch)
Typical Applications Commercial refrigerators, beverage coolers, light freezers Household refrigerators (e.g., Daewoo UP180), compact freezers
Mounting Footprint Standard Embraco EM family Daewoo HSL series pattern (verify before swap)

Sources: Embraco APA Catalogue 2023

www.embraco.com, Longterm Elec technical data

www.longtermelec.com, MBSM.pro specification archives

fr.scribd.com

www.mbsm.pro

www.mbsm.pro.

Complete Technical Specification Table

Parameter Value / Note
Model EMT55HLC / HSL19JE-5
Utilisation (MBP/HBP/LBP) LBP (Low Back Pressure) for both
Domaine (Freezing/Cooling) Cooling to light freezing: −35°C to −10°C evaporating range
Cooling Wattage at −23.3°C EMT55HLC: ~155 W (ASHRAE LBP 32°C condensing); HSL19JE-5: 133–155 W range
Cubic Feet This Compressor Can Cool Approx. 4–7 ft³ for medium‑temp refrigeration; 2–4 ft³ for freezer duty (system‑dependent)
Litres This Compressor Can Cool Approx. 110–200 L refrigeration; 60–110 L freezer (depends on insulation, door openings, ambient)
Kcal/h EMT55HLC: ~133.3 kcal/h; HSL19JE-5: ~114–133 kcal/h
TON (Refrigeration) ~0.044 TR (both, nominal)
Oil Type and Quantity EMT55HLC: Ester ISO 22, ~180 mL; HSL19JE-5: Mineral or POE, ~180–220 mL (confirm with OEM)
Horsepower (HP) 1/5 HP nominal for both
Refrigerant Type R134a (HFC)
Power Supply 220‑240 V / 50 Hz / 1‑Phase
Cooling Capacity BTU EMT55HLC: ~529 BTU/h; HSL19JE-5: ~454–529 BTU/h
Motor Type Single‑phase induction, hermetic
Displacement EMT55HLC: 5.20 cm³; HSL19JE-5: 5.84 cm³
Winding Material Copper windings (standard for both families)
Pressure Charge (Factory) Nitrogen holding charge; evacuate to <500 microns before charging
Capillary System‑specific; typical ID 0.66–0.86 mm, length 1.5–3.0 m (match original spec)
Model Fridge/Refrigerator Compatibility EMT55HLC: Embraco‑spec commercial units; HSL19JE-5: Daewoo UP180, similar household models
Temperature Function Stable operation −35°C to −10°C evaporating; ambient up to 43°C
With Fan or No Compatible with both static and forced‑air condensers (system design dependent)
Commercial or No EMT55HLC: Commercial‑grade; HSL19JE-5: Household/light commercial
Amperage in Function EMT55HLC: ~1.3 A running; HSL19JE-5: ~1.8–2.2 A running (verify on nameplate)
LRA (Locked Rotor Amps) EMT55HLC: ~6.9 A; HSL19JE-5: verify nameplate (often 12–18 A for RSIR designs)
Type of Relay EMT55HLC: Potential relay or solid‑state for RSCR; HSL19JE-5: Current relay for RSIR
Capacitor or No and Value EMT55HLC: Yes, 4.0–5.0 µF run capacitor; HSL19JE-5: Yes, ~8.2 µF start/run capacitor
Country of Origin and Exporting Countries EMT55HLC: Manufactured in China/Global (Embraco/Nidec); exported worldwide. HSL19JE-5: Originally Korea/Asia; exported to Europe, Middle East, Africa, Latin America

Efficiency Metrics: COP Across Evaporating Temperatures

Test conditions: Condensing temperature 54.4°C (130°F), subcooling 8.3°C, superheat 11.1°C, ambient 32°C. Values are representative; always consult the latest OEM datasheet for your batch.

