Embraco NEK6187Z compressor R134a 1/3 HP HBP commercial refrigeration replacement specifications technical data

Embraco NEK6187Z compressor R134a 1/3 HP HBP commercial refrigeration replacement specifications technical data mbsmpro

Embraco NEK6187Z Compressor | 1/3 HP | R134a | HBP | 220-240V 50Hz | POE Oil 380cc | Commercial Refrigeration

When you’re dealing with commercial refrigeration equipment, finding the right compressor can make or break your system. The Embraco NEK6187Z is one of those workhorse compressors you’ll find in plenty of beverage coolers, ice machines, and commercial display cases. Let’s dive into what makes this compressor tick and everything you need to know about it.

Technical Specifications Overview

Specification Details
Model NEK6187Z
Brand Embraco/Aspera
Utilisation (MBP/HBP/LBP) HBP (High Back Pressure) / MBP
Domaine (Freezing/Cooling) Cooling (Commercial Refrigeration)
Cooling Wattage at -23°C Approximately 480W
Cubic Feet Capacity 8-12 cubic feet
Litres Capacity 200-350 litres
Kcal/h 774 kcal/h (at +5°C evap)
TON 0.26 TR (approximate)
Oil Type and Quantity POE Oil 380cc (350-380ml)
Horsepower (HP) 1/3 HP
Refrigerant Type R134a
Power Supply 220-240V ~ 50Hz, 1 Phase
Cooling Capacity BTU 3,340 BTU/h (at +5°C)
Motor Type CSIR (Capacitor Start Inductor Run)
Displacement 10.0 cm³ (9.99 cc)
Winding Material Copper
Pressure Charge Delivered with dry air (~1 bar) or light vacuum
Capillary Capillary tube system
Refrigerator Models Whirlpool K40 ice machines, commercial display cases, beverage coolers
Temperature Function -15°C to +10°C evaporating range
With Fan or No Yes (fan cooling recommended – 520 m³/h)
Commercial or No Yes – Commercial grade
Amperage in Function Operating: ~1.3A, LRA: 16.1A
LRA (Locked Rotor Amps) 16.1A
Type of Relay CSIR start relay required
Capacitor Yes – Start capacitor required (starting device mandatory)
Country of Origin Slovakia
Exporting Countries Throughout Europe, Middle East, Asia-Pacific

Cooling Capacity at Different Temperatures

The NEK6187Z performs differently depending on your evaporating temperature. Here’s what you can expect

gastroparts.com:

Evaporating Temperature Cooling Capacity
-10°C 482 W
-5°C 624 W
0°C 791 W
+5°C 983 W
+10°C 1,201 W

Efficiency Metrics (COP)

Understanding the Coefficient of Performance helps you gauge efficiency at different operating conditions:

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) 280 380 420 480 580 688 900 1020 1200
Power Consumption (Watts) 320 340 350 365 390 420 480 520 580
COP 0.88 1.12 1.20 1.32 1.49 1.64 1.88 1.96 2.07

Note: COP values calculated based on EN 12900 test conditions with condensing temperature at +54.4°C for HBP applications

www.hutes-klima-technika.hu

Application Details

This compressor is built for high back pressure (HBP) applications, which means it’s designed for warmer refrigeration tasks like:

  • Beverage coolers
  • Display cases
  • Ice machines
  • Wine coolers
  • Commercial refrigerators

The unit features high starting torque (HST), which is crucial for commercial applications where you might have hard starting conditions

www.skh-kaeltetechnik.de. The CSIR motor design provides reliable performance, though it does require a starting device – the label clearly states “NO START WITHOUT STARTING DEVICE” for a reason

crwltd.co.uk.

Physical Characteristics

  • Connection Type: Tube-to-tube connections
  • Suction Line: 1/4″ diameter
  • Height: Approximately 200mm
  • Weight: Around 11-12 kg
  • Terminal Type: European standard terminal board

Oil Information

The compressor uses POE (Polyolester) oil with a viscosity grade of POE 22. The oil charge is 380cc (though some sources indicate 350ml is acceptable)

www.prokes-auto.com. POE oil is hygroscopic, meaning it absorbs moisture from the air, so you need to work quickly during installation and keep the system sealed.

