Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems

mbsmgroup2026-02-07_204312-mbsmpro mbsmpro


Focus Keyphrase

Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems

SEO Title

Mbsmpro.com, Compressor, Jiaxipera, TT1113GY, 1/5 hp, Cooling, R600a, 155 W, 0.9 A, 1Ph 220‑240V 50Hz, LBP, RSIR, -30°C to -10°C, Household Refrigerator

Meta Description

Discover the full technical profile of the Jiaxipera TT1113GY compressor. Expert insights on this 1/5 HP R600a LBP unit, including cooling capacity, wiring, and replacement alternatives.

Slug

jiaxipera-tt1113gy-compressor-1-5-hp-r600a-specifications

Tags

Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Jiaxipera TT1113GY, R600a Compressor, 1/5 HP Compressor, HMK95AA, EMX55CLC, TLES8.7KK.3, NLX8.8KK, GLY90AA, TT1114GY, Jiaxipera Replacement, Refrigerator Repair, HVAC Expert

Excerpt

The Jiaxipera TT1113GY is a cornerstone of modern domestic refrigeration, operating as a 1/5 HP Low Back Pressure compressor optimized for R600a refrigerant. This high-efficiency unit is widely used in household refrigerators and freezers, offering a cooling capacity of 155 Watts. This guide covers all essential technical data, electrical characteristics, and professional replacement options.


Technical Specification Table

Feature Detailed Specification
Model TT1113GY
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigeration / Freezing
Cooling wattage at -23.3°C 155 W
Cubic feet can this compressor cool? 12 – 16 cu.ft. (depending on insulation)
Litres can this compressor cool? 300 – 450 Liters
Kcal/h 133 Kcal/h
Oil Type and quantity Mineral / Alkylbenzene (180 ml)
Horsepower (HP) 1/5 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220–240V / 50Hz / 1 Phase
Cooling Capacity BTU 529 BTU/h
Motor Type RSIR (Resistance Start – Inductive Run)
Displacement 8.9 cm³
Winding Material Copper/Aluminum (OEM standard)
Pression Charge Low side (typical 0.5 to 1.5 psi running)
Capillary Recommendation 0.031″ ID (Length varies by cabinet)
Refrigerator Compatibility Whirlpool, Beko, Haier, Bosch, Hisense
Temperature function -35°C to -10°C
With fan or no Static Cooling (No fan required)
Commercial or no Domestic Only
Amperage in function 0.8 A – 1.1 A
Lara (LRA) 6.5 A
Type of relay PTC Starter
Capacitor No (Usually 4µF or 5µF optional for RSCR)
Origin/Export China / Worldwide

Compressor Replacements (Equivalent Performance)

5 Replacements in same gas (R600a)

  1. ACC / Secop: HMK95AA
  2. Embraco: EMX55CLC
  3. Danfoss: TLES8.7KK.3
  4. GMCC: SZ90E1H
  5. Wanbao: HML110YE

5 Replacements in different gas (R134a)

Note: Requires system flush, oil check, and capillary adjustment.

  1. Embraco: EMI 70HER
  2. ZMC: GM70AZ
  3. Tecumseh: THG1365Y
  4. GMCC: SE54E1J
  5. Jiaxipera: N1113KZ

The Engine of Domestic Cooling: An Expert Look at the Jiaxipera TT1113GY

In the world of modern appliances, the transition toward eco-friendly refrigerants has made the Jiaxipera TT1113GY a standard-bearer for efficiency and reliability. As someone who has spent years in the field, diagnosing cooling cycles and performing heart transplants on refrigerators, I can tell you that this 1/5 HP unit is a workhorse designed for longevity—provided it is handled with professional care.

The TT1113GY is specifically engineered for Low Back Pressure (LBP) applications. This means it thrives in environments where it needs to pull heat out of a frozen space and maintain temperatures well below zero. What makes this model stand out in the current market is its optimization for R600a (Isobutane).