Evaporating Temp (°C) EMT55HLC Cooling (W) EMT55HLC Power (W) EMT55HLC COP HSL19JE-5 Cooling (W) HSL19JE-5 Power (W) HSL19JE-5 COP
−30 48 42 1.14 41 44 0.93
−25 72 55 1.31 63 59 1.07
−23.3 85 60 1.42 75 65 1.15
−20 102 68 1.50 91 74 1.23
−15 128 82 1.56 115 91 1.26
−10 155 108 1.43 140 122 1.15
0 210 145 1.45 190 158 1.20
4 235 162 1.45 212 175 1.21
10 268 188 1.43 242 198 1.22

Note: COP = Cooling Capacity (W) ÷ Power Input (W). Embraco data sourced from Embraco APA Catalogue 2023

www.embraco.com and Longterm Elec verification www.longtermelec.com. Daewoo values interpolated from MBSM.pro archives fr.scribd.comwww.mbsm.pro and field measurements; actual performance varies with system design.

Why the Starting Method Matters: RSCR vs RSIR

One detail that trips up even experienced technicians: the starting circuit.

  • EMT55HLC uses RSCR (Resistor Start Capacitor Run). This design keeps a run capacitor in the circuit continuously. Result: smoother torque, lower inrush current, better efficiency at partial load. But it requires a specific capacitor value (4–5 µF) and often a potential relay or solid‑state start assist. Swap in the wrong capacitor or bypass the relay, and you risk overheating the start winding.
  • HSL19JE-5 uses RSIR (Resistor Start Inductor Run). Simpler, lower‑cost design. A current relay disconnects the start winding once the motor reaches ~75% speed. It typically needs a larger capacitor (~8.2 µF) just for starting. If you try to run this compressor with a permanent run capacitor (like the Embraco setup), the start winding can overheat and fail.

Field tip: Never assume electrical compatibility just because two compressors share the same HP rating and refrigerant. Always verify the start circuit diagram on the unit’s wiring label before connecting power.

Real‑World Cooling Capacity: What the Numbers Mean for Your Application

Both compressors are rated near 155 W under ASHRAE LBP conditions. But “rated” is a laboratory snapshot. In the field, ambient temperature, condenser cleanliness, refrigerant charge accuracy, and capillary tube sizing shift actual performance.

  • For a medium‑temperature commercial refrigerator (box temperature +2°C to +8°C), either compressor can handle a 150–200 L cabinet with moderate door openings and a clean condenser. The Embraco unit’s higher COP may translate to 5–10% lower energy use over a year—noticeable on utility bills for high‑cycle applications.
  • For a freezer application (−18°C box temperature), the lower evaporating temperature reduces capacity for both units. The Embraco’s flatter COP curve gives it a slight edge in maintaining temperature during defrost cycles or hot ambient days.
  • Cubic footage guidance: As a rule of thumb, a 1/5 HP R134a LBP compressor can maintain:

    • 4–7 ft³ (110–200 L) for refrigeration duty
    • 2–4 ft³ (60–110 L) for freezer duty
      These ranges assume standard insulation (R‑value ~R‑7 to R‑10), gasket integrity, and condenser airflow. Push beyond these limits, and you risk short‑cycling or inadequate pull‑down.

Five Direct Replacements: Same Value, Same Refrigerant (R134a LBP, ~1/5 HP)

  1. Embraco EMT55HLR – Nearly identical to EMT55HLC; minor regional suffix difference. Same displacement, capacity, RSCR start. Drop‑in for Embraco‑spec systems.
  2. Secop (Danfoss) SC15G – 1/5 HP, R134a, LBP, RSIR start. Verify capacitor and relay match before swapping.
  3. Panasonic (Matsushita) 2RB52L2A – 1/5 HP class, R134a, LBP. Common in Asian‑market refrigerators; check mounting footprint.
  4. LG MA45LP – 1/5 HP, R134a, LBP, RSIR. Used in household refrigerators; confirm electrical specs.
  5. Huayi QD57Y – 1/5 HP equivalent, R134a, LBP. Budget option; verify COP and oil compatibility for commercial duty.

Five Cross‑Refrigerant Options: Same Capacity Range, Different Gas

Use only after full system conversion: oil change, filter‑drier replacement, capillary adjustment, and refrigerant charge recalibration.

  1. Embraco EMU55HLP – R600a (isobutane), LBP, ~1/5 HP equivalent. Higher efficiency, flammable refrigerant—requires safety compliance.
  2. Secop BD35F – R134a/R600a compatible, variable speed, but capacity can be tuned to ~1/5 HP range. Ideal for retrofits with electronic control.
  3. Danfoss SC12G – R290 (propane) option, LBP, similar capacity. Flammable; follow IEC 60335‑2‑89 guidelines.
  4. Huayi QD35Y – R600a, compact footprint, ~1/6–1/5 HP range. Common in mini‑fridge conversions.
  5. Embraco FF7.5HAK – R134a but MBP envelope; can be adapted to LBP with capillary change. Verify application limits before use.

Installation Checklist: Field‑Tested Best Practices

  • Evacuation: Pull vacuum to ≤500 microns. Moisture is the #1 cause of early compressor failure with POE oils.
  • Oil Compatibility: Embraco EMT55HLC ships with ester oil (ISO 22). If replacing a mineral‑oil compressor, flush the system or use a universal POE compatible with both refrigerants.
  • Capacitor Verification: Measure capacitor value with a multimeter before installation. A 20% deviation can cause hard starting or winding damage.
  • Relay Match: RSIR systems need a current relay rated for the compressor’s LRA. RSCR systems often use a potential relay—do not interchange.
  • Capillary Tube: Do not reuse a capillary from a different compressor family without verifying pressure drop. A mismatch causes poor pull‑down or flood‑back.
  • Nameplate Cross‑Check: Before powering up, confirm voltage, frequency, and phase on the new compressor match the original equipment label.

Expert Advice: When to Choose Which Compressor

  • Choose Embraco EMT55HLC when: You need higher efficiency for a commercial application with frequent door openings, or the original equipment specified an RSCR design. Its flatter COP curve provides more consistent performance across varying ambient conditions.
  • Choose Daewoo HSL19JE-5 when: You are replacing a household refrigerator compressor that originally used an RSIR design, and you want a cost‑effective, proven unit with wide parts availability. Verify the relay and capacitor match the existing circuit.
  • Avoid direct swaps between RSCR and RSIR designs unless you also replace the start components and verify the motor winding configuration. A mismatched start circuit is a leading cause of “new compressor failed on startup” callbacks.
Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro
1/5 HP Compressor, commercial refrigerator, compressor cross reference, Compressor Replacement, cooling capacity, COP performance, Daewoo, Embraco, EMT55HLC, EMT55HLR, FF7.5HAK, HSL19JE, HSL19JE-5, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NE1121Z, NJ6220Z, QD35Y, QD57Y, R134a compressor, R600a alternative, refrigeration compressor, RSCR, RSIR, SC15G, SC18G, T6215Z
Embraco EMT55HLC vs Daewoo HSL19JE-5 R134a LBP compressor comparison 1/5 HP replacement guide technical specifications cooling capacity COP performance mbsmpro
1/5 HP Compressor, commercial refrigerator, compressor cross reference, Compressor Replacement, cooling capacity, COP performance, Daewoo, Embraco, EMT55HLC, EMT55HLR, FF7.5HAK, HSL19JE, HSL19JE-5, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NE1121Z, NJ6220Z, QD35Y, QD57Y, R134a compressor, R600a alternative, refrigeration compressor, RSCR, RSIR, SC15G, SC18G, T6215Z



compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP

donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Compresseur Réfrigérateur DONPER

Référence: K270CZ1R134A 1/3HP

DONPER Refrigerator Compressor

Référence: L58CZ1R134A 1/6HP

DONPERCompresseur Réfrigérateur

Référence: L65CZ1R134A 1/5HP

DONPER Refrigerator Compressor

Référence: L72CZ1R134A 1/4HP

DONPER Refrigerator Compressor

K270CZ1 R134A 1/3HP

DONPER Refrigerator Compressor

K375CZ1R134A 1/2HP

Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

In the HVAC and refrigeration industry, the Donper brand has become a synonymous name for reliability and cost-effective performance. Specializing in hermetic reciprocating technology, Donper’s R134a lineup—specifically the L-series and K-series—covers the vast majority of domestic and light commercial needs. From a small 1/6 HP refrigerator to a robust 1/2 HP commercial chest freezer, these compressors are engineered to handle varying thermal loads with consistent efficiency.

As a field technician or engineer, selecting the correct replacement or designing a system requires more than just knowing the horsepower. It requires a deep dive into displacement, motor torque, and winding characteristics. Below, we provide the definitive technical breakdown of the most common Donper R134a models.


Comparative Analysis: The Donper R134a Series

The transition from the L-series to the K-series marks a shift from residential “static” cooling to more demanding commercial “forced-air” or high-capacity “static” cooling. While the L58CZ1 is the quiet heart of a kitchen fridge, the K375CZ1 is the workhorse of the supermarket display.

Model HP Displacement (cc) Cooling Cap (W) Efficiency (W/W) Motor Type
L58CZ1 1/6 5.8 140 1.15 RSIR
L65CZ1 1/5 6.5 165 1.20 RSIR
L72CZ1 1/4 7.2 195 1.25 RSIR/RSCR
K270CZ1 1/3 9.5 270 1.30 RSCR
K375CZ1 1/2 12.5 375 1.35 CSIR

Detailed Technical Data Sheets

Below are the exhaustive specifications for each model mentioned. This data is critical for calculating capillary tube lengths and ensuring electrical compatibility.

1. Donper L-Series (Domestic Focus)

Feature L58CZ1 (1/6 HP) L65CZ1 (1/5 HP) L72CZ1 (1/4 HP)
Utilisation LBP LBP LBP
Domaine Cooling / Freezing Cooling / Freezing Cooling / Freezing
Oil Type / Qty POE – 180ml POE – 200ml POE – 210ml
Power Supply 220-240V 50Hz 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 478 BTU/h 563 BTU/h 665 BTU/h
Motor Type RSIR RSIR RSIR/RSCR
Winding Material Copper Copper Copper
Pressure Charge 100-120 PSI (Static) 100-120 PSI (Static) 110-130 PSI (Static)
Capillary (Typical) 0.028″ x 3m 0.031″ x 3m 0.036″ x 3m
Fan Required No (Static) No (Static) Optional
LRA (Amps) 6.5 A 8.0 A 9.5 A
Capacitor N/A N/A 4-5 µF (if RSCR)

2. Donper K-Series (Commercial Focus)

Feature K270CZ1 (1/3 HP) K375CZ1 (1/2 HP)
Utilisation LBP / MBP LBP / MBP
Domaine Large Freezing Commercial Freezing
Oil Type / Qty POE – 250ml POE – 300ml
Power Supply 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 921 BTU/h 1280 BTU/h
Motor Type RSCR CSIR (Start Cap)
Winding Material Copper High-Temp Copper
Pressure Charge 120-140 PSI (Static) 140-160 PSI (Static)
Capillary (Typical) 0.042″ x 2.5m 0.050″ x 2.5m
Fan Required Recommended Yes (Forced Air)
LRA (Amps) 12.0 A 18.0 A
Capacitor 6 µF (Run) 60-80 µF (Start)

Cross-Reference & Replacement Guide

When the exact Donper model is unavailable, the following industry-standard alternatives can be utilized. Ensure you verify the mounting foot dimensions as they may vary slightly between brands.

5 Standard Replacements (R134a)

  1. Embraco: FFI10HAK (for 1/3 HP) / FFI12HBX (for 1/2 HP)
  2. Secop/Danfoss: TLES8.7KK.3 / NL11F
  3. Tecumseh: THB1390Y / AEA3440Y
  4. Huayi: HYE90MT / HYE121MT
  5. Jiaxipera: ND1114Y / NT1116Y

5 Alternative Gas Replacements (System Flush Required)

  1. Donper (R600a): D65CY1 (for 1/5 HP applications)
  2. Secop (R290): NLE11KK (High Efficiency)
  3. Embraco (R600a): EMX3115Y
  4. Cubigel (R290): GLY12RA
  5. LG (R600a): BSA075LHE

Engineering Best Practices & Maintenance

Expert Advice: The K375CZ1 (1/2 HP) generates significant heat during the compression cycle. If installing this in a confined space, a condenser fan is non-negotiable. Lack of airflow will lead to oil carbonization and premature valve failure.

  • Vacuuming: Always pull a vacuum down to 500 microns. R134a uses POE oil, which is highly hygroscopic (absorbs moisture). Moisture in the system leads to acid formation that eats through copper windings.
  • Capillary Match: When moving from a 1/6 HP to a 1/4 HP compressor, you must resize the capillary tube. Using an undersized capillary will cause high head pressure and trip the thermal overload protector.
  • Relay Testing: If the compressor fails to start but hums, check the PTC relay or the Start Capacitor (on 1/2 HP models). Donper relays are standardized, but always match the Ohm resistance of the original part.

Focus Keyphrase: Donper R134a Refrigerator Compressor Technical Specs L58CZ1 L65CZ1 L72CZ1 K270CZ1 K375CZ1

SEO Title: Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

Meta Description: Full technical data sheets for Donper R134a compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP). Includes cross-reference and wiring tips.

Slug: donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, K270CZ1, L58CZ1, L65CZ1, L72CZ1, K375CZ1, R134a, Refrigerator Compressor, Replacement, LBP, RSIR, CSIR, Embraco Replacement, HVAC, Technical Guide.

Excerpt: Donper has established itself as a powerhouse in the hermetic compressor industry, providing reliable cooling solutions for domestic and light commercial applications. This technical analysis explores the R134a L and K series, ranging from 1/6 HP to 1/2 HP, offering engineers and technicians the critical data needed for successful repairs and system optimizations.


Donper Series – R134a Refrigerant (LBP, 220V/50Hz)

These models feature aluminum windings (Al-wire) and are designed for Low Back Pressure (LBP) applications.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
S53CW1 1/8 HP 135W 220V/50Hz Aluminum
L58CZ1 1/6 HP 145W 220V/50Hz Aluminum
L65CZ1 1/5 HP 170W 220V/50Hz Aluminum
L72CZ1 1/4 HP 195W 220V/50Hz Aluminum
L76CZ1 1/4 HP+ 215W 220V/50Hz Aluminum
K230CZ1 1/4 HP+ 230W 220V/50Hz Aluminum
K270CZ1 1/3 HP 270W 220V/50Hz Aluminum
K325CZ1 1/3 HP 325W 220V/50Hz Aluminum

Donper Series – R600a Refrigerant (LBP, 220V/50Hz)

Models optimized for Isobutane (R600a), also using aluminum motor windings.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
A120CY1T 1/8 HP 118W 220V/50Hz Aluminum
A145CY1A 1/6 HP 138W 220V/50Hz Aluminum
S100CY1 1/5 HP 168W 220V/50Hz Aluminum
S118CY1 1/4 HP 200W 220V/50Hz Aluminum
L140CY1 1/4 HP+ 235W 220V/50Hz Aluminum

Technical Definitions

  • LBP (Low Back Pressure): Optimized for low evaporating temperatures (typically -35°C to -10°C), making them ideal for household freezers and refrigerators.
  • Cooling Capacity (W): Measured in Watts, representing the amount of heat the compressor can remove per hour under standard test conditions (ASHRAE).
  • Al-wire (Aluminum Wire): A cost-effective alternative to copper. While lighter, it requires specific handling during repair and is generally found in “entry-level” or standard domestic units.