SC18CLX.2 compressor 104L2197 Danfoss Secop R404A R507 LBP 220-240V 50Hz specifications replacement

SC18CLX.2 compressor 104L2197 Danfoss Secop R404A R507 LBP 220-240V 50Hz specifications replacement mbsmpro

Mbsmpro.com, Compressor, SC18CLX.2, 3/4 hp, Danfoss Secop, Freezing, R404A/R507, 104L2197, 1Ph 220‑240V 50Hz, LBP, CSIR, −45°C to +10°C, 17.68 cm³, Made in Germany

Technical Specifications

Specification Value
Model SC18CLX.2 (104L2197)
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Freezing
Cooling wattage at -23°C 849 W (EN 12900) / 986 W (ASHRAE LBP)
Cubic feet can this compressor cool Approximately 6-8 cubic feet
Litres can this compressor cool Approximately 170-225 liters
Kcal/h 730 kcal/h (at -10°C evaporating)
TON 0.25 – 0.3 TON
Oil Type and quantity Polyolester (POE), 550 cm³
Horsepower (HP) 3/4 HP (approximately 0.75 HP)
Refrigerant Type R404A / R507
Power Supply 220-240V, 1 Phase, 50Hz
Cooling Capacity BTU 3671 BTU (at -10°F LBP) www.ebay.com
Motor Type CSIR (Capacitor Start Induction Run)
Displacement 17.68 cm³
Winding Material Copper
Pressure Charge Maximum refrigerant charge: 1300g
Capillary Not specified (system dependent)
Model Fridge or refrigerator Commercial freezers, display cabinets, beverage coolers
Temperature function −45°C to +10°C evaporating temperature
With fan or no Fan cooling (F2)
Commercial or no Yes – Commercial refrigeration
Amperage in function 3.13A to 5.26A (depending on evaporating temp)
LRA (Locked Rotor Amps) 23.5A
Type of relay HST (High Starting Torque) required
Capacitor or no and valeur Starting capacitor required (CSIR motor)
Country of origin and exporting countries Germany (Made in Germany) – Exported worldwide

Efficiency Metrics (COP)

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) 595 780 849 995 1245 1532
Power Consumption (Watts) 598 680 708 765 854 949
COP (W/W) 1.00 1.15 1.20 1.30 1.46 1.61

Performance data based on EN 12900 Household standard, 220V 50Hz, fan cooling

blg.ee

ASHRAE LBP Performance Data

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 5 10
Cooling Capacity (Watts) 691 905 986 1156 1447 1783
Power Consumption (Watts) 598 680 708 765 854 949
COP (W/W) 1.16 1.33 1.39 1.51 1.69 1.88

Performance data based on ASHRAE LBP standard, 220V 50Hz, fan cooling

blg.ee

Current Consumption by Temperature

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10
Current (Amps) 3.98 A 4.28 A 4.39 A 4.60 A 4.92 A 5.26 A

5 Compressor Replacements (Same R404A/R507 Refrigerant)

Model Manufacturer HP Displacement Voltage Notes
SC18CLX.2 Secop/Danfoss 3/4 HP 17.68 cm³ 220-240V 50Hz Original equivalent www.mbsm.pro
SC18/18CL Secop/Danfoss 3/4 HP 17.68 cm³ 220-240V 50Hz LBP/MBP version www.prokes-auto.com
SC15CLX.2 Secop/Danfoss 1/2 HP 12.9 cm³ 220-240V 50Hz Slightly lower capacity
SC21CLX.2 Secop/Danfoss 1 HP 21.0 cm³ 220-240V 50Hz Higher capacity alternative
HST Series Various 3/4 HP Similar 220-240V 50Hz High starting torque models

5 Compressor Replacements (Other Refrigerants – Conversion Required)

Model Refrigerant HP Manufacturer Voltage Notes
SC18/18G R134a 3/4 HP Danfoss/Secop 220-240V 50Hz HBP application www.ebay.com
SC18CNX R290 (Propane) 3/4 HP Danfoss 220-240V 50Hz Natural refrigerant assets.danfoss.com
GS21MLX R134a 1 HP Secop 220-240V 50Hz CSCR motor type www.secop.com
SC18GH R134a 3/4 HP Secop 220-240V 50Hz HBP – High Back Pressure www.skh-kaeltetechnik.de
GM80AF R134a 1/4+ HP ZMC 220V 50Hz Household type (different capacity) www.teksogutan.com

Applications

This compressor is ideal for:

  • Commercial freezers and deep freezers
  • Beverage cooling systems and drink dispensers
  • Display cabinets for frozen foods
  • Ice cream cabinets
  • Cold storage rooms (small to medium size)
  • Medical refrigeration (vaccine freezers, laboratory equipment)
  • Transport refrigeration units

Key Features

Robust German engineering – Manufactured in Germany with strict quality control
Versatile refrigerant compatibility – Works with both R404A and R507
Wide temperature range – Operates efficiently from -45°C to +10°C evaporating temperature
High starting torque – HST design ensures reliable starts even under load
Energy efficient – COP up to 1.88 at optimal conditions
Commercial grade – Built for demanding commercial refrigeration applications

Installation Notes

  • Oil compatibility: Uses polyolester (POE) oil – ensure system is clean and compatible
  • Starting components: Requires appropriate starting capacitor and relay (CSIR motor)
  • Refrigerant charge: Maximum 1300g – follow manufacturer specifications
  • Electrical: Ensure proper voltage supply (220-240V 50Hz single phase)
  • Cooling: Requires adequate ventilation and fan cooling (F2 specification)
  • Professional installation: Must be installed by certified refrigeration technicians

SEO Elements

Focus Keyphrase:
SC18CLX.2 compressor 104L2197 Danfoss Secop R404A R507 LBP 220-240V 50Hz specifications replacement

SEO Title:
SC18CLX.2 Compressor 104L2197 | Danfoss Secop R404A/R507 | Complete Specs & Replacements

Meta Description:
SC18CLX.2 (104L2197) Danfoss/Secop compressor specs: 3/4 HP, R404A/R507, LBP, 220-240V 50Hz, 17.68cm³. Performance data, COP values, replacement guides & technical details. Made in Germany.

Slug:
sc18clx-2-compressor-104l2197-danfoss-secop-r404a-r507-specifications

Tags:
SC18CLX.2, 104L2197, Danfoss compressor, Secop compressor, R404A compressor, R507 compressor, LBP compressor, commercial refrigeration, freezer compressor, 220-240V compressor, CSIR motor, Germany compressor, refrigeration compressor, beverage cooler compressor, display cabinet compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, SC18CLX.2 replacement, 104L2197 replacement, SC18/18CL, SC21CLX.2, SC15CLX.2, R404A replacement, R507 replacement


Excerpt (First 55 Words)

The SC18CLX.2 (104L2197) is a professional-grade hermetic reciprocating compressor manufactured by Danfoss/Secop in Germany. Designed for commercial freezing applications, it operates with R404A/R507 refrigerants on 220-240V 50Hz power supply. With 17.68 cm³ displacement and CSIR motor technology, this LBP compressor delivers reliable performance.

SC18CLX.2 compressor 104L2197 Danfoss Secop R404A R507 LBP 220-240V 50Hz specifications replacement mbsmpro
104L2197, 104L2197 replacement, 220-240V compressor, beverage cooler compressor, commercial refrigeration, CSIR motor, Danfoss compressor, display cabinet compressor, freezer compressor, Germany compressor, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R404A compressor, R404A replacement, R507 compressor, refrigeration compressor, SC15CLX.2, SC18/18CL, SC18CLX.2, SC18CLX.2 replacement, SC21CLX.2, Secop compressor



Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro

Mbsmpro.com, Compressor, Danfoss, SLV15CNK, 15.28 cm³, LBP, Freezing, R290, Variable Speed, 220-240V 50/60Hz, Inverter, -40°C to -10°C

Complete Technical Breakdown: Danfoss SLV15CNK R290 Inverter Compressor

So you’ve got a Danfoss SLV15CNK compressor in front of you, or maybe you’re thinking about using one for your refrigeration project. Either way, you’re looking at a pretty sophisticated piece of kit. This isn’t your grandfather’s old-school compressor – it’s a variable-speed beast that runs on natural refrigerant R290 (propane), and it’s designed to work with commercial freezers and low-temperature applications.

What makes this compressor stand out is its inverter technology. Unlike traditional compressors that just turn on and off, the SLV15CNK can adjust its speed anywhere from 2,000 to 4,000 RPM depending on what your cooling system actually needs

www.secop.com. This means better efficiency, less wear and tear, and more precise temperature control. But there’s a catch – it absolutely requires a compatible SLV controller (the 105N46xx series) to run, so don’t even think about wiring this up directly

frigopartners.com.

Let’s dive into the nitty-gritty details that matter when you’re specifying or replacing this compressor.

Main Specifications Table

Specification Details
Model SLV15CNK.2 (also referenced as SLV15CNK)
Manufacturer Danfoss / Secop
Part Number 104H8541
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure) only
Domaine (Freezing/Cooling) Freezing / Low Temperature
Cooling wattage at -23°C 437W @ 2000rpm / 553W @ 2500rpm / 652W @ 3000rpm / 858W @ 4000rpm
Cubic feet can this compressor cool? Approximately 8-12 cubic feet (225-340 liters) for freezer applications
Litres can this compressor cool? 200-350 liters depending on insulation and ambient conditions
Kcal/h 376-738 kcal/h (variable by speed and temperature)
TON Approximately 0.12 – 0.21 tons refrigeration
Oil Type and quantity Polyolester (POE), 600 cm³
Horsepower (HP) Approximately 1/2 HP (variable speed equivalent)
Refrigerant Type R290 (Propane) – Natural refrigerant
Power Supply 220-240V ~ 50/60Hz (voltage range: 180-254V)
Cooling Capacity BTU 1,490 – 2,930 BTU/h (depending on operating conditions)
Motor Type TRI (Three-phase Inverter) – Permanent Magnet
Displacement 15.28 cm³
Winding Material Copper windings (all 3 windings: 7.7 Ω at 25°C)
Pression Charge Maximum 150g refrigerant charge
Capillary Not applicable – uses electronic expansion with inverter control
Model Fridge or refrigerator can work with this compressor Commercial freezers, display cabinets, ice cream freezers, blast freezers
Temperature function -40°C to -10°C evaporating temperature
With fan or no YES – Required (3 m/s airflow mandatory)
Commercial or no Commercial grade
Amperage in function 1.01A – 3.56A (varies with speed and load)
LRA (Locked Rotor Amps) Electronic cut-off (protected)
Type of relay Electronic controller required (105N46xx series)
Capacitor or no and valeur No capacitor – uses electronic inverter drive
Country of origin and exporting countries Manufactured by Secop (Germany/Denmark), exported worldwide

Performance at Different Operating Conditions

Here’s where things get interesting. Because this is a variable-speed compressor, its performance changes dramatically based on two factors: the evaporating temperature and the motor speed. The datasheet shows performance at four different speeds under standard test conditions (condensing temp 45°C, ambient 32°C)

www.secop.com.

Efficiency Metrics (COP) Table

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) @ 2500 rpm 393 509 553 645 805 990
Power Consumption (Watts) @ 2500 rpm 327 371 385 414 455 493
COP @ 2500 rpm 1.20 1.37 1.43 1.56 1.77 2.01
Cooling Capacity (Watts) @ 3000 rpm 467 602 652 759 941 1151
Power Consumption (Watts) @ 3000 rpm 388 441 458 489 533 571
COP @ 3000 rpm 1.21 1.37 1.43 1.55 1.77 2.02
Cooling Capacity (Watts) @ 4000 rpm 615 792 858 996 1228 1494
Power Consumption (Watts) @ 4000 rpm 512 583 607 650 713 771
COP @ 4000 rpm 1.20 1.36 1.42 1.53 1.72 1.94

Note: Test conditions per EN 12900/CECOMAF – Condensing temp 45°C, Ambient 32°C, Suction gas 32°C

www.secop.com

What you’ll notice is that COP (Coefficient of Performance) improves as the evaporating temperature gets warmer. At -30°C, you’re looking at a COP around 1.20, but at -10°C, that jumps to over 2.0. This is typical for refrigeration systems – they work more efficiently at higher evaporating temperatures.