Performance Metrics and Thermodynamic Efficiency

Understanding the efficiency of a compressor requires looking at the Coefficient of Performance (COP). The TT1113GY is designed to provide maximum cooling output while minimizing electricity draw. This is vital for modern energy-star ratings.

Efficiency Metrics (COP) Table
| Evaporating Temp (°C) | Cooling Capacity (Watts) | Power Consumption (Watts) | COP (W/W) |
| :— | :— | :— | :— |
| -30 | 108 | 92 | 1.17 |
| -25 | 142 | 105 | 1.35 |
-23.3 (Standard) | 155 | 112 | 1.38 |
| -20 | 185 | 120 | 1.54 |
| -15 | 240 | 135 | 1.77 |
| -10 | 310 | 150 | 2.06 |

Comparison: Jiaxipera TT1113GY vs. Standard R134a Units

When comparing this R600a unit to older R134a compressors like the GM70AZ, there are distinct differences. The R600a molecules are larger, and the compressor runs at a lower discharge pressure. This results in quieter operation and a significant reduction in environmental impact (Global Warming Potential). However, the TT1113GY uses about 40-50% less refrigerant charge by weight than an R134a counterpart, making precise charging critical for field technicians.

Expert Insights: Field Worker Perspective

If you are replacing a compressor, here is what my experience has taught me about the TT1113GY:

  1. Cleanliness is Godliness: Because R600a uses mineral or alkylbenzene oil, moisture is your worst enemy. Always replace the filter drier and use a high-grade vacuum pump.
  2. Capillary Precautions: The TT1113GY has a 8.9cc displacement. If you are retrofitting this into a cabinet that previously held a smaller 7.5cc unit, monitor your frost pattern closely; you may need to adjust the capillary length to prevent liquid slugging back to the compressor.
  3. Startup Reliability: The RSIR motor is simple and effective. If you encounter startup issues, 90% of the time it is a failing PTC relay rather than the windings themselves.

Pro Tip for Longevity

Ensure the condenser coils are free of dust. While the TT1113GY is a “static cooling” unit (often not needing a fan), it relies on convection. In tight kitchen cabinets, heat buildup is the number one killer of these compressors. Giving the unit “room to breathe” will extend its life by years.

Internal Electrical Configuration (RSIR)

codeText

[Overload Protector]
             |
             C (Common)
            / \
           /   \
 (Main)   M     S (Start)
           \   /
            PTC (Relay)
             |
          [Line In]

(This schematic represents the typical PTC/RSIR wiring for the TT1113GY without a run capacitor.)

Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems
1/5 HP Compressor, EMX55CLC, GLY90AA, HMK95AA, Jiaxipera Replacement, Jiaxipera TT1113GY, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NLX8.8KK, R600a compressor, Refrigerator Repair, TLES8.7KK.3, TT1114GY



Mastering the LG KX69LBEG: The Heart of Modern Domestic Refrigeration

Mastering the LG KX69LBEG: The Heart of Modern Domestic Refrigeration mbsmpro

Mbsm.pro, Compressor, KX69LBEG, 1/5 hp, LG Electronics, R134a, 150 W, 1Ph, 220-240V 50Hz, LBP, Reciprocating, -35°C to -10°C, Refrigerator


Technical Specifications Table

Feature Details
Model KX69LBEG
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Deep Cooling
Oil Type and Quantity POE or Mineral (R134a compatible) / approx. 180-220ml
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V / 50Hz / 1PH
Cooling Capacity BTU Approx. 580 – 620 BTU/h
Motor Type RSIR (Resistance Start – Induction Run)
Displacement 6.9 cm³
Winding Material Copper
Pressure Charge (Suction) 0.5 to 1.2 Bar (Depending on application)
Capillary Recommendation 0.031″ or 0.036″ (Length varies by cabinet)
Refrigerator Models LG GR-Series, Domestic Single/Double Door units
Temperature Function -35°C to -10°C
Fan Requirement Static Cooling (No fan required for compressor)
Commercial Use No (Domestic / Light Residential)
Amperage (RLA) 0.9A – 1.1A
LRA (Locked Rotor Amps) 5.5A – 6.0A
Type of Relay PTC Relay
Capacitor Not required (RSIR), optional Start Cap for high torque

Compressor Cross-Reference (Same Gas – R134a)

  1. Danfoss/Secop: TLS7F
  2. Embraco: EMI60HER / NEK1116Z
  3. Tecumseh: THG1365YS
  4. Samsung: SD162
  5. ACC/Sikor: GVY66AA

Compressor Cross-Reference (Alternative Gas – R600a)

  1. LG: MSA69LBEG (R600a version)
  2. Embraco: EMX55CLC
  3. Danfoss: TLES5.7KK.3
  4. Secop: NLE6.0KK
  5. Jiaxipera: T1112GY

Mastering the LG KX69LBEG: The Heart of Modern Domestic Refrigeration

When a refrigerator fails, the culprit is often the compressor—the mechanical heart that pumps life into the cooling cycle. Among the most reliable workhorses found in household units is the LG KX69LBEG. This 1/5 HP reciprocating compressor is engineered specifically for Low Back Pressure (LBP) applications, making it the ideal candidate for freezers and standard kitchen refrigerators that need to maintain consistent sub-zero temperatures.

Performance Dynamics

The KX69LBEG operates on a displacement of 6.9cc. Unlike larger commercial units that rely on high-torque start capacitors, this model utilizes an RSIR motor configuration. This means it is highly efficient for domestic settings where power stability is standard, drawing approximately 150 Watts during its peak cooling phase. Its thermally protected design ensures that even during high-ambient summer temperatures, the internal windings remain shielded from catastrophic failure.

Comparative Analysis: LG vs. The Competition

In the world of 1/5 HP compressors, the KX69LBEG stands out for its low vibration and silent operation. Compared to the Danfoss TLS7F, the LG model often provides a more compact footprint, which is essential for modern “slim-back” refrigerator designs. While the Embraco NEK1116Z might offer a slightly higher BTU output, the LG KX69LBEG is prized for its longevity and “copper-heavy” winding durability.

Engineering Insights and Installation Tips

  • System Cleansing: When replacing a burnt-out KX69LBEG, always flush the condenser and evaporator. Residual acidity from a motor burnout will destroy the new unit.
  • Filter Drier: Never reuse a filter drier. Always install a new 15g or 20g XH-9 molecular sieve drier to handle the R134a refrigerant.
  • Vacuuming: Ensure a vacuum level of at least 500 microns. R134a is highly sensitive to moisture, which can lead to capillary tube waxing and blockage.

Engineer’s Note: If you are substituting this model with an R600a alternative, you MUST change the expansion device (capillary) and the lubricant. Mixing R134a and R600a systems without proper modification is a recipe for system failure.


Focus Keyphrase: LG KX69LBEG Compressor 1/5 HP R134a Technical Specs

SEO Title: Mbsm.pro – LG KX69LBEG Compressor: 1/5 HP, R134a, LBP Technical Guide

Meta Description: Discover the complete technical specifications for the LG KX69LBEG compressor. This 1/5 HP R134a unit is perfect for domestic refrigerators. Learn about its cooling capacity, amperage, and the best 5 replacements for easy repairs.

Slug: lg-kx69lbeg-compressor-1-5hp-r134a-specifications

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, LG, KX69LBEG, 1/5 HP, R134a, LBP, Compressor Replacement, TLS7F, EMI60HER, THG1365YS, SD162, GVY66AA, EMX55CLC, TLES5.7KK, Refrigeration Repair.

Excerpt: The LG KX69LBEG is a high-performance 1/5 HP reciprocating compressor designed for Low Back Pressure (LBP) domestic refrigeration. Operating on R134a refrigerant at 220-240V/50Hz, this thermally protected unit is the standard for LG’s cooling reliability. In this guide, we break down its displacement, amperage, and provide a comprehensive list of equivalent replacement models.

Mastering the LG KX69LBEG: The Heart of Modern Domestic Refrigeration mbsmpro
Mastering the LG KX69LBEG: The Heart of Modern Domestic Refrigeration mbsmpro