Electrical Specifications

  • Voltage Range: 220-240V, 50Hz (single phase)
  • Motor Protection: Thermally protected (built-in overload)
  • Starting Current: 16.1A maximum
  • Running Current: Approximately 1.0-1.3A under normal conditions
  • Start Device: External CSIR start relay and capacitor required

Replacement Compressors

Same Refrigerant (R134a) – Direct Replacements

  1. Embraco NEU6210Z – 1/3 HP, R134a, HBP, similar displacement
  2. Embraco NE6187Z – Previous generation, identical specs
  3. Secop/Danfoss SC12G – 1/3 HP, 12.87cc, R134a, HBP/MBP www.ebay.co.uk
  4. Secop/Danfoss TL3G – Universal compressor, 1/3 HP equivalent, R134a www.piecesfrigo.com
  5. GMCC FH2711 – 10.8cc, R134a, HBP application manuals.plus

Alternative Refrigerant Replacements

If you’re considering converting to a different refrigerant:

  1. Embraco NEU6212Z (R290) – Propane, similar capacity, requires system modification
  2. Embraco NLE11MN (R290) – 1/2 HP equivalent, natural refrigerant whufc.pl
  3. Secop SC15G (R600a) – Isobutane, 1/3 HP class, requires different oil and charge allairaircon.co.za
  4. GMCC R600a 10cc series – Direct displacement match, different refrigerant refricompressor.com
  5. Embraco FFI10HBX (R134a) – Alternative R134a option, 1/3 HP www.ebay.com

Important: Switching refrigerants isn’t a simple swap. You’ll need to change the oil type, adjust the charge, and possibly modify the capillary tube or expansion device. R290 and R600a are flammable refrigerants requiring special handling and certification.

Common Applications

You’ll find the NEK6187Z working in:

  • Whirlpool K40 ice machines – This is a very common application www.ascateringsupplies.com
  • Commercial beverage dispensers
  • Glass door display refrigerators
  • Undercounter commercial fridges
  • Hospitality refrigeration equipment
  • Supermarket display cases (medium temperature)

Installation Tips

  1. Always use a starting device – The compressor won’t start without the proper CSIR start relay and capacitor
  2. Fan cooling is recommended – Use a fan with at least 520 m³/h airflow for optimal performance www.kaeltetechnikshop.com
  3. Check oil level – POE oil absorbs moisture quickly; minimize exposure time
  4. Evacuation – Pull a good vacuum (500 microns or better) before charging
  5. Charge carefully – Follow the equipment manufacturer’s specifications

Troubleshooting Common Issues

Compressor won’t start:

  • Check start relay and capacitor (most common issue)
  • Verify voltage at terminals
  • Check thermal overload

High amp draw:

  • Check for restricted capillary tube
  • Verify proper refrigerant charge
  • Inspect condenser for dirt/restriction

Low cooling capacity:

  • Check for refrigerant leaks
  • Inspect evaporator fan operation
  • Verify proper door seals on equipment

Where to Buy

These compressors are available through:

  • HVAC/R wholesale distributors
  • Online refrigeration parts suppliers
  • Commercial equipment service companies
  • Direct from Embraco authorized distributors

Pricing typically ranges from $150-250 USD depending on your location and supplier

hvacspareparts.com.

Warranty and Support

Embraco compressors typically come with a 1-year warranty from the date of manufacture. Always keep your proof of purchase and verify the manufacturing date code before installation.


Focus Keyphrase

Embraco NEK6187Z compressor R134a 1/3 HP HBP commercial refrigeration replacement specifications technical data

SEO Title

Embraco NEK6187Z Compressor | 1/3 HP R134a HBP | Full Specs & Replacements | MBSM.pro

Meta Description

Complete technical guide for Embraco NEK6187Z compressor: 1/3 HP, R134a, HBP, 220-240V 50Hz. Cooling capacity, COP values, replacement options, installation tips. Commercial refrigeration specs.

Slug

embraco-nek6187z-compressor-r134a-1-3-hp-hbp-specifications-replacements

Tags

Embraco NEK6187Z, R134a compressor, 1/3 HP compressor, HBP compressor, commercial refrigeration, CSIR motor, POE oil, NEK6187Z replacement, Secop SC12G, Danfoss compressor, GMCC compressor, R290 compressor, R600a replacement, beverage cooler compressor, ice machine compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, NEK6187Z-A, NE6187Z, NEU6210Z, NEU6212Z, TL3G, SC12GX, compressor replacement R134a, HBP refrigeration, commercial fridge compressor

Excerpt (First 55 words)

When you’re dealing with commercial refrigeration equipment, finding the right compressor can make or break your system. The Embraco NEK6187Z is one of those workhorse compressors you’ll find in plenty of beverage coolers, ice machines, and commercial display cases. Let’s dive into what makes this compressor tick.

Embraco NEK6187Z compressor R134a 1/3 HP HBP commercial refrigeration replacement specifications technical data mbsmpro
1/3 HP Compressor, beverage cooler compressor, commercial refrigeration, compressor replacement R134a, CSIR motor, Danfoss compressor, Embraco NEK6187Z, GMCC compressor, HBP compressor, HBP refrigeration, ice machine compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NE6187Z, NEK6187Z replacement, NEK6187Z-A, NEU6210Z, NEU6212Z, POE oil, R134a compressor, R290 compressor, R600a replacement, SC12GX, Secop SC12G, TL3G



Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro

Mbsmpro.com, Compressor, Danfoss, SLV15CNK, 15.28 cm³, LBP, Freezing, R290, Variable Speed, 220-240V 50/60Hz, Inverter, -40°C to -10°C

Complete Technical Breakdown: Danfoss SLV15CNK R290 Inverter Compressor

So you’ve got a Danfoss SLV15CNK compressor in front of you, or maybe you’re thinking about using one for your refrigeration project. Either way, you’re looking at a pretty sophisticated piece of kit. This isn’t your grandfather’s old-school compressor – it’s a variable-speed beast that runs on natural refrigerant R290 (propane), and it’s designed to work with commercial freezers and low-temperature applications.

What makes this compressor stand out is its inverter technology. Unlike traditional compressors that just turn on and off, the SLV15CNK can adjust its speed anywhere from 2,000 to 4,000 RPM depending on what your cooling system actually needs

www.secop.com. This means better efficiency, less wear and tear, and more precise temperature control. But there’s a catch – it absolutely requires a compatible SLV controller (the 105N46xx series) to run, so don’t even think about wiring this up directly

frigopartners.com.

Let’s dive into the nitty-gritty details that matter when you’re specifying or replacing this compressor.

Main Specifications Table

Specification Details
Model SLV15CNK.2 (also referenced as SLV15CNK)
Manufacturer Danfoss / Secop
Part Number 104H8541
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure) only
Domaine (Freezing/Cooling) Freezing / Low Temperature
Cooling wattage at -23°C 437W @ 2000rpm / 553W @ 2500rpm / 652W @ 3000rpm / 858W @ 4000rpm
Cubic feet can this compressor cool? Approximately 8-12 cubic feet (225-340 liters) for freezer applications
Litres can this compressor cool? 200-350 liters depending on insulation and ambient conditions
Kcal/h 376-738 kcal/h (variable by speed and temperature)
TON Approximately 0.12 – 0.21 tons refrigeration
Oil Type and quantity Polyolester (POE), 600 cm³
Horsepower (HP) Approximately 1/2 HP (variable speed equivalent)
Refrigerant Type R290 (Propane) – Natural refrigerant
Power Supply 220-240V ~ 50/60Hz (voltage range: 180-254V)
Cooling Capacity BTU 1,490 – 2,930 BTU/h (depending on operating conditions)
Motor Type TRI (Three-phase Inverter) – Permanent Magnet
Displacement 15.28 cm³
Winding Material Copper windings (all 3 windings: 7.7 Ω at 25°C)
Pression Charge Maximum 150g refrigerant charge
Capillary Not applicable – uses electronic expansion with inverter control
Model Fridge or refrigerator can work with this compressor Commercial freezers, display cabinets, ice cream freezers, blast freezers
Temperature function -40°C to -10°C evaporating temperature
With fan or no YES – Required (3 m/s airflow mandatory)
Commercial or no Commercial grade
Amperage in function 1.01A – 3.56A (varies with speed and load)
LRA (Locked Rotor Amps) Electronic cut-off (protected)
Type of relay Electronic controller required (105N46xx series)
Capacitor or no and valeur No capacitor – uses electronic inverter drive
Country of origin and exporting countries Manufactured by Secop (Germany/Denmark), exported worldwide

Performance at Different Operating Conditions

Here’s where things get interesting. Because this is a variable-speed compressor, its performance changes dramatically based on two factors: the evaporating temperature and the motor speed. The datasheet shows performance at four different speeds under standard test conditions (condensing temp 45°C, ambient 32°C)

www.secop.com.

Efficiency Metrics (COP) Table

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) @ 2500 rpm 393 509 553 645 805 990
Power Consumption (Watts) @ 2500 rpm 327 371 385 414 455 493
COP @ 2500 rpm 1.20 1.37 1.43 1.56 1.77 2.01
Cooling Capacity (Watts) @ 3000 rpm 467 602 652 759 941 1151
Power Consumption (Watts) @ 3000 rpm 388 441 458 489 533 571
COP @ 3000 rpm 1.21 1.37 1.43 1.55 1.77 2.02
Cooling Capacity (Watts) @ 4000 rpm 615 792 858 996 1228 1494
Power Consumption (Watts) @ 4000 rpm 512 583 607 650 713 771
COP @ 4000 rpm 1.20 1.36 1.42 1.53 1.72 1.94

Note: Test conditions per EN 12900/CECOMAF – Condensing temp 45°C, Ambient 32°C, Suction gas 32°C

www.secop.com

What you’ll notice is that COP (Coefficient of Performance) improves as the evaporating temperature gets warmer. At -30°C, you’re looking at a COP around 1.20, but at -10°C, that jumps to over 2.0. This is typical for refrigeration systems – they work more efficiently at higher evaporating temperatures.

Physical Dimensions & Connections

Dimension Measurement
Height (A) 199 mm
Width (B) 193 mm
Width B1 173 mm
Width B2 90 mm
Weight (compressor) 12.0 kg
Weight (electronic unit) 1.4 kg
Suction connector 10.2 mm I.D., 37° angle, Copper with rubber plug
Discharge connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Process connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Connector tolerance ±0.09 mm

Critical Installation Requirements

Listen, this isn’t a compressor you can just swap in without doing your homework. There are some non-negotiable requirements:

  1. Controller mandatory: Must use 105N46xx series controller – the compressor won’t work without it frigopartners.com
  2. Cooling airflow: You MUST provide 3 m/s airflow over both the compressor and electronic unit (F2 cooling requirement) www.secop.com
  3. Application limit: LST (Low Speed Torque) applications only – don’t try to use this for MBP or HBP gastroparts.com
  4. Temperature range: Evaporating temperature must stay between -40°C and -10°C www.secop.com
  5. Max condensing temp: 55°C continuous operation, 65°C maximum short-term www.secop.com
  6. Max winding temp: 125°C continuous, 135°C short-term www.secop.com

Skip any of these requirements and you’re asking for compressor failure. The datasheet is crystal clear about this

www.secop.com.

Replacement Compressor Options

5 Compressor Replacements (Same R290 Refrigerant)

Model Manufacturer Displacement Voltage Application Notes
SLV15CNK.2 Secop/Danfoss 15.28 cm³ 220-240V LBP Same model – direct replacement
SLV18CNK.2 Secop/Danfoss 18.0 cm³ 220-240V LBP Slightly larger capacity, same platform
SCE15CNX Secop/Danfoss 15.28 cm³ 220-240V LBP/MBP Fixed speed alternative, CSCR motor www.prokes-auto.com
SLVE15CN Secop 15.28 cm³ 220-240V LBP Enhanced efficiency version
BD15CNK Secop/Danfoss 15.0 cm³ 220-240V LBP Similar capacity, different mounting

5 Compressor Replacements (Alternative Refrigerants)

Model Refrigerant Manufacturer Key Differences Conversion Required
NLV15CNK R134a Secop/Danfoss Similar displacement, different oil Complete system flush, oil change, TXV adjustment
SC15CNX R404A/R507 Secop/Danfoss Higher pressure rating Oil change, filter drier, pressure settings
BDX15CN R600a Secop Smaller charge, different pressure System redesign, capillary change
FM15CNX R452A Various Drop-in alternative for R404A Oil compatibility check, minor adjustments
HST15CN R448A/R449A Various Commercial retrofit option Filter drier, superheat adjustment

Important: Changing refrigerants is NOT a simple swap. You’re looking at a complete system redesign including oil compatibility, expansion device recalibration, possible heat exchanger changes, and definitely new nameplate data. Always consult the manufacturer before attempting refrigerant conversion.

Real-World Applications

Where do you actually see these compressors in the wild? Based on what we’ve found, the SLV15CNK.2 shows up in:

  • Commercial display cabinets – particularly AHT brand freezers www.vorcz.cz
  • Ice cream freezers – soft serve and hard ice cream displays www.green-cooling-initiative.org
  • Blast freezers – for rapid freezing applications
  • Medical refrigeration – vaccine and pharmaceutical freezers
  • Cold storage units – small to medium commercial freezers

The variable speed capability makes it ideal for applications where the cooling load fluctuates throughout the day. Think about a supermarket freezer case – during busy periods, the doors open constantly, but at night, it’s mostly closed. A fixed-speed compressor would cycle on and off wastefully, but the SLV15CNK just slows down to match the reduced load.