Physical Dimensions & Connections

Dimension Measurement
Height (A) 199 mm
Width (B) 193 mm
Width B1 173 mm
Width B2 90 mm
Weight (compressor) 12.0 kg
Weight (electronic unit) 1.4 kg
Suction connector 10.2 mm I.D., 37° angle, Copper with rubber plug
Discharge connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Process connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Connector tolerance ±0.09 mm

Critical Installation Requirements

Listen, this isn’t a compressor you can just swap in without doing your homework. There are some non-negotiable requirements:

  1. Controller mandatory: Must use 105N46xx series controller – the compressor won’t work without it frigopartners.com
  2. Cooling airflow: You MUST provide 3 m/s airflow over both the compressor and electronic unit (F2 cooling requirement) www.secop.com
  3. Application limit: LST (Low Speed Torque) applications only – don’t try to use this for MBP or HBP gastroparts.com
  4. Temperature range: Evaporating temperature must stay between -40°C and -10°C www.secop.com
  5. Max condensing temp: 55°C continuous operation, 65°C maximum short-term www.secop.com
  6. Max winding temp: 125°C continuous, 135°C short-term www.secop.com

Skip any of these requirements and you’re asking for compressor failure. The datasheet is crystal clear about this

www.secop.com.

Replacement Compressor Options

5 Compressor Replacements (Same R290 Refrigerant)

Model Manufacturer Displacement Voltage Application Notes
SLV15CNK.2 Secop/Danfoss 15.28 cm³ 220-240V LBP Same model – direct replacement
SLV18CNK.2 Secop/Danfoss 18.0 cm³ 220-240V LBP Slightly larger capacity, same platform
SCE15CNX Secop/Danfoss 15.28 cm³ 220-240V LBP/MBP Fixed speed alternative, CSCR motor www.prokes-auto.com
SLVE15CN Secop 15.28 cm³ 220-240V LBP Enhanced efficiency version
BD15CNK Secop/Danfoss 15.0 cm³ 220-240V LBP Similar capacity, different mounting

5 Compressor Replacements (Alternative Refrigerants)

Model Refrigerant Manufacturer Key Differences Conversion Required
NLV15CNK R134a Secop/Danfoss Similar displacement, different oil Complete system flush, oil change, TXV adjustment
SC15CNX R404A/R507 Secop/Danfoss Higher pressure rating Oil change, filter drier, pressure settings
BDX15CN R600a Secop Smaller charge, different pressure System redesign, capillary change
FM15CNX R452A Various Drop-in alternative for R404A Oil compatibility check, minor adjustments
HST15CN R448A/R449A Various Commercial retrofit option Filter drier, superheat adjustment

Important: Changing refrigerants is NOT a simple swap. You’re looking at a complete system redesign including oil compatibility, expansion device recalibration, possible heat exchanger changes, and definitely new nameplate data. Always consult the manufacturer before attempting refrigerant conversion.

Real-World Applications

Where do you actually see these compressors in the wild? Based on what we’ve found, the SLV15CNK.2 shows up in:

  • Commercial display cabinets – particularly AHT brand freezers www.vorcz.cz
  • Ice cream freezers – soft serve and hard ice cream displays www.green-cooling-initiative.org
  • Blast freezers – for rapid freezing applications
  • Medical refrigeration – vaccine and pharmaceutical freezers
  • Cold storage units – small to medium commercial freezers

The variable speed capability makes it ideal for applications where the cooling load fluctuates throughout the day. Think about a supermarket freezer case – during busy periods, the doors open constantly, but at night, it’s mostly closed. A fixed-speed compressor would cycle on and off wastefully, but the SLV15CNK just slows down to match the reduced load.

Energy Efficiency Reality Check

Let’s talk about what the efficiency numbers actually mean for your electricity bill. At typical freezer operating conditions (-23.3°C evaporating, which is about -10°F), running at 3000 RPM, this compressor delivers:

  • Cooling capacity: 652W
  • Power draw: 458W
  • COP: 1.43

That COP of 1.43 means for every watt of electricity you put in, you get 1.43 watts of cooling out. Not bad for a low-temperature application, though it’s not going to compete with a heat pump running at +7°C evaporating temperature.

The real energy savings come from the variable speed capability. Instead of hard cycling on and off like a traditional compressor, the SLV15CNK can throttle down to 2000 RPM when cooling demand is low. This saves energy AND reduces wear on the mechanical components. Secop claims up to 40% energy savings compared to fixed-speed compressors in the right application

archive.hydrocarbons21.com.

Common Problems & Troubleshooting

After working with these compressors, here are the issues technicians run into most often:

Problem: Compressor won’t start

  • Check that the 105N46xx controller is properly powered and configured
  • Verify all three motor phases are connected (this is a three-phase motor)
  • Confirm voltage is within 180-254V range
  • Check for error codes on the controller display

Problem: Overheating

  • Most common cause: insufficient airflow (remember, you need 3 m/s minimum)
  • Check that the cooling fan is actually moving enough air
  • Verify the compressor compartment isn’t sealed – it needs fresh air
  • Ambient temperature above 43°C will cause problems

Problem: Poor cooling performance

  • Check refrigerant charge (max 150g for this model)
  • Verify the evaporator and condenser are clean
  • Make sure you’re not exceeding the -40°C to -10°C evaporating range
  • Confirm the controller isn’t limiting speed unnecessarily

Problem: High power consumption

  • Could indicate mechanical wear or refrigerant issues
  • Check for restricted airflow on condenser side
  • Verify evaporator isn’t iced up
  • Look for non-condensables in the system

Maintenance Tips

These compressors are pretty robust, but they’re not maintenance-free:

  1. Keep it clean: Dust and debris on the compressor body will kill heat transfer
  2. Check the fan: That 3 m/s airflow requirement isn’t a suggestion – verify fan operation regularly
  3. Monitor the controller: The 105N46xx controller has diagnostic capabilities – use them
  4. Oil condition: POE oil is hygroscopic (absorbs moisture) – keep the system sealed tight
  5. Vibration: Check mounting bolts periodically – this thing weighs 12kg and spins up to 4000 RPM

The Bottom Line

The Danfoss SLV15CNK.2 is a serious piece of engineering. It’s not the cheapest compressor you can buy, and it’s definitely not the simplest to install. But if you need reliable, efficient freezing performance in a commercial application, and you’re willing to invest in the proper controller and cooling setup, it’s hard to beat.

The fact that it uses R290 (propane) is both a blessing and a challenge. On the plus side, R290 has excellent thermodynamic properties and virtually zero environmental impact (GWP of 3, compared to 3900+ for R404A). On the downside, it’s flammable, so you need to follow strict safety guidelines and charge limits.

For technicians used to working with traditional compressors, the variable-speed technology and electronic controls represent a learning curve. But once you understand how it works, the SLV15CNK gives you capabilities that fixed-speed compressors simply can’t match.


SEO Elements

Focus Keyphrase (191 characters max): Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

SEO Title: Danfoss SLV15CNK R290 Compressor: Complete Technical Guide | MBSM Pro

Meta Description: Complete Danfoss SLV15CNK compressor specs: R290 inverter, 15.28cm³, LBP freezer -40°C to -10°C, 220-240V. Performance tables, replacement options, installation guide.

Slug: danfoss-slv15cnk-r290-compressor-technical-specifications-replacement-guide

Tags: Danfoss SLV15CNK, Secop SLV15CNK.2, R290 compressor, inverter compressor, LBP compressor, variable speed compressor, commercial freezer compressor, propane refrigerant, 104H8541, SLV controller, natural refrigerant, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, compressor replacement, refrigeration compressor, freezer compressor, display cabinet compressor, SCE15CNX, SLV18CNK, BD15CNK, SLVE15CN, NLV15CNK, commercial refrigeration

Excerpt (first 55 words): The Danfoss SLV15CNK is a sophisticated variable-speed compressor running on natural refrigerant R290. Designed for commercial freezing applications from -40°C to -10°C, this 15.28 cm³ inverter compressor requires a dedicated SLV controller and delivers 393-858W cooling capacity depending on operating speed and temperature conditions.

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro