spera J7238GE Compressor 1.5 HP R407C HBP Technical Specifications and Performance Data

spera J7238GE Compressor 1.5 HP R407C HBP Technical Specifications and Performance Data mbsmpro

Mbsmpro.com, Compressor, Aspera, J7238GE, 1.5 HP, Embraco, Cooling, R407C, 3800 W, 7.5 A, 1Ph 220-240V 50Hz, HBP, CSR, 0°C to +15°C, Commercial Cooling


Technical Specifications: Aspera J7238GE

Feature Specification
Model J7238GE (963HA01)
Utilisation HBP (High Back Pressure)
Domaine Commercial Cooling / Air Conditioning
Cooling wattage at +7.2°C 3,845 W
Cubic feet can this compressor cool? Approx. 180 – 250 cu. ft (Application dependent)
Litres can this compressor cool? Approx. 5,000 – 7,000 Liters
Kcal/h 3,306 Kcal/h
TON (Refrigeration) 1.1 Ton
Oil Type and Quantity POE 22 (Polyolester) / 887 ml
Horsepower (HP) 1.5 HP
Refrigerant Type R407C
Power Supply 220-240V / 50Hz / 1 Phase
Cooling Capacity BTU 13,119 BTU/h
Motor Type CSR (Capacitor Start – Run)
Displacement 32.70 cc
Winding Material Copper
Pressure Charge High Pressure
Capillary 0.070″ to 0.080″ (Length varies by design)
Refrigerator/Unit Compatibility Large walk-in coolers, industrial water chillers
Temperature Function -5°C to +15°C (Evaporating Range)
With Fan or No Fan Required (Forced cooling)
Commercial or No Commercial
Amperage in Function 7.4 A
LRA (Locked Rotor Amps) 38.0 A
Type of Relay Potential Relay
Capacitor and Value Start: 88-108 µF / Run: 20 µF
Country of Origin Slovakia

Compressor Replacements (Same Refrigerant: R407C)

  1. Embraco NJ7240E
  2. Tecumseh CAJ4511Z
  3. Danfoss MTZ22-4VI (With slight modification)
  4. Bristol H23A353DBEA
  5. Copeland ZP31KSE-PFV

Compressor Replacements (Other Refrigerant: R404A/R134a)

  1. Embraco NJ9238GK (R404A – HBP)
  2. Tecumseh TAG4546Z (R404A)
  3. Aspera NJ6226Z (R134a – requires larger displacement)
  4. Danfoss SC18G (R134a – lower capacity)
  5. Copeland ZB15KCE-TFD (R404A – Scroll version)

Mastering High-Performance Cooling: The Aspera J7238GE Professional Overview

In the world of commercial refrigeration and industrial climate control, the Aspera J7238GE stands as a testament to Slovakian engineering precision. This 1.5 HP powerhouse is specifically designed for High Back Pressure (HBP) applications, making it a “go-to” choice for engineers managing large-scale walk-in coolers, industrial water chillers, and specialized air conditioning units.

Operating on R407C, an environmentally conscious HFC blend, the J7238GE provides a robust cooling capacity exceeding 13,000 BTU/h. Unlike standard household compressors, this unit utilizes a CSR (Capacitor Start – Run) motor configuration. This ensures high starting torque, allowing the compressor to kick in even under heavy thermal loads without tripping the thermal protection.

For the field worker, the reliability of the Slovakia-made Embraco/Aspera line is legendary. It handles the stresses of fluctuating ambient temperatures with grace, provided the maintenance of the forced-air cooling system is kept in check.

Efficiency Metrics (COP) & Performance Curve

The efficiency of the J7238GE is highly dependent on the evaporating temperature. Below is the performance data for R407C at a standard Condensing Temperature of 45°C.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-10 1,950 1,210 1.61
-5 2,480 1,350 1.84
0 3,110 1,480 2.10
+5 3,845 1,620 2.37
+7.2 4,200 1,680 2.50
+10 4,680 1,750 2.67

Engineering Insight: R407C vs. R22 and R404A

When comparing the J7238GE to older R22 models or newer R404A units, several factors emerge:

  • Glide: R407C has a significant temperature glide. As an engineer, you must ensure the system is charged in the liquid phase to maintain the correct blend ratio.
  • Heat Transfer: R407C offers excellent heat transfer coefficients in HBP ranges, often outperforming R134a in similar physical footprints.
  • Displacement: With a 32.7 cc displacement, the J7238GE moves a significant volume of gas, making it far more efficient for medium-to-large commercial cabinets than the standard NJ series used in smaller retail fridges.

Maintenance and Field Advice

  1. Oil Management: This compressor uses POE oil. It is extremely hygroscopic (absorbs moisture quickly). Never leave the system open to the atmosphere for more than 15 minutes.
  2. Start Components: Always check the potential relay and capacitors if the compressor hums but fails to start. A weakened 20µF run capacitor is often the silent killer of these motors.
  3. Vibration: Ensure the mounting grommets are secure. The J7238GE is a heavy-duty reciprocating model; excessive vibration can lead to copper fatigue and subsequent leaks.

Focus Keyphrase: Aspera J7238GE Compressor 1.5 HP R407C HBP Technical Specifications and Performance Data

SEO Title: Mbsm.pro – Aspera J7238GE Compressor | 1.5 HP | R407C | HBP Expert Guide

Meta Description: Discover the full technical specs of the Aspera J7238GE 1.5 HP compressor. Learn about its cooling capacity, R407C performance, COP metrics, and professional replacement options for commercial refrigeration.

Slug: aspera-j7238ge-compressor-1-5-hp-r407c-hbp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Aspera, Embraco, J7238GE, 963HA01, R407C, 1.5HP, HBP, Commercial Cooling, NJ7240E, CAJ4511Z, MTZ22, NJ9238GK, Refrigeration Repair, HVAC Engineering.

Excerpt: The Aspera J7238GE is a powerhouse in the commercial cooling sector. Delivering 1.5 HP of performance using R407C refrigerant, this Slovakia-built compressor is designed for High Back Pressure applications. With a 32.7 cc displacement and a robust CSR motor, it provides reliable cooling for large-scale industrial chillers and commercial walk-in refrigeration systems worldwide.

spera J7238GE Compressor 1.5 HP R407C HBP Technical Specifications and Performance Data mbsmpro
1.5HP, 963HA01, Aspera, CAJ4511Z, Commercial Cooling, Embraco, HBP, J7238GE, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, MTZ22, NJ7240E, NJ9238GK, R407C, Refrigeration Repair



I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line?

I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line? mbsmpro

Focus Keyphrase: Refrigerator Suction Line Frost and Capillary Tube Length Optimization

SEO Title: Mbsm.pro, Impact of Capillary Tube Length on Suction Line Frosting

Meta Description: Is a 2-meter capillary tube causing ice on your suction line? Learn how capillary length, diameter, and refrigerant charge affect compressor health and cooling efficiency.

Slug: refrigerator-capillary-tube-length-frost-suction-line

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Capillary Tube, Refrigeration Repair, Suction Line Frost, Compressor Maintenance, R134a, R600a, HVAC Technician Tips

Excerpt: Troubleshooting frost on a refrigerator’s suction line requires a deep understanding of pressure drops. If a 2-meter capillary tube was recently installed, it might be the primary culprit behind liquid floodback. This article explores the technical relationship between expansion device length, refrigerant flow, and the critical balance needed to protect the compressor from terminal damage.


Mbsm.pro, Refrigeration, Capillary Tube, 2 Meters, Suction Line Frost, R134a, R600a, Compressor Protection

In the world of field refrigeration, precision is the difference between a long-lasting appliance and a catastrophic compressor failure. One of the most common issues encountered after a capillary tube replacement is the appearance of <u>heavy frost or ice on the suction (return) line</u>. While many technicians immediately jump to the conclusion of an overcharge, the physical dimensions of the capillary tube—specifically a length of 2 meters—often play a more significant role than realized.

The Physics of Restriction: Why Length Matters

The capillary tube acts as the fixed orifice expansion device. Its job is to create a specific “restriction” or pressure drop between the high-pressure condenser side and the low-pressure evaporator side. This restriction is governed by three variables: <u>Internal Diameter (ID)</u><u>Total Length</u>, and the <u>Friction Factor</u> of the refrigerant.

When a technician installs a capillary tube that is too short (such as 2 meters for a system designed for 3 meters), the following sequence occurs:

  1. Reduced Resistance: The shorter path offers less friction.
  2. Increased Mass Flow: More liquid refrigerant enters the evaporator than the system can effectively boil off.
  3. Liquid Floodback: Because the evaporator cannot convert all the liquid to gas, the “excess” liquid refrigerant exits the evaporator and enters the suction line.
  4. Frost Formation: The liquid refrigerant continues to boil inside the suction pipe, absorbing heat from the ambient air and causing moisture to freeze instantly on the exterior of the pipe.

Technical Comparison: Capillary Requirements by Compressor Capacity

To understand why 2 meters might be insufficient, let us look at standard industry benchmarks for R134a systems (the most common domestic setup).

Compressor Horsepower (HP) Recommended Length (Meters) Standard Diameter (Inches) Typical Result of 2m Length
1/10 HP to 1/8 HP 3.0m – 3.5m 0.026 – 0.028 Severe Frost / Slugging
1/6 HP to 1/5 HP 2.8m – 3.2m 0.031 Moderate Frost on Return
1/4 HP to 1/3 HP 2.5m – 3.0m 0.036 Marginal Balance

Analysis of the 2-Meter Installation

If you have utilized a 2-meter capillary, you are likely operating at a length that is 20% to 40% shorter than the engineering specifications for most domestic refrigerators.

  • Scenario A: If the diameter is wide (e.g., 0.036″), 2 meters will almost certainly cause ice on the suction line because the “restriction” is too weak.
  • Scenario B: If the diameter is very narrow (e.g., 0.026″), 2 meters might work, but it is still risky as it leaves no room for error in the refrigerant charge.

The “Overcharge” Illusion

A significant trap for field workers is attempting to “fix” the suction line frost by removing refrigerant. While this may clear the frost, it often results in an <u>underfed evaporator</u>, meaning the freezer will not reach the desired -18°C or -24°C. The system becomes inefficient, and the compressor runs longer, increasing electricity consumption.

Comparative Symptoms: Capillary Length vs. Refrigerant Overcharge

Symptom Short Capillary (2m) Refrigerant Overcharge
Suction Line Frosted / Icy Sweating or Icy
Condenser Temp Lower than normal Extremely Hot
Evaporator Pattern Partial Frosting / Uneven Full Frosting
Amperage Draw Higher than nominal Significantly High
Cooling Speed Slow pull-down Rapid but unstable

Expert Engineering Notice and Advice

As an expert who has spent years diagnosing these cycles, I strongly advise the following “Rule of Thumb” for field repairs:

  1. <u>Always Match the Original:</u> If the original capillary was 3 meters, do not settle for 2 meters. The extra length provides the necessary “buffer” to ensure only superheated vapor reaches the compressor.
  2. <u>The Suction-Capillary Heat Exchanger:</u> Ensure that the capillary tube is soldered or wrapped tightly around the suction line for at least 1 meter. This sub-cools the liquid and helps evaporate any liquid returning in the suction line, preventing frost.
  3. <u>Vacuum is King:</u> When changing a capillary, a deep vacuum (below 500 microns) is mandatory. Any moisture left in the system will freeze at the exit of your new 2-meter tube, causing a partial blockage that mimics a “short capillary” symptom.

Final Engineering Verdict

2-meter capillary tube is generally too short for standard 1/6 to 1/4 HP domestic refrigerators using R134a. This lack of length reduces the pressure drop, leading to liquid refrigerant exiting the evaporator. To resolve this without replacing the tube again, you can try:

  • Adding a “pigtail” or extension to the capillary to reach at least 3 meters.
  • Ensuring maximum thermal contact between the capillary and the suction line.
  • Precisely weighing the charge according to the manufacturer’s nameplate (grams/ounces) rather than relying on pressure gauges alone.

I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line? mbsmpro
Capillary Tube, Compressor Maintenance, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, R600a, Refrigeration Repair, Suction Line Frost



Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL

Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL mbsmpro

Mbsmpro.com, Compressor, GQY80AT vs ATA72XL, 1/4 hp – 1/5 hp, ZEL, Huaguang, R134a, Cooling, 220V, LBP, Refrigerator Repair


Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL

In the world of refrigeration maintenance and professional appliance repair, choosing the right compressor is the difference between a long-lasting fix and a premature system failure. Today, we are diving deep into the technical specifications of two widely used units in the industry: the ZEL GQY80AT and the Huaguang ATA72XL. Both are designed for R134a refrigerant but serve slightly different cooling capacities and applications.

The GQY80AT, manufactured by Zanussi Elettromeccanica (ZEL), has long been a staple in European-designed domestic freezers and large refrigerators. It is a robust 1/4 HP unit known for its high starting torque and reliability in fluctuating voltage environments. On the other hand, the Huaguang ATA72XL is a highly efficient 1/5 HP+ (often treated as a strong 1/5 or light 1/4) compressor from the Wanbao Group. It is frequently seen in modern energy-efficient refrigerators where low noise and high Coefficient of Performance (COP) are prioritized.

Technical Specification Table

Model ZEL GQY80AT Huaguang ATA72XL
Utilization LBP (Low Back Pressure) LBP (Low Back Pressure)
Domaine Freezing / Cooling Freezing / Cooling
Cooling Wattage (-23.3°C) 198 W 185 W
Cubic Feet Capacity 12 – 16 cu.ft. 10 – 14 cu.ft.
Liters Capacity 350 – 450 L 280 – 400 L
Kcal/h 170 kcal/h 159 kcal/h
Oil Type & Quantity POE (Ester) / 200ml POE (Ester) / 180ml
Horsepower (HP) 1/4 HP 1/5 HP+
Refrigerant Type R134a R134a
Power Supply 200-220V / 50Hz 220-240V / 50-60Hz
Cooling Capacity (BTU) 676 BTU/h 631 BTU/h
Motor Type RSIR / RSCR RSIR
Displacement 8.1 cm³ 7.2 cm³
Winding Material Copper Copper
Pressure Charge 0.5 – 0.8 Bar (Running) 0.4 – 0.7 Bar (Running)
Capillary Size 0.031″ / 3.0m 0.028″ / 3.0m
Temperature Function -35°C to -10°C -30°C to -10°C
Cooling Method Static (No Fan) Static (No Fan)
Commercial Use Light Commercial/Domestic Domestic
Amperage (FLA) 1.3 A 1.1 A
LRA (Locked Rotor) 12 A 10 A
Relay Type PTC PTC
Capacitor Optional (4-5uF) No
Origin China (Zanussi Tech) China (Wanbao)

Efficiency Metrics (COP) Performance Data

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-30 145 125 1.16
-25 182 148 1.23
-23.3 (Standard) 198 155 1.27
-20 235 170 1.38
-15 305 195 1.56
-10 390 220 1.77

Professional Replacement Guide

When the original unit is no longer available, these replacements offer the same displacement and cooling curve characteristics.

5 Direct Replacements (R134a Gas)

  1. Embraco FFI7.5HAK: A heavy-duty 1/4 HP equivalent with high reliability.
  2. Secop (Danfoss) TLES7F: Excellent efficiency for domestic LBP applications.
  3. LG MA72LAEP: A very quiet alternative with similar mounting footprints.
  4. Tecumseh THG1365YS: Known for high tolerance to high ambient temperatures.
  5. Samsung NC44A94ALH: A compact but powerful alternative.

5 Alternative Replacements (R600a Gas Conversion)

Note: Converting to R600a requires a complete system flush and a dedicated R600a capillary/filter.

  1. Secop TLES7.5KK.4: The industry standard for R600a 1/4 HP swaps.
  2. Embraco EMX70CLC: High COP unit for energy-conscious repairs.
  3. Jiaxipera NT1114Y: Widely used in modern inverter-to-fixed-speed conversions.
  4. Donper LU72CZ1: A budget-friendly R600a unit with stable performance.
  5. Wanbao ATA72XL (R600a Version): The direct isobaric sibling of the R134a model.

Expert Engineering Insights & Tips

When installing these compressors, pay close attention to the displacement differences. The GQY80AT (8.1cc) is slightly more powerful than the ATA72XL (7.2cc). If you are replacing a ZEL with a Huaguang, the cooling might be slightly slower in a large chest freezer. Conversely, using a ZEL to replace a Huaguang may result in shorter cycle times, which can lead to higher wear on the relay if not monitored.

Technician’s Checklist:

  • Triple Vacuum: Always pull down to 500 microns to ensure all moisture is removed from the POE oil.
  • Filter Drier: Never reuse a filter. Always install a new 20g or 30g XH-9 molecular sieve drier.
  • Winding Check: Before brazing, verify the Common, Start, and Main terminals. The GQY80AT has a standard triangular pin configuration.
  • Heat Dissipation: Ensure the condenser coils are cleaned. These static-cooled compressors rely heavily on natural convection or the external cabinet skin for heat exchange.

Focus Keyphrase: ZEL GQY80AT and Huaguang ATA72XL Compressor Specifications and Replacement Guide

SEO Title: Mbsmpro.com, Compressor, GQY80AT, ATA72XL, 1/4 HP, R134a, Technical Data

Meta Description: Detailed technical analysis of ZEL GQY80AT and Huaguang ATA72XL compressors. Includes BTU, wattage, cooling capacity, and 10 professional replacement models for R134a and R600a. Perfect for refrigeration engineers and professional technicians.

Slug: zel-gqy80at-huaguang-ata72xl-compressor-specs-replacement

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, ZEL, GQY80AT, Huaguang, ATA72XL, R134a, 1/4 HP, 1/5 HP, Embraco FFI7.5HAK, Secop TLES7F, LG MA72LAEP, Tecumseh THG1365YS, Refrigeration Repair, Compressor Replacement, LBP Compressor

Excerpt: Choosing between the ZEL GQY80AT and Huaguang ATA72XL requires a deep understanding of displacement and cooling wattage. This professional guide breaks down the 198W capacity of the GQY80AT versus the 185W of the ATA72XL, providing essential data for technicians, including oil types, motor configurations, and a comprehensive list of cross-compatible replacement models.




Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide mbsmpro

Mbsmpro.com, Compressor, Secop, TLES6FT.3, 1/5 HP, R134a, Cooling, 149 W, 1.1 A, 1Ph 220-240V 50Hz, LBP, RSIR/CSIR, Slovakian Engineering


When it comes to domestic refrigeration, few names carry as much weight as Secop. Formerly known under the Danfoss brand, these Slovakian-made powerhouses have become the backbone of reliable household cooling. Today, we’re breaking down the TLES6FT.3, a Low Back Pressure (LBP) compressor designed for efficiency and long-term durability in R134a systems.

If you’re a technician in the field, you know that the TLES series is prized for its compact footprint and low noise levels. It’s a “set it and forget it” component that handles the rigorous demands of modern energy standards without breaking a sweat.


Technical Data & Performance Specifications

The following data provides a granular look at the mechanical and electrical heart of this unit.

Feature Specification
Model TLES6FT.3
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Cooling
Cooling Wattage (-23.3°C) 149 Watts (ASHRAE)
Cooling Capacity (BTU/h) 508 BTU/h
Cubic Feet Capacity Approx. 7 to 9.5 cu. ft.
Liters Capacity 200 – 270 Liters
Kcal/h 128 Kcal/h
Oil Type and Quantity POE (Polyolester) / 180 ml
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V / 50Hz / 1 Phase
Motor Type RSIR/CSIR (Depending on Starter)
Displacement 5.70 cm³
Winding Material Copper
Pressure Charge Low Pressure (Suction Side)
Capillary Tube (Suggested) 0.031″ ID x 3 meters (Approx.)
Appliance Type Refrigerators, Deep Freezers
Operating Temp Range -35°C to -10°C
Cooling Method Static (No Fan Required)
Commercial Class Domestic / Light Commercial
Amperage (RLA) 0.95 A – 1.1 A
Locked Rotor Amps (LRA) 7.5 A
Start Relay PTC or Electromagnetic
Run Capacitor Optional (usually not required for RSIR)
Country of Origin Slovakia

Efficiency Metrics (COP) & Performance Curve

Efficiency is where the TLES6FT.3 truly shines. The Coefficient of Performance (COP) varies based on the evaporating temperature. Use this table for precise diagnostics during system charging.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 82 88 0.93
-30 110 102 1.08
-23.3 (Standard) 149 122 1.22
-20 172 134 1.28
-15 215 150 1.43
-10 268 168 1.60

Wiring & Connection Schematic

For the electrics, the TLES6FT.3 utilizes a standard triangular pin configuration. Proper wiring is essential to prevent winding burnout.

  • Common (C): Top Pin.
  • Run (R): Bottom Right Pin.
  • Start (S): Bottom Left Pin.
  • Logic: The PTC starter bridges the Start and Run windings briefly to initiate rotation. If using a CSIR setup, a start capacitor (usually 60-80 µF) is placed in series with the start winding.

Cross-Reference & Replacement Guide

If the TLES6FT.3 is unavailable, these alternatives offer similar displacement and BTU output.

Direct R134a Replacements (Same Gas)

  1. Embraco: EMS 55 HLC / EMYe 70 CLP
  2. ZMC/Zem: GL60AA
  3. ACC / Cubigel: GVY57AA
  4. Huayi: HYE60MT
  5. Tecumseh: THB1355Y

R600a Conversion Alternatives (Requires System Flush)

Note: Converting from R134a to R600a requires a complete change of the capillary tube and filter drier.

  1. Secop: TLY5.7KK.3
  2. Embraco: EMX55CLC
  3. Jiaxipera: T1114Y
  4. Sikap: HMK95AA
  5. Donper: L72CZ1

Expert Insight: Installation & Maintenance Notice

As a field engineer, I’ve seen these units last 15+ years when installed correctly. The TLES6FT.3 is a “high-tolerance” unit, but it is sensitive to moisture. Because it uses POE oil, which is highly hygroscopic (absorbs water), you must keep the system sealed until the very moment of brazing.

  • Pro-Tip: Always replace the filter drier when swapping this compressor. A 15g or 20g drier is standard for this capacity.
  • Vacuuming: Do not skip the vacuum stage. A minimum of 250 microns is recommended to ensure the POE oil remains stable.
  • Charging: Charge by weight according to the refrigerator manufacturer’s label. Overcharging R134a systems will lead to high head pressure and premature valve failure.

Focus Keyphrase

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide

SEO Title

Mbsmpro.com | Secop TLES6FT.3 Compressor | 1/5 HP | R134a | LBP Guide

Meta Description

Get the technical specs for the Secop TLES6FT.3 compressor. 1/5 HP, R134a, 149W cooling capacity. Includes wiring diagrams, replacement cross-references, and expert COP tables.

Slug

secop-tles6ft-3-compressor-r134a-1-5hp-specs

Tags

Secop, TLES6FT.3, R134a, 1/5 HP, Compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Slovakia, LBP, EMS55HLC, GL60AA, GVY57AA, HYE60MT, THB1355Y, Refrigeration Repair, Danfoss Compressor

Excerpt

The Secop TLES6FT.3 is a cornerstone of modern domestic refrigeration. This 1/5 HP, R134a compressor is engineered in Slovakia for Low Back Pressure applications, offering a cooling capacity of 149W. Known for its quiet operation and energy efficiency, it is the ideal choice for medium-sized refrigerators and deep freezers looking for long-term reliability.

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide mbsmpro
1/5 hp, Compressor, EMS55HLC, GL60AA, GVY57AA, HYE60MT, LBP, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, Refrigeration Repair, Secop, Slovakia, THB1355Y, TLES6FT.3



Samsung RT47CB663222 Compressor Specifications R600a 1/5 HP Cooling Capacity Inverter Refrigerator Spare Parts

Samsung RT47CB663222 Compressor Specifications R600a 1/5 HP Cooling Capacity Inverter Refrigerator Spare Parts mbsmpro

Refrigerator & Compressor Technical Specifications

Feature Details
Model RT47CB663222
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Cooling (Dual Zone)
Cooling Wattage at -23.3°C Approx. 165 – 175 W
Cubic Feet Capacity 16.8 cu.ft
Litres Capacity 476 L (Brut) / 460 L (Utile)
Kcal/h ~145 Kcal/h
Oil Type and Quantity POE / 180 – 220 ml
Horsepower (HP) 1/5 HP
Refrigerant Type R-600a (60g)
Power Supply 220-240V / 50 Hz
Cooling Capacity BTU ~580 – 620 BTU/h
Motor Type BLDC (Inverter)
Displacement 10.0 to 12.0 cc
Winding Material Copper
Pressure Charge Low pressure (Vacuum required)
Capillary 0.028″ or 0.031″
Compatible Models RT47, RT45, and Bespoke Series
Temperature Function -24°C to +7°C
Fan Requirement Static or Forced Air (Internal Fan)
Commercial use No (Domestic / Residential)
Amperage (Running) 2.0 A (Total system max)
LRA 4.5 – 6.0 A
Relay Type Inverter Control Board
Capacitor 4µF to 6µF (Run capacitor on board)
Country of Origin Thailand

Compressor Replacements

Same Gas (R-600a)

  1. Secop NLE11KK
  2. Embraco FMXA9C
  3. Jiaxipera T1116Y
  4. Donper L118CY
  5. Huayi HYB96MHU

Different Gas (R-134a Conversion)

Note: Requires complete system flush and oil change.

  1. Embraco FFI7.5HAK
  2. ZMC GMCC GL90AA
  3. Secop TLES7.5KK.3
  4. Tecumseh THG1365YS
  5. Samsung NC4AV80 (Inverter)

Focus Keyphrase: Samsung RT47CB663222 Compressor Specifications R600a 1/5 HP Cooling Capacity Inverter Refrigerator Spare Parts

SEO Title: Mbsm.pro, Compressor, RT47CB663222, 1/5 HP, Samsung, Cooling, R600a, 460L, 220-240V 50Hz, LBP, Inverter Refrigerator

Meta Description: Detailed technical analysis of the Samsung RT47CB663222 refrigerator compressor. Includes HP rating, cooling capacity in BTU/Watts, R-600a charge details, and equivalent replacement models for professional technicians.

Slug: samsung-rt47cb663222-compressor-r600a-1-5-hp-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Samsung, RT47CB663222, R600a, Inverter Compressor, 1/5 HP, NLE11KK, FMXA9C, T1116Y, L118CY, Refrigeration Repair, Thailand Made Refrigerator.

Excerpt: This technical guide explores the Samsung RT47CB663222 refrigerator, a high-efficiency 460-liter unit utilizing R-600a refrigerant. Operating on a 220-240V 50Hz supply, this inverter-driven system is designed for Low Back Pressure applications. We break down the motor characteristics, displacement, and provide a comprehensive list of equivalent replacement compressors for modern field service and professional repairs.


Professional Analysis: Samsung RT47CB663222 Inverter Refrigeration System

Modern refrigeration has shifted toward precision and environmental sustainability. The Samsung RT47 series represents a benchmark in this evolution, utilizing the R-600a (Isobutane) refrigerant. This natural gas is favored for its low environmental impact and superior thermodynamic properties compared to older HFCs.

Efficiency Metrics (COP) & Performance Data

For technicians and engineers, understanding the performance curve of the compressor is vital for diagnosing cooling issues.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-30 115 110 1.05
-25 155 135 1.15
-23.3 (LBP Point) 172 145 1.19
-20 205 160 1.28
-15 260 185 1.41
-10 330 215 1.53

Comparative Analysis: Samsung vs. Industry Standards

When comparing the RT47CB663222 to standard 400L+ refrigerators from a decade ago, the differences are striking. Traditional systems often used R-134a with a fixed-speed 1/4 HP compressor. Samsung’s modern 1/5 HP inverter design provides:

  1. Lower Amperage: The total system draws only 2.0A max, whereas older units frequently exceeded 3.5A.
  2. Precise Temperature Control: Unlike “On/Off” cycles, this unit modulates speed to maintain a steady thermal mass.
  3. Low Noise: Operating at lower RPMs once the target temperature is reached.

Engineering Schematics and Board Control

Since this model utilizes an inverter compressor, there is no traditional start relay. Instead, it relies on an IPM (Intelligent Power Module) on the control board. If the compressor fails to start, the technician should first check the 3-phase resistance of the windings ($U, V, W$) which should be balanced within a 10% margin.

Professional Field Advice

  • Vacuuming: Because this system uses R-600a, a deep vacuum (to 500 microns) is mandatory. The gas charge is only 60g; even a 2g variance can lead to inefficiency.
  • Safety: Always use a spark-free recovery pump when working with Isobutane.
  • Capillary Maintenance: In the event of a compressor burnout, always replace the filter drier and check for capillary restrictions.
Samsung RT47CB663222 Compressor Specifications R600a 1/5 HP Cooling Capacity Inverter Refrigerator Spare Parts mbsmpro
Samsung RT47CB663222 Compressor Specifications R600a 1/5 HP Cooling Capacity Inverter Refrigerator Spare Parts mbsmpro



Comptek QD65H Compressor 1/6 HP R134a L/MBP Technical Specifications and Replacement Guide

Comptek QD65H Compressor 1/6 HP R134a L/MBP Technical Specifications and Replacement Guide mbsmpro

Yes, your conclusion regarding the compressor ports is correct based on the standard design for this category:

Pipe 1 (single top pipe): This is the discharge line, usually the thinner pipe.

Pipe 2 (opposite the discharge): This is the suction line, which has a slightly larger diameter.

Pipe 3 (next to the suction): This is the process/service line, used for charging the gas.


    Mbsmpro.com, Compressor, QD65H, 1/6 hp, Comptek, Cooling, R134a, 160 W, 1.2 A, 1Ph 220-240V 50Hz, L/MBP, RSIR, -35°C to -5°C, Cooling and Freezing

    The refrigeration industry relies heavily on the “heart” of the system: the compressor. Among the most versatile and durable options available for domestic and light commercial applications is the Comptek QD65H. This piston-driven reciprocating compressor is engineered for reliability, specifically designed to handle the thermal demands of Low and Medium Back Pressure (L/MBP) environments.

    Technical Specifications and Performance Data

    The QD65H operates on the R134a refrigerant, a global standard for domestic cooling due to its thermodynamic efficiency and safety profile. Below is the comprehensive technical breakdown:

    Feature Specification
    Model QD65H (HM Series)
    Horsepower (HP) 1/6 HP
    Displacement 6.5 $cm^3$
    Cooling Capacity (BTU/h) 546 BTU/h
    Cooling Wattage (-23.3°C) 160 W
    Motor Type RSIR (Resistive Start – Induction Run)
    Winding Material High-grade Copper
    Refrigerant Type R134a
    Power Supply 220-240V / 50Hz (1 Phase)
    Oil Type and Quantity POE/Mineral (approx. 180ml – 200ml)
    Current (Running) 1.1 A – 1.2 A
    LRA (Locked Rotor Amps) 6.5 A
    Cooling Method Static (Natural cooling, no fan required for compressor)

    Efficiency Metrics (COP) and Performance Curve

    Understanding the Coefficient of Performance (COP) is vital for energy management. The QD65H shows excellent stability across a wide range of evaporating temperatures.

    Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
    -30 110 102 1.07
    -25 142 118 1.20
    -23.3 (Standard) 160 125 1.28
    -20 185 134 1.38
    -15 230 148 1.55
    -10 285 162 1.76
    0 410 190 2.15

    Application and Capability

    This compressor is the “workhorse” for medium-sized household appliances. It is ideally suited for:

    • Capacity in Liters: Efficiently cools units between 180 to 250 Liters.
    • Capacity in Cubic Feet: Approximately 6.3 to 8.8 $ft^3$.
    • Appliance Types: Single-door refrigerators, small chest freezers, and water dispensers.

    Comparison: QD65H vs. Similar Models

    Model HP Rating Displacement Refrigerant Application
    Comptek QD65H 1/6 HP 6.5 $cm^3$ R134a L/MBP (Versatile)
    ZMC GM70AZ 1/5 HP 7.0 $cm^3$ R134a LBP (Stronger Cooling)
    Danfoss TLS6F 1/6 HP 5.7 $cm^3$ R134a LBP (High Efficiency)

    Professional Recommendations and Installation Notes

    1. Capillary Tube Selection: For R134a systems using the QD65H, a capillary tube of 0.031 inches (0.8mm) with a length of 3 meters is standard for LBP freezing applications.
    2. Vacuum Procedure: Always ensure a vacuum level of at least 500 microns to prevent moisture from reacting with the R134a oil.
    3. Thermal Protection: The QD65H features an internal or external protector. Ensure the relay (PTC type) is seated correctly to prevent winding burnout.
    4. Start Capacitor: While being an RSIR motor, in areas with unstable voltage, adding a 47-64µF start capacitor can assist in high-torque starts (HST).

    Replacement Guide (Equivalents)

    Same Refrigerant (R134a):

    1. Embraco: EMS 55HLC
    2. Danfoss/Secop: TLES6.5FT.3
    3. Huayi: HYE69MT
    4. Zanussi: GVY66AA
    5. Tecumseh: THB1355Y

    Alternative Refrigerant (R600a/R12/Other):

    Note: Requires system flush and oil check.

    1. QD65Y (R600a version)
    2. Embraco: EMX55CLC (R600a)
    3. Danfoss: TLES7.5KK.3 (R600a)
    4. GL60AA (R134a alternative)
    5. Zel: GQD65Y

    Focus Keyphrase: Comptek QD65H Compressor 1/6 HP R134a L/MBP Technical Specifications and Replacement Guide

    SEO Title: Mbsmpro.com | Comptek QD65H Compressor | 1/6 HP | R134a | L/MBP Specifications

    Meta Description: Discover the full technical data for the Comptek QD65H 1/6 HP compressor. Includes cooling capacity (160W), COP tables, R134a gas specs, and 10 cross-reference replacement models for refrigerators and freezers.

    Slug: comptek-qd65h-compressor-1-6hp-r134a-specs

    Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, QD65H, Comptek, R134a Compressor, 1/6 HP Compressor, EMS 55HLC, TLES6.5FT.3, HYE69MT, GVY66AA, THB1355Y, Refrigeration Repair, LBP Compressor.

    Excerpt: The Comptek QD65H is a high-performance 1/6 HP reciprocating compressor designed for R134a systems. Ideal for refrigerators between 180 and 250 liters, it offers a cooling capacity of 160W at -23.3°C. This professional guide covers its electrical characteristics, COP efficiency metrics, and provides a comprehensive list of equivalent models for seamless field replacement.

    Comptek QD65H Compressor 1/6 HP R134a L/MBP Technical Specifications and Replacement Guide mbsmpro
    1/6 HP Compressor, Comptek, EMS 55HLC, GVY66AA, HYE69MT, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, QD65H, R134a compressor, Refrigeration Repair, THB1355Y, TLES6.5FT.3



    LG MA57LBJG Compressor 1/6 HP R134a LBP Technical Specifications and Replacements

    LG MA57LBJG Compressor 1/6 HP R134a LBP Technical Specifications and Replacements mbsmpro

    Mbsm.pro, Compressor, MA57LBJG, 1/6 hp, LG, Cooling, R134a, 160 W, 1.2 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, Freezing

    The LG MA57LBJG is a staple in the refrigeration world, specifically engineered for low back pressure (LBP) applications. As a technician or engineer, you recognize this model by its robust build and reliability in domestic cooling. Operating on R134a refrigerant, it balances efficiency with a compact frame, making it a go-to choice for household freezers and large refrigerators.


    Technical Specifications Table

    Feature Specification Details
    Model MA57LBJG
    Utilisation LBP (Low Back Pressure)
    Domaine Freezing / Deep Cooling
    Cooling Wattage at -23.3°C 160 W
    Cubic Feet Capacity 8 – 11 cu.ft (Depending on insulation)
    Litres Capacity 220 – 300 Liters
    Kcal/h 138 Kcal/h
    Oil Type and Quantity Ester Oil (POE), 180cc
    Horsepower (HP) 1/6 HP
    Refrigerant Type R134a
    Power Supply 220-240V / 50Hz / 1Ph
    Cooling Capacity BTU 546 BTU/h
    Motor Type RSIR (Resistive Start-Inductive Run)
    Displacement 5.7 cc
    Winding Material Copper
    Pression Charge 0.5 to 1.2 Bar (Low side running)
    Capillary Recommendation 0.031″ (0.8mm) x 3 meters (approx)
    Common Application LG, Samsung, and Whirlpool Refrigerators
    Temperature Function -35°C to -10°C
    Cooling Method Natural Cooling (Static)
    Commercial Status Residential / Light Commercial
    Amperage (RLA) 0.9 A – 1.2 A
    LRA (Locked Rotor Amps) 6.5 A
    Type of Relay PTC Relay
    Capacitor Usually Not Required (RSIR)
    Origin/Export Made in China / Exported Globally

    Efficiency Metrics (COP) & Performance

    Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
    -30 115 105 1.10
    -25 148 120 1.23
    -23.3 160 128 1.25
    -20 185 138 1.34
    -15 230 155 1.48
    -10 285 175 1.63

    Compressor Replacement Guide

    Top 5 Replacements (Same R134a Gas)

    1. Embraco: EMI60HER / EMT45HDR
    2. Secop (Danfoss): TLES5.7FT.3
    3. Tecumseh: THG1358YKS
    4. Samsung: SD152H-L1UA
    5. Huayi: HYB60MHU

    Top 5 Replacements (Alternative Gas – R600a Conversion Required)

    1. LG: CMA057LHEG
    2. Embraco: EMX55CLC
    3. Secop: TLES5.7KK.3
    4. ACC: HMK80AA
    5. Donper: S65CY

    Note: Replacing R134a with R600a requires a complete system flush, change of oil, and a specific R600a charging procedure due to flammability.


    Engineering Insights: Comparison & Benefits

    When compared to the slightly more powerful MA62LJJG (1/5 HP), the MA57LBJG offers a higher energy efficiency ratio for mid-sized units. While the 1/5 HP model provides faster pull-down times, the MA57LBJG is optimized for maintaining steady-state freezing temperatures with lower electrical overhead.

    Why use this model?

    • Copper Windings: Unlike some newer aluminum-wound budget models, the copper internals of the MA57LBJG ensure better thermal conductivity and longer life under high-heat conditions.
    • Low Vibration: The internal spring mounting is tuned specifically for domestic environments, ensuring whisper-quiet operation.

    Professional Tips for Installation:

    Pro Tip: Always replace the filter drier when swapping this compressor. Since it uses POE oil, it is highly hygroscopic (absorbs moisture quickly). Limit the time the system is open to the atmosphere to under 15 minutes.


    Focus Keyphrase: LG MA57LBJG Compressor 1/6 HP R134a LBP Technical Specifications and Replacements

    SEO Title: Mbsm.pro – MA57LBJG LG Compressor 1/6 HP R134a Data Sheet

    Meta Description: Discover the full technical specifications for the LG MA57LBJG compressor. 1/6 HP, R134a, LBP. Includes cooling capacity, COP tables, and 10 compatible replacement models for technicians.

    Slug: lg-ma57lbjg-compressor-1-6-hp-r134a-specs

    Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, MA57LBJG, LG Compressor, 1/6 HP, R134a, LBP, EMI60HER, TLES5.7FT.3, THG1358YKS, SD152H, HYB60MHU, Refrigeration Repair, Compressor Cross Reference

    Excerpt: The LG MA57LBJG is a high-performance 1/6 HP compressor designed for R134a refrigerant in Low Back Pressure (LBP) applications. Ideal for domestic freezers, it delivers 160W of cooling capacity at -23.3°C. This guide provides comprehensive technical data, winding details, and a full cross-reference list for professional refrigeration technicians and engineers.

    LG MA57LBJG Compressor 1/6 HP R134a LBP Technical Specifications and Replacements mbsmpro
    1/6 HP, EMI60HER, HYB60MHU, LBP, LG compressor, MA57LBJG, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, Refrigeration Repair, SD152H, THG1358YKS, TLES5.7FT.3



    Panasonic QB86C18GAX5: The Reliable Powerhouse of Tropical Refrigeration

    Panasonic QB86C18GAX5: The Reliable Powerhouse of Tropical Refrigeration mbsmpro

    Mbsmpro.com, Compressor, QB86C18GAX5, 1/4 hp, Panasonic, Cooling, R134a, 201 W, 1Ph, 220-240V 50Hz, LBP, RSIR, -35°C to -15°C, Freezing


    Technical Specifications Table

    Feature Details
    Model QB86C18GAX5
    Utilisation LBP (Low Back Pressure)
    Domaine Freezing / Deep Cooling
    Oil Type and Quantity Ester Oil (POE) / 230 ml
    Horsepower (HP) 1/4 HP
    Refrigerant Type R134a
    Power Supply 220-240V / 50Hz / 1PH
    Cooling Capacity BTU 686 BTU/h (approx. 201W)
    Motor Type RSIR (Resistance Start – Induction Run)
    Displacement 8.6 cm³
    Winding Material Copper
    Pressure Charge 0.4 to 1.1 Bar (Suction Side)
    Capillary Recommendation 0.036″ / 0.042″ (Dependent on cabinet size)
    Refrigerator Models Large domestic side-by-side, Chest Freezers, Display Chillers
    Temperature Function -35°C to -15°C
    Fan Requirement Optional (Static cooling usually sufficient)
    Commercial Use Light Commercial / Domestic High-Capacity
    Amperage (RLA) 1.1A – 1.3A
    LRA (Locked Rotor Amps) 8.0A
    Type of Relay PTC Relay
    Capacitor N/A (Standard RSIR)

    Compressor Cross-Reference (Same Gas – R134a)

    1. Embraco: EGAS80HLR / FFI8.5HAK
    2. Danfoss/Secop: TLES8.7F / NLE8.8FT
    3. LG: MA88LAEP
    4. Tecumseh: THG1374YS
    5. Samsung: SK182H-L2U

    Compressor Cross-Reference (Alternative Gas – R600a)

    1. Panasonic: QB86C18GAX5 (R134a specific, use QB91 series for R600a equivalent)
    2. Embraco: EM2X1121U
    3. Secop: NLE11KK
    4. Jiaxipera: NT1114Y
    5. Donper: LU111CY

    Panasonic QB86C18GAX5: The Reliable Powerhouse of Tropical Refrigeration

    In the demanding world of refrigeration, the Panasonic QB series has established itself as a benchmark for durability and thermal resilience. The QB86C18GAX5, a 1/4 HP unit, is a staple in high-capacity domestic refrigerators and light commercial freezers. Designed to operate under Low Back Pressure (LBP) conditions, this compressor is particularly favored in regions with high ambient temperatures due to its superior heat dissipation and robust motor design.

    Performance and Efficiency

    With a displacement of 8.6cc, the QB86C18GAX5 strikes a perfect balance between power consumption and cooling velocity. It provides a cooling capacity of approximately 201 Watts (686 BTU/h), which is the sweet spot for large family refrigerators or chest freezers. The RSIR (Resistance Start – Induction Run) motor ensures a simple electrical setup, reducing the points of failure compared to systems requiring complex start/run capacitors.

    Comparison: Panasonic vs. Embraco & Secop

    While the Embraco EGAS80HLR is often cited as a direct competitor, the Panasonic QB86C18GAX5 often wins on mechanical silence. Panasonic’s internal damping system is specifically engineered to reduce “knocking” sounds during the start-stop cycle. Compared to the Secop TLES8.7F, the Panasonic unit tends to handle voltage fluctuations slightly better, a critical factor for field technicians working in areas with unstable power grids.

    Professional Installation & Maintenance Tips

    • Oil Sensitivity: This compressor uses POE (Ester) oil. This oil is extremely hygroscopic (absorbs moisture quickly). Never leave the compressor open to the atmosphere for more than 10 minutes during installation.
    • Vacuuming Protocol: A deep vacuum is non-negotiable. Moisture mixed with POE oil creates acid that will etch the copper windings and lead to a “grounded” compressor.
    • Filter Drier Replacement: Always use a high-quality 20g or 30g drier. Given the 1/4 HP power, a larger drier ensures a cleaner system for a longer lifespan.

    Focus Keyphrase: Panasonic QB86C18GAX5 Compressor 1/4 HP R134a Specs

    SEO Title: Mbsm.pro – Panasonic QB86C18GAX5 Compressor: 1/4 HP, R134a, Technical Data

    Meta Description: Full technical review of the Panasonic QB86C18GAX5 compressor. 1/4 HP, R134a, 201W cooling capacity. Ideal for domestic refrigerators and freezers. Find equivalents and installation tips.

    Slug: panasonic-qb86c18gax5-compressor-1-4hp-r134a-specifications

    Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Panasonic, QB86C18GAX5, 1/4 HP, R134a, LBP, EGAS80HLR, FFI8.5HAK, TLES8.7F, MA88LAEP, THG1374YS, SK182H-L2U, Refrigeration Repair, Compressor Replacement.

    Excerpt: The Panasonic QB86C18GAX5 is a 1/4 HP reciprocating compressor engineered for high-efficiency Low Back Pressure (LBP) applications. Using R134a refrigerant and a displacement of 8.6cc, it delivers a cooling capacity of 201W. This guide provides technicians with essential technical data, including amperage, displacement, and a comprehensive cross-reference list for modern repairs.

    Panasonic QB86C18GAX5: The Reliable Powerhouse of Tropical Refrigeration mbsmpro
    Panasonic QB86C18GAX5: The Reliable Powerhouse of Tropical Refrigeration mbsmpro



    Role of Current Relays in Compressor Ignition

    Role of Current Relays in Compressor Ignition mbsmpro

    Mbsmpro.com, Compressor Spare Parts, Relays, Thermal Overload Protectors, 1/2 hp to 1/6 hp, Start and Protection Stems, Characteristic Tables

    Selecting the right electrical components is the heartbeat of refrigeration maintenance. When a compressor fails to start or constantly trips, the culprit is often a mismatched Current Relay or a fatigued Thermal Overload Protector. Ensuring these parts align perfectly with the compressor’s horsepower (HP) and amperage rating is not just about repair—it is about system longevity.

    The Role of Current Relays in Compressor Ignition

    Current relays are electromagnetic switches that momentarily engage the start winding of a compressor. Once the motor reaches approximately 75% of its rated speed, the relay disconnects the start winding, allowing the motor to run on its main winding.

    Technical Specifications for Standard Current Relays

    Model Compressor Power (HP) Terminal Pin Applied Current (A)
    117U 2010 1/3 HP 5 4.5 A
    117U 2100 1/4 HP 6 3.6 A
    117U 2104 1/5 HP 4 6.5 A
    117U 2050 1/2 HP 1 1.4 A

    Thermal Overload Protectors: The Safety Net

    Thermal Overload Protectors (TOP) act as a bimetallic fuse. They monitor both the heat generated by the compressor and the current flowing through it. If the compressor stalls (locked rotor) or overheats due to a refrigerant leak, the TOP breaks the circuit to prevent the motor windings from melting.

    Performance Benchmarks for Overload Protectors

    Compressor Power (HP) Max Connect Current (A) Release Current (A)
    1/2 HP 12.5 A 5.0 A
    1/3 HP 9.0 A 4.75 A
    1/4 HP 8.0 A 4.0 A
    1/5 HP 7.5 A 3.5 A
    1/6 HP 7.0 A 3.0 A

    Comparison: Mechanical Relays vs. PTC Starters

    While the technical data above focuses on mechanical current relays, modern systems often use PTC (Positive Temperature Coefficient) starters.

    • Mechanical Relays (117U Series): Highly reliable for heavy-duty applications. They provide a “snap” action that is better for high-torque starts.
    • PTC Starters: Use a solid-state disk that increases resistance as it heats up. They are quieter but require a cool-down period before the compressor can restart.

    Engineering Advice for Field Technicians

    1. Never Oversize the Protector: If you install a 1/2 HP protector on a 1/6 HP compressor, the protector will not trip during a fault, leading to a burnt-out compressor.
    2. Check the Return Temperature: Thermal caps must operate within a return temperature range of 60 ± 10°C. Anything higher indicates a system restriction or lack of airflow over the condenser.
    3. Terminal Integrity: Ensure terminals are tight. A loose connection creates resistance, which generates heat and causes “nuisance tripping” of the overload.

    Focus Keyphrase: Compressor Current Relay and Thermal Overload Protector Characteristic Tables for 1/2 to 1/6 HP

    SEO Title: Mbsmpro.com | Compressor Start Relays & Thermal Overload Tables

    Meta Description: Comprehensive guide to compressor start and protection stems. Technical tables for 117U relays and thermal overload protectors from 1/2 HP to 1/6 HP. Essential data for HVAC engineers.

    Slug: compressor-relay-thermal-overload-characteristic-tables

    Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Compressor Parts, Start Relay, Thermal Overload, Refrigeration Repair, 117U Relay, HVAC Engineering, Compressor Protection.

    Excerpt: Selecting the right electrical components is the heartbeat of refrigeration maintenance. When a compressor fails to start or constantly trips, the culprit is often a mismatched Current Relay or a fatigued Thermal Overload Protector. Ensuring these parts align perfectly with the compressor’s horsepower (HP) and amperage rating is vital for long-term system reliability.

    Role of Current Relays in Compressor Ignition mbsmpro
    Role of Current Relays in Compressor Ignition mbsmpro



    Embraco NEU2178GK, compressor

    Embraco NEU2178GK, compressor mbsmpro

    Mbsmpro.com, Embraco, NEU2178GK, 1 HP, LBP, R404A, 220-240V, 50Hz, 16.8 cc, CSR, Commercial Freezer Compressor


    The Cold Heart of Commercial Freezing: Embraco NEU2178GK

    If you are an artisan bricoleur or a refrigeration technician working on commercial island freezers or restaurant reach-ins, you have likely encountered the Embraco NEU2178GK. This isn’t your standard domestic fridge compressor; this is a 1 HP powerhouse designed for the heavy lifting required by Low Back Pressure (LBP) applications using R404A or R507 refrigerant.

    Known for its robust “Made in Slovakia” build, the NEU2178GK is a CSR (Capacitor Start, Capacitor Run) motor. This is a critical detail for technicians: unlike simpler PTCSCR compressors, this unit relies on a precise electrical box containing both a start capacitor and a run capacitor to manage its high starting torque (HST). It is the engine you choose when you need reliability in a -30°C environment.

    Why the “GK” Matters

    In Embraco’s nomenclature, the “K” at the end (as in NEU2178GK) often signifies a specific motor type—in this case, one designed for High Starting Torque. This means it can restart even if pressures haven’t fully equalized, a common scenario in busy commercial kitchens where doors are opened frequently.


    Technical Specifications: The Data You Need

    Here is the breakdown of the technical capabilities of this compressor.

    Feature Specification
    Model NEU2178GK
    Brand Embraco (Nidec)
    Horsepower (HP) 1 HP
    Displacement 16.80 cm³ (cc)
    Refrigerant R404A / R507 / R452A
    Application LBP (Low Back Pressure)
    Voltage 220-240V ~ 50Hz
    Cooling Capacity ~900 W (at -23.3°C ASHRAE)
    Motor Type CSR (Capacitor Start & Run)
    Start Capacitor 88 – 108 µF / 330V
    Run Capacitor 15 µF / 400V
    Oil Type POE 22 (Polyolester)
    Oil Charge 350 ml
    Expansion Device Capillary or TXV (Expansion Valve)

    Exploitation: Installation Tips for the Artisan

    Installing a 1 HP commercial compressor is different from swapping a domestic one. Here are the “golden rules” for the NEU2178GK:

    1. The Electric Box is Mandatory: You cannot bypass the capacitor box. This motor needs the 15µF run capacitor to maintain efficiency and keep the windings cool, and the start capacitor to kick the rotor into motion against high head pressure.
    2. Moisture is the Enemy: This compressor comes filled with POE oil. POE is like a sponge for humidity. If you leave the plugs open for more than 15 minutes, the oil absorbs moisture that vacuum pumps cannot remove. Keep it sealed until the last second.
    3. Nitrogen Sweep: Because R404A systems use POE oil, any carbon from brazing will turn into sludge and block the capillary tube immediately. Always braze with a trickle of nitrogen flowing through the pipes.
    4. R452A Compatibility: If R404A is expensive or restricted in your area, this compressor is often compatible with R452A, a drop-in replacement with a lower GWP (Global Warming Potential), but always check the discharge temperature.

    Comparison: Embraco NEU2178GK vs. The Competition

    When you can’t find the exact Embraco model, you need a replacement. Here is how it stacks up against the heavyweights from Secop and Tecumseh.

    Compressor Brand Approx. HP Displacement Verdict
    NEU2178GK Embraco 1 HP 16.8 cc Best for high-torque commercial freezers.
    SC21CL Secop (Danfoss) ~7/8 – 1 HP 20.95 cc Older design, physically larger, very reliable.
    CAJ2464Z Tecumseh 1.5 HP 34.4 cc Much more powerful; usually overkill for this slot.
    NT2180GK Embraco 1 HP 20.4 cc The “big brother” of the NEU series; fits if you have space.

    Pro Tip: If replacing a Secop SC21CL with this Embraco NEU2178GK, you may need to adjust the pipework as the Embraco is slightly more compact (lower height: ~206mm vs Secop ~219mm).


    Performance Analysis: Power Consumption

    One reason technicians love the NEU series is efficiency.

    • Current (Amps): At typical freezer conditions (-25°C), it draws about 4.3 Amps.
    • LRA (Locked Rotor Amps): 21.0 A. If your clamp meter reads 21A instantly and stays there, your compressor is mechanically seized or the start capacitor is dead.

    Performance Analysis: Power Consumption

    One reason technicians love the NEU series is efficiency.

    • Current (Amps): At typical freezer conditions (-25°C), it draws about 4.3 Amps.
    • LRA (Locked Rotor Amps): 21.0 A. If your clamp meter reads 21A instantly and stays there, your compressor is mechanically seized or the start capacitor is dead.

    Embraco NEU2178GK, compressor mbsmpro

    Focus Keyphrase: Embraco NEU2178GK 1 HP Compressor R404A

    SEO Title: Mbsmpro.com, Embraco, NEU2178GK, 1 HP, LBP, R404A, 220-240V, 50Hz, 16.8 cc, CSR, Commercial Freezer

    Meta Description: Discover the Embraco NEU2178GK 1 HP Compressor (R404A/LBP). Full technical specs, CSR wiring guide, and comparisons with Secop and Tecumseh for commercial refrigeration repairs.

    Slug: embraco-neu2178gk-1-hp-compressor-r404a-lbp-specs

    Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco NEU2178GK, 1 HP Compressor, R404A, Commercial Freezer, CSR Motor, NEU2178GK Specs, Refrigeration Repair, 16.8cc Compressor

    Excerpt: The Embraco NEU2178GK is the definitive choice for 1 HP commercial freezing applications. Featuring a robust CSR motor and 16.8cc displacement, this R404A compressor delivers high starting torque for demanding environments. This guide details the electrical requirements, installation tips, and how it compares to Secop and Tecumseh alternatives.