Energy Efficiency Reality Check

Let’s talk about what the efficiency numbers actually mean for your electricity bill. At typical freezer operating conditions (-23.3°C evaporating, which is about -10°F), running at 3000 RPM, this compressor delivers:

  • Cooling capacity: 652W
  • Power draw: 458W
  • COP: 1.43

That COP of 1.43 means for every watt of electricity you put in, you get 1.43 watts of cooling out. Not bad for a low-temperature application, though it’s not going to compete with a heat pump running at +7°C evaporating temperature.

The real energy savings come from the variable speed capability. Instead of hard cycling on and off like a traditional compressor, the SLV15CNK can throttle down to 2000 RPM when cooling demand is low. This saves energy AND reduces wear on the mechanical components. Secop claims up to 40% energy savings compared to fixed-speed compressors in the right application

archive.hydrocarbons21.com.

Common Problems & Troubleshooting

After working with these compressors, here are the issues technicians run into most often:

Problem: Compressor won’t start

  • Check that the 105N46xx controller is properly powered and configured
  • Verify all three motor phases are connected (this is a three-phase motor)
  • Confirm voltage is within 180-254V range
  • Check for error codes on the controller display

Problem: Overheating

  • Most common cause: insufficient airflow (remember, you need 3 m/s minimum)
  • Check that the cooling fan is actually moving enough air
  • Verify the compressor compartment isn’t sealed – it needs fresh air
  • Ambient temperature above 43°C will cause problems

Problem: Poor cooling performance

  • Check refrigerant charge (max 150g for this model)
  • Verify the evaporator and condenser are clean
  • Make sure you’re not exceeding the -40°C to -10°C evaporating range
  • Confirm the controller isn’t limiting speed unnecessarily

Problem: High power consumption

  • Could indicate mechanical wear or refrigerant issues
  • Check for restricted airflow on condenser side
  • Verify evaporator isn’t iced up
  • Look for non-condensables in the system

Maintenance Tips

These compressors are pretty robust, but they’re not maintenance-free:

  1. Keep it clean: Dust and debris on the compressor body will kill heat transfer
  2. Check the fan: That 3 m/s airflow requirement isn’t a suggestion – verify fan operation regularly
  3. Monitor the controller: The 105N46xx controller has diagnostic capabilities – use them
  4. Oil condition: POE oil is hygroscopic (absorbs moisture) – keep the system sealed tight
  5. Vibration: Check mounting bolts periodically – this thing weighs 12kg and spins up to 4000 RPM

The Bottom Line

The Danfoss SLV15CNK.2 is a serious piece of engineering. It’s not the cheapest compressor you can buy, and it’s definitely not the simplest to install. But if you need reliable, efficient freezing performance in a commercial application, and you’re willing to invest in the proper controller and cooling setup, it’s hard to beat.

The fact that it uses R290 (propane) is both a blessing and a challenge. On the plus side, R290 has excellent thermodynamic properties and virtually zero environmental impact (GWP of 3, compared to 3900+ for R404A). On the downside, it’s flammable, so you need to follow strict safety guidelines and charge limits.

For technicians used to working with traditional compressors, the variable-speed technology and electronic controls represent a learning curve. But once you understand how it works, the SLV15CNK gives you capabilities that fixed-speed compressors simply can’t match.


SEO Elements

Focus Keyphrase (191 characters max): Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

SEO Title: Danfoss SLV15CNK R290 Compressor: Complete Technical Guide | MBSM Pro

Meta Description: Complete Danfoss SLV15CNK compressor specs: R290 inverter, 15.28cm³, LBP freezer -40°C to -10°C, 220-240V. Performance tables, replacement options, installation guide.

Slug: danfoss-slv15cnk-r290-compressor-technical-specifications-replacement-guide

Tags: Danfoss SLV15CNK, Secop SLV15CNK.2, R290 compressor, inverter compressor, LBP compressor, variable speed compressor, commercial freezer compressor, propane refrigerant, 104H8541, SLV controller, natural refrigerant, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, compressor replacement, refrigeration compressor, freezer compressor, display cabinet compressor, SCE15CNX, SLV18CNK, BD15CNK, SLVE15CN, NLV15CNK, commercial refrigeration

Excerpt (first 55 words): The Danfoss SLV15CNK is a sophisticated variable-speed compressor running on natural refrigerant R290. Designed for commercial freezing applications from -40°C to -10°C, this 15.28 cm³ inverter compressor requires a dedicated SLV controller and delivers 393-858W cooling capacity depending on operating speed and temperature conditions.

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro