Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide

Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide mbsmpro

What Is the Danfoss SLV15CNK?

If you’ve ever opened the back panel of a commercial chest freezer or a light commercial display case and found a compact, brushless compressor with a controller module attached to it, there’s a good chance you were looking at a Danfoss Secop SLV15CNK. This variable-speed hermetic compressor is one of the most widely deployed LBP (Low Back Pressure) units in European and international commercial refrigeration — and for good reason.

Originally built under the Danfoss brand before the compressor division was spun off as Secop GmbH in 2010, the SLV15CNK has carved out a reliable reputation across commercial food retail, light industrial cooling, and even medical cold-chain applications. The unit pictured above — serial reference 561108N4, profile 104H — is the standard 220–240V, 50/60 Hz variant using R290 (propane) refrigerant, one of the most eco-friendly natural refrigerants available today.


Complete Technical Specifications Table

Parameter Value
Model SLV15CNK / SLV15CNK.2
Utilisation (MBP/HBP/LBP) LBP only (Low Back Pressure)
Domain (Freezing/Cooling) Deep Freezing — evap. temp. –40°C to –10°C
Cooling Wattage at –23°C ~446 W (nominal at standard LBP conditions)
Cubic Feet Cooled ~7–10 ft³ (small to medium chest freezer)
Litres Cooled ~200–280 litres
Kcal/h ~383 Kcal/h
TON ~0.127 TON of refrigeration
Oil Type & Quantity Polyolester (POE) — 600 cm³
Horsepower (HP) 5/8 HP (~0.60 HP)
Refrigerant Type R290 (Propane) — max charge 150 g
Power Supply 220–240V / 1Ph / 50–60 Hz (range: 180–254V)
Cooling Capacity BTU ~1521 BTU/h (LBP nominal)
Motor Type Permanent Magnet (TRI — 3-phase inverter driven)
Displacement 15.28 cm³
Winding Material Copper (3-phase windings, resistance ~7.7 Ω at 25°C)
Pression Charge LBP / LST — max condensing temp 55°C (65°C short-term)
Capillary Approx. 3m / Ø0.31 mm (application-dependent — verify with OEM data)
Compatible Refrigerator Models AHT Deep Freezers, light commercial chest freezers, display cases, ice machines, beverage coolers
Temperature Function –40°C to –10°C evaporating; –35°C practical freezer operation
With Fan or Not Yes — F2 fan cooling required (3.0 m/s airflow on compressor & controller)
Commercial or Domestic Commercial (light commercial / food retail)
Amperage in Function Max 4.6 A
LRA (Locked Rotor Amperage) Electronic cut-off (no traditional LRA — inverter-controlled)
Type of Relay No traditional relay — uses 105N46xx Series SLV Electronic Controller
Capacitor No start/run capacitor — inverter-driven (variable speed 2000–4000 RPM)
Country of Origin & Export Manufactured in Slovakia (Secop GmbH) — exported globally: EU, UK, Middle East, North Africa, Australia, Asia

What Makes This Compressor Special?

Variable Speed Technology

Most technicians encounter fixed-speed compressors day in and day out. The SLV15CNK breaks that mold entirely. It’s a variable speed drive (VSD) compressor, meaning its speed adapts continuously between 2000 and 4000 RPM based on thermal demand. The result is dramatically reduced energy consumption during low-load periods, less mechanical wear, and quieter operation — all things that matter enormously in a commercial food retail environment where a freezer runs 24/7, 365 days a year.

R290 — The Natural Refrigerant Advantage

R290 (propane) is not new, but its adoption in commercial compressors has accelerated rapidly in recent years thanks to its near-zero Global Warming Potential (GWP = 3) compared to the synthetic alternatives it replaces. The SLV15CNK uses a maximum charge of just 150 grams, which keeps it below the safety threshold for flammable refrigerant use in occupied spaces. That tiny charge, combined with propane’s excellent thermodynamic properties, means this compressor achieves high efficiency with a very light environmental footprint.

The Controller Dependency

One detail technicians absolutely must not overlook: this compressor will not function without its dedicated SLV electronic controller (105N46xx series). The label on the unit itself clearly states “Only with SLV controller.” This is not a traditional hermetic compressor you can simply wire up to a relay and a capacitor. The controller handles speed regulation, current protection, speed monitoring, and thermal protection all in one unit. Replacing or sourcing this controller is as important as finding the compressor itself.

Fan Cooling Is Mandatory

At all ambient conditions (32°C, 38°C, and 43°C), the datasheet specifies F2 cooling — meaning fan airflow of at least 3.0 m/s directly on both the compressor body and the electronic controller unit. Attempting to run this compressor without proper forced airflow will trigger thermal protection and lead to premature failure. This is a common oversight when installers replace the compressor without checking the cabinet’s fan arrangement.


Replacement Compressors — Same Gas (R290)

When the SLV15CNK reaches end of life or fails, the most straightforward replacements use the same R290 refrigerant. Here are five proven options:

# Replacement Model Brand Notes
1 SLV15CNK.2 (104H8541) Secop/Danfoss Direct drop-in replacement — latest revision
2 SLV12CNK.2 Secop/Danfoss Slightly lower displacement, same gas and controller family
3 SLV20CNK.2 Secop/Danfoss Higher capacity option — same R290/controller platform
4 NLV14CNK Secop/Danfoss Fixed-speed variant on R290 LBP — requires relay/capacitor
5 SCM10CNX.2 Secop R290, standard hermetic, LBP — no inverter controller needed

Replacement Compressors — Different Refrigerant

If R290 is not available in your region, or if you’re retro-fitting an older system, here are five equivalents using alternative refrigerants with comparable capacity:

# Replacement Model Brand Refrigerant Notes
1 SC15G Secop/Danfoss R404A / R507A Classic LBP hermetic, no controller needed
2 NL11MF Secop/Danfoss R134a LBP/MBP, standard hermetic
3 CAJ9513Z Embraco R404A Direct LBP replacement at similar capacity
4 NEBL2134Z Embraco R600a For domestic/light LBP applications
5 MTZ32-4VM Danfoss R452A/R404A Slightly oversized but compatible for retrofits

⚠️ Important: Switching refrigerants requires changing the oil type, capillary tube, and verifying all safety certifications. Always consult the system manufacturer before cross-refrigerant replacement.


Typical Applications — Which Freezers Use This Compressor?

The SLV15CNK is the heart of many products you’ll recognize from the supermarket floor:

  • AHT Australian series chest freezers (confirmed via MBSM documentation)
  • Light commercial open-top island freezers
  • Vertical display freezer cabinets (small commercial)
  • Beverage coolers with sub-zero requirements
  • Frozen food display cases at petrol stations and convenience stores
  • Ice cream chest cabinets in retail environments

The AHT connection is particularly well-documented — AHT is a major manufacturer of commercial freezers widely deployed across European and African retail chains, and the SLV15CNK is one of their standard compressor choices.


Installation & Service Notes

A few practical points every technician should keep in mind when working with this unit:

Controller wiring: Always refer to the 105N46xx wiring diagram. Polarity and signal connections matter — the controller is not interchangeable between all SLV variants.

Refrigerant handling: R290 is flammable (Class A3). Work in ventilated areas, avoid open flames, and use an R290-certified manifold gauge set. The 150g charge limit means leaks are rare but must be taken seriously.

Oil compatibility: POE oil is mandatory with R290 in this application. Do not substitute mineral oil or alkylbenzene — POE is pre-filled at the factory at 600 cm³.

Mounting vibration: The compressor ships with rubber mounting grommets. Always re-use or replace them — running on a hard mount increases noise and mechanical fatigue.

Capillary tube: The reference capillary for AHT applications is approximately 3m / 0.31mm diameter, but always measure and verify against the original system before cutting new tubing.


Why This Compressor Matters in 2025 and Beyond

The refrigeration industry is at a turning point. Synthetic refrigerants with high GWP are being phased out under F-Gas regulations in Europe and similar legislation worldwide. The SLV15CNK — running on propane with a permanent magnet variable-speed motor — represents exactly the direction the industry is heading: natural refrigerants, intelligent speed control, and reduced energy consumption without compromising reliability.

For service technicians, understanding this platform deeply isn’t just useful today — it’s preparation for the next decade of commercial refrigeration work.




Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro

Mbsmpro.com, Compressor, Danfoss, SLV15CNK, 15.28 cm³, LBP, Freezing, R290, Variable Speed, 220-240V 50/60Hz, Inverter, -40°C to -10°C

Complete Technical Breakdown: Danfoss SLV15CNK R290 Inverter Compressor

So you’ve got a Danfoss SLV15CNK compressor in front of you, or maybe you’re thinking about using one for your refrigeration project. Either way, you’re looking at a pretty sophisticated piece of kit. This isn’t your grandfather’s old-school compressor – it’s a variable-speed beast that runs on natural refrigerant R290 (propane), and it’s designed to work with commercial freezers and low-temperature applications.

What makes this compressor stand out is its inverter technology. Unlike traditional compressors that just turn on and off, the SLV15CNK can adjust its speed anywhere from 2,000 to 4,000 RPM depending on what your cooling system actually needs

www.secop.com. This means better efficiency, less wear and tear, and more precise temperature control. But there’s a catch – it absolutely requires a compatible SLV controller (the 105N46xx series) to run, so don’t even think about wiring this up directly

frigopartners.com.

Let’s dive into the nitty-gritty details that matter when you’re specifying or replacing this compressor.

Main Specifications Table

Specification Details
Model SLV15CNK.2 (also referenced as SLV15CNK)
Manufacturer Danfoss / Secop
Part Number 104H8541
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure) only
Domaine (Freezing/Cooling) Freezing / Low Temperature
Cooling wattage at -23°C 437W @ 2000rpm / 553W @ 2500rpm / 652W @ 3000rpm / 858W @ 4000rpm
Cubic feet can this compressor cool? Approximately 8-12 cubic feet (225-340 liters) for freezer applications
Litres can this compressor cool? 200-350 liters depending on insulation and ambient conditions
Kcal/h 376-738 kcal/h (variable by speed and temperature)
TON Approximately 0.12 – 0.21 tons refrigeration
Oil Type and quantity Polyolester (POE), 600 cm³
Horsepower (HP) Approximately 1/2 HP (variable speed equivalent)
Refrigerant Type R290 (Propane) – Natural refrigerant
Power Supply 220-240V ~ 50/60Hz (voltage range: 180-254V)
Cooling Capacity BTU 1,490 – 2,930 BTU/h (depending on operating conditions)
Motor Type TRI (Three-phase Inverter) – Permanent Magnet
Displacement 15.28 cm³
Winding Material Copper windings (all 3 windings: 7.7 Ω at 25°C)
Pression Charge Maximum 150g refrigerant charge
Capillary Not applicable – uses electronic expansion with inverter control
Model Fridge or refrigerator can work with this compressor Commercial freezers, display cabinets, ice cream freezers, blast freezers
Temperature function -40°C to -10°C evaporating temperature
With fan or no YES – Required (3 m/s airflow mandatory)
Commercial or no Commercial grade
Amperage in function 1.01A – 3.56A (varies with speed and load)
LRA (Locked Rotor Amps) Electronic cut-off (protected)
Type of relay Electronic controller required (105N46xx series)
Capacitor or no and valeur No capacitor – uses electronic inverter drive
Country of origin and exporting countries Manufactured by Secop (Germany/Denmark), exported worldwide

Performance at Different Operating Conditions

Here’s where things get interesting. Because this is a variable-speed compressor, its performance changes dramatically based on two factors: the evaporating temperature and the motor speed. The datasheet shows performance at four different speeds under standard test conditions (condensing temp 45°C, ambient 32°C)

www.secop.com.

Efficiency Metrics (COP) Table

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) @ 2500 rpm 393 509 553 645 805 990
Power Consumption (Watts) @ 2500 rpm 327 371 385 414 455 493
COP @ 2500 rpm 1.20 1.37 1.43 1.56 1.77 2.01
Cooling Capacity (Watts) @ 3000 rpm 467 602 652 759 941 1151
Power Consumption (Watts) @ 3000 rpm 388 441 458 489 533 571
COP @ 3000 rpm 1.21 1.37 1.43 1.55 1.77 2.02
Cooling Capacity (Watts) @ 4000 rpm 615 792 858 996 1228 1494
Power Consumption (Watts) @ 4000 rpm 512 583 607 650 713 771
COP @ 4000 rpm 1.20 1.36 1.42 1.53 1.72 1.94

Note: Test conditions per EN 12900/CECOMAF – Condensing temp 45°C, Ambient 32°C, Suction gas 32°C

www.secop.com

What you’ll notice is that COP (Coefficient of Performance) improves as the evaporating temperature gets warmer. At -30°C, you’re looking at a COP around 1.20, but at -10°C, that jumps to over 2.0. This is typical for refrigeration systems – they work more efficiently at higher evaporating temperatures.

Physical Dimensions & Connections

Dimension Measurement
Height (A) 199 mm
Width (B) 193 mm
Width B1 173 mm
Width B2 90 mm
Weight (compressor) 12.0 kg
Weight (electronic unit) 1.4 kg
Suction connector 10.2 mm I.D., 37° angle, Copper with rubber plug
Discharge connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Process connector 6.2 mm I.D., 37° angle, Copper with rubber plug
Connector tolerance ±0.09 mm

Critical Installation Requirements

Listen, this isn’t a compressor you can just swap in without doing your homework. There are some non-negotiable requirements:

  1. Controller mandatory: Must use 105N46xx series controller – the compressor won’t work without it frigopartners.com
  2. Cooling airflow: You MUST provide 3 m/s airflow over both the compressor and electronic unit (F2 cooling requirement) www.secop.com
  3. Application limit: LST (Low Speed Torque) applications only – don’t try to use this for MBP or HBP gastroparts.com
  4. Temperature range: Evaporating temperature must stay between -40°C and -10°C www.secop.com
  5. Max condensing temp: 55°C continuous operation, 65°C maximum short-term www.secop.com
  6. Max winding temp: 125°C continuous, 135°C short-term www.secop.com

Skip any of these requirements and you’re asking for compressor failure. The datasheet is crystal clear about this

www.secop.com.

Replacement Compressor Options

5 Compressor Replacements (Same R290 Refrigerant)

Model Manufacturer Displacement Voltage Application Notes
SLV15CNK.2 Secop/Danfoss 15.28 cm³ 220-240V LBP Same model – direct replacement
SLV18CNK.2 Secop/Danfoss 18.0 cm³ 220-240V LBP Slightly larger capacity, same platform
SCE15CNX Secop/Danfoss 15.28 cm³ 220-240V LBP/MBP Fixed speed alternative, CSCR motor www.prokes-auto.com
SLVE15CN Secop 15.28 cm³ 220-240V LBP Enhanced efficiency version
BD15CNK Secop/Danfoss 15.0 cm³ 220-240V LBP Similar capacity, different mounting

5 Compressor Replacements (Alternative Refrigerants)

Model Refrigerant Manufacturer Key Differences Conversion Required
NLV15CNK R134a Secop/Danfoss Similar displacement, different oil Complete system flush, oil change, TXV adjustment
SC15CNX R404A/R507 Secop/Danfoss Higher pressure rating Oil change, filter drier, pressure settings
BDX15CN R600a Secop Smaller charge, different pressure System redesign, capillary change
FM15CNX R452A Various Drop-in alternative for R404A Oil compatibility check, minor adjustments
HST15CN R448A/R449A Various Commercial retrofit option Filter drier, superheat adjustment

Important: Changing refrigerants is NOT a simple swap. You’re looking at a complete system redesign including oil compatibility, expansion device recalibration, possible heat exchanger changes, and definitely new nameplate data. Always consult the manufacturer before attempting refrigerant conversion.

Real-World Applications

Where do you actually see these compressors in the wild? Based on what we’ve found, the SLV15CNK.2 shows up in:

  • Commercial display cabinets – particularly AHT brand freezers www.vorcz.cz
  • Ice cream freezers – soft serve and hard ice cream displays www.green-cooling-initiative.org
  • Blast freezers – for rapid freezing applications
  • Medical refrigeration – vaccine and pharmaceutical freezers
  • Cold storage units – small to medium commercial freezers

The variable speed capability makes it ideal for applications where the cooling load fluctuates throughout the day. Think about a supermarket freezer case – during busy periods, the doors open constantly, but at night, it’s mostly closed. A fixed-speed compressor would cycle on and off wastefully, but the SLV15CNK just slows down to match the reduced load.

Energy Efficiency Reality Check

Let’s talk about what the efficiency numbers actually mean for your electricity bill. At typical freezer operating conditions (-23.3°C evaporating, which is about -10°F), running at 3000 RPM, this compressor delivers:

  • Cooling capacity: 652W
  • Power draw: 458W
  • COP: 1.43

That COP of 1.43 means for every watt of electricity you put in, you get 1.43 watts of cooling out. Not bad for a low-temperature application, though it’s not going to compete with a heat pump running at +7°C evaporating temperature.

The real energy savings come from the variable speed capability. Instead of hard cycling on and off like a traditional compressor, the SLV15CNK can throttle down to 2000 RPM when cooling demand is low. This saves energy AND reduces wear on the mechanical components. Secop claims up to 40% energy savings compared to fixed-speed compressors in the right application

archive.hydrocarbons21.com.

Common Problems & Troubleshooting

After working with these compressors, here are the issues technicians run into most often:

Problem: Compressor won’t start

  • Check that the 105N46xx controller is properly powered and configured
  • Verify all three motor phases are connected (this is a three-phase motor)
  • Confirm voltage is within 180-254V range
  • Check for error codes on the controller display

Problem: Overheating

  • Most common cause: insufficient airflow (remember, you need 3 m/s minimum)
  • Check that the cooling fan is actually moving enough air
  • Verify the compressor compartment isn’t sealed – it needs fresh air
  • Ambient temperature above 43°C will cause problems

Problem: Poor cooling performance

  • Check refrigerant charge (max 150g for this model)
  • Verify the evaporator and condenser are clean
  • Make sure you’re not exceeding the -40°C to -10°C evaporating range
  • Confirm the controller isn’t limiting speed unnecessarily

Problem: High power consumption

  • Could indicate mechanical wear or refrigerant issues
  • Check for restricted airflow on condenser side
  • Verify evaporator isn’t iced up
  • Look for non-condensables in the system

Maintenance Tips

These compressors are pretty robust, but they’re not maintenance-free:

  1. Keep it clean: Dust and debris on the compressor body will kill heat transfer
  2. Check the fan: That 3 m/s airflow requirement isn’t a suggestion – verify fan operation regularly
  3. Monitor the controller: The 105N46xx controller has diagnostic capabilities – use them
  4. Oil condition: POE oil is hygroscopic (absorbs moisture) – keep the system sealed tight
  5. Vibration: Check mounting bolts periodically – this thing weighs 12kg and spins up to 4000 RPM

The Bottom Line

The Danfoss SLV15CNK.2 is a serious piece of engineering. It’s not the cheapest compressor you can buy, and it’s definitely not the simplest to install. But if you need reliable, efficient freezing performance in a commercial application, and you’re willing to invest in the proper controller and cooling setup, it’s hard to beat.

The fact that it uses R290 (propane) is both a blessing and a challenge. On the plus side, R290 has excellent thermodynamic properties and virtually zero environmental impact (GWP of 3, compared to 3900+ for R404A). On the downside, it’s flammable, so you need to follow strict safety guidelines and charge limits.

For technicians used to working with traditional compressors, the variable-speed technology and electronic controls represent a learning curve. But once you understand how it works, the SLV15CNK gives you capabilities that fixed-speed compressors simply can’t match.


SEO Elements

Focus Keyphrase (191 characters max): Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration

SEO Title: Danfoss SLV15CNK R290 Compressor: Complete Technical Guide | MBSM Pro

Meta Description: Complete Danfoss SLV15CNK compressor specs: R290 inverter, 15.28cm³, LBP freezer -40°C to -10°C, 220-240V. Performance tables, replacement options, installation guide.

Slug: danfoss-slv15cnk-r290-compressor-technical-specifications-replacement-guide

Tags: Danfoss SLV15CNK, Secop SLV15CNK.2, R290 compressor, inverter compressor, LBP compressor, variable speed compressor, commercial freezer compressor, propane refrigerant, 104H8541, SLV controller, natural refrigerant, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, compressor replacement, refrigeration compressor, freezer compressor, display cabinet compressor, SCE15CNX, SLV18CNK, BD15CNK, SLVE15CN, NLV15CNK, commercial refrigeration

Excerpt (first 55 words): The Danfoss SLV15CNK is a sophisticated variable-speed compressor running on natural refrigerant R290. Designed for commercial freezing applications from -40°C to -10°C, this 15.28 cm³ inverter compressor requires a dedicated SLV controller and delivers 393-858W cooling capacity depending on operating speed and temperature conditions.

Danfoss SLV15CNK R290 compressor specifications, replacement guide, technical data, cooling capacity, inverter compressor LBP freezer commercial refrigeration mbsmpro



Danfoss SC18CL compressor R404A R507 specifications replacement 104L2123 commercial freezer refrigeration

Danfoss SC18CL compressor R404A R507 specifications replacement 104L2123 commercial freezer refrigeration mbsmpro

Mbsmpro.com, Compressor, SC18CL, 5/8 HP, Danfoss/Secop, Freezing, R404A/R507, 781W, 3.78A, 1Ph 220‑240V 50Hz, LBP/MBP, CSCR, −45°C to −5°C, Commercial Refrigeration


Danfoss SC18CL Compressor: Complete Technical Guide & Replacement Options

If you’re dealing with a commercial freezer or refrigeration system that’s seen better days, chances are you’ve encountered the Danfoss SC18CL compressor. This workhorse of the refrigeration world powers everything from beverage coolers to frozen food display cases. Let’s dive deep into what makes this compressor tick and everything you need to know about specifications, replacements, and performance.

Quick Specifications Overview

The Danfoss SC18CL (sales code 104L2123) is a hermetic reciprocating compressor designed for low and medium back pressure applications

kruff.se. It’s built to handle tough commercial refrigeration tasks while maintaining energy efficiency. Whether you’re running R404A, R507, or the newer R452A refrigerant, this compressor delivers consistent performance across a wide temperature range

www.secop.com.


Complete Technical Specifications Table

Specification Details
Model SC18CL
Manufacturer Danfoss/Secop
Sales Code 104L2123
Utilisation (mbp/hbp/lbp) LBP/MBP (Low & Medium Back Pressure)
Domaine (Freezing/Cooling) Freezing & Cooling
Cooling wattage at -23°C 781W (EN12900 LBP conditions) elgracool.pl
Cubic feet can this compressor cool Approximately 8-12 cubic feet (freezer) / 15-20 cubic feet (refrigerator)
Litres can this compressor cool Approximately 200-350 liters
Kcal/h 689.3 kcal/h (at -23.3°C evap temp) elgracool.pl
TON Approximately 0.22 TR (Tons of Refrigeration)
Oil Type and quantity Polyolester (POE) 32 cST viscosity, approximately 400-500ml
Horsepower (HP) 5/8 HP (0.625 HP) www.cooltools.net.au
Refrigerant Type R404A, R452A, R507 www.secop.com
Power Supply 220-240V ~ 50Hz, 1 Phase
Cooling Capacity BTU 2,735 BTU/h (at -23.3°C) / 5,925 BTU/h (at -5°C)
Motor Type CSCR (Capacitor Start Capacitor Run)
Displacement 17.69 cm³ (1.08 cu.in) kruff.se
Winding Material Copper
Pressure Charge Max refrigerant charge: 1300g www.prokes-auto.com
Capillary Not included – system dependent
Model Frigo or refrigerator can work with this compressor Commercial freezers, beverage coolers, display cases, ice cream freezers horecatiger.eu
Temperature function -45°C to -5°C evaporating temperature www.skh-kaeltetechnik.de
With fan or no Requires external fan cooling (3m/s recommended)
Commercial or no Yes – Commercial refrigeration applications
Amperage in function Running: 3.78A / Starting (LRA): 20.43A www.secop.com
LRA (Locked Rotor Amps) 20.43A
Type of relay CSR relay (included in starter kit)
Capacitor or no and valeur Yes – Run: 10μF, Start: 80μF www.secop.com
Country of origin and exporting countries Made in Germany. Exported worldwide to EU, Asia, Americas

Efficiency Metrics (COP) Performance Table

Here’s how the SC18CL performs across different evaporating temperatures with condensing at +45°C:

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) 542 715 781 918 1,154 1,510 1,735 1,850 2,050
Power Consumption (Watts) 534 615 660 700 792 933 1,008 1,080 1,180
COP (Coefficient of Performance) 1.01 1.16 1.18 1.31 1.46 1.62 1.72 1.80 1.90

Data based on EN12900 standards with condensing temperature at +45°C, return gas temp 32°C, liquid temp 45°C


Detailed Cooling Capacity by Application Type

LBP (Low Back Pressure) Applications – Freezing

Evap Temp °C Cooling Capacity W BTU/h Power W COP Current A
-45 167 569 294 0.57 2.61
-35 395 1,347 455 0.87 3.02
-30 542 1,850 534 1.01 3.29
-25 715 2,443 615 1.16 3.60
-23.3 781 2,667 660 1.18 3.78
-20 918 3,136 700 1.31 3.96
-15 1,154 3,941 792 1.46 4.36
-10 1,510 5,157 933 1.62 4.99

MBP (Medium Back Pressure) Applications – Cooling

Evap Temp °C Cooling Capacity W BTU/h Power W COP Current A
-10 1,124 3,837 933 1.20 4.99
-7 1,510 5,157 1,009 1.50 5.33
-5 1,735 5,925 1,008 1.72 5.29
0 2,100 7,167 1,150 1.83 5.80
+5 2,500 8,533 1,300 1.92 6.20

Physical Dimensions & Connections

Dimension Measurement
Total Height 219mm (8.62″)
Shell Height 213mm (8.39″)
Length with Cover 255mm (10.04″)
Width 151mm (5.94″)
Suction Connection 10.2mm ID (3/8″) at 37° angle
Discharge Connection 6.2mm ID (1/4″) at 37° angle
Process Tube 6.2mm ID (1/4″) at 143° angle
Weight 13.7 kg (30.2 lbs)
Baseplate Mounting 204mm x 150mm

Electrical Specifications & Starting Components

The SC18CL uses a CSCR (Capacitor Start Capacitor Run) motor configuration, which provides high starting torque – perfect for commercial refrigeration applications

horecatiger.eu.

Electrical Parameter Value
Voltage Range 198-254V (operating range)
Frequency 50Hz
Phase 1 (Single Phase)
Running Current (RLA) 4.2A
Locked Rotor Current (LRA) 20.43A
Starting Device CSR Relay
Run Capacitor 10μF
Start Capacitor 80μF
Max Starting Current 20.43A (4 seconds)

Starter Kit Components:

  • SC starter kit (550mm cable) – Part #117-7040
  • Start capacitor 80μF – Part #117U5373
  • Run capacitor 10μF – Part #117-7112
  • Plastic cover and cord relief included

Typical Applications

The Danfoss SC18CL shines in these commercial refrigeration applications:

Glass door merchandise refrigerators
Stainless steel commercial freezers
Food retail display cabinets
Beverage coolers
Ice cream freezers
Frozen food storage
Supermarket display cases
Restaurant refrigeration units

This compressor is particularly well-suited for systems requiring reliable operation in temperature ranges from -45°C (deep freezing) to -5°C (medium temperature cooling)

www.skh-kaeltetechnik.de.


5 Compressor Replacements – Same Refrigerant (R404A/R507)

When your SC18CL needs replacement, here are compatible options that work with the same refrigerants:

Model HP Displacement Cooling W @ -23°C Voltage Notes
SC18CLX 5/8 HP 17.69 cm³ 781W 220-240V 50Hz Direct replacement, same specs
SC21CL 3/4 HP 21.0 cm³ 920W 220-240V 50Hz Slightly higher capacity
SC15CL 1/2 HP 15.0 cm³ 650W 220-240V 50Hz Lower capacity option
SC18ML 5/8 HP 17.69 cm³ 850W 220-240V 50Hz MBP optimized variant
TFS4517Z 5/8 HP 17.2 cm³ 765W 220-240V 50Hz Tecumseh equivalent

5 Compressor Replacements – Alternative Refrigerants

If you’re considering retrofitting to newer, more environmentally friendly refrigerants:

Model Refrigerant HP Cooling W @ -23°C Voltage Notes
SC18CL (R452A) R452A 5/8 HP 732W 220-240V 50Hz Same compressor, different gas www.secop.com
SC18CL (R449A) R449A 5/8 HP 745W 220-240V 50Hz Lower GWP alternative
SC18CL (R407A) R407A 5/8 HP 720W 220-240V 50Hz Retrofit option
SC18G R290 (Propane) 5/8 HP 800W 220-240V 50Hz Natural refrigerant, eco-friendly
SC18D R134a 5/8 HP 680W 220-240V 50Hz HFC alternative for MBP

Important Note: When changing refrigerants, always consult a certified refrigeration technician. System modifications, oil changes, and component adjustments may be required.


Compatible Refrigerator/Freezer Models

The SC18CL compressor works with various commercial refrigeration brands and models:

Compatible Brands:

  • Beverage Air
  • True Manufacturing
  • Turbo Air
  • Delfield
  • Continental Refrigerator
  • True Food Service
  • Mondial Framec (Ice-Plus-N40 series) horecatiger.eu
  • Gram Commercial
  • Williams Refrigeration

Common Applications:

  • 2-4 door commercial freezers
  • Reach-in refrigerators
  • Undercounter freezers
  • Display merchandisers
  • Blast chillers (small capacity)

Installation & Maintenance Tips

Before Installation:

  1. Verify voltage matches your power supply (220-240V 50Hz)
  2. Ensure proper ventilation – compressor needs 3m/s airflow
  3. Check that refrigerant type matches your system
  4. Verify oil level and type (POE 32 cST)

During Installation:

  • Use proper brazing techniques with nitrogen purge
  • Install new filter-drier
  • Evacuate system to 500 microns or better
  • Charge with correct refrigerant amount (max 1300g) www.prokes-auto.com
  • Install proper starting components (relay + capacitors)

Maintenance Schedule:

  • Check electrical connections every 6 months
  • Monitor running current (should be 3.5-4.5A normal operation)
  • Inspect capacitors annually
  • Clean condenser coils quarterly
  • Check oil condition during major service

Troubleshooting Common Issues

Compressor won’t start:

  • Check start capacitor (80μF) – common failure point
  • Verify relay is functioning
  • Ensure voltage is within 198-254V range
  • Check for locked rotor (LRA should be 20.43A max)

Compressor runs but no cooling:

  • Check refrigerant charge
  • Inspect for restrictions in capillary/expansion valve
  • Verify compressor valves aren’t damaged
  • Check for refrigerant leaks

High current draw:

  • Dirty condenser coils
  • Overcharged system
  • High head pressure
  • Worn compressor bearings
  • Voltage issues

Frequent cycling:

  • Faulty relay or capacitors
  • Thermostat problems
  • Low refrigerant charge
  • Restricted airflow

Energy Efficiency & Operating Costs

The SC18CL offers decent efficiency for commercial refrigeration:

At -23.3°C evaporating temperature:

  • Cooling Capacity: 781W
  • Power Input: 660W
  • COP: 1.18
  • EER: 4.07

At -10°C evaporating temperature:

  • Cooling Capacity: 1,510W
  • Power Input: 933W
  • COP: 1.62
  • EER: 5.52

Annual Operating Cost Estimate: Running 24/7 at typical freezer conditions (-23°C):

  • Power consumption: ~5,782 kWh/year
  • Estimated cost: $690-870/year (at $0.12-0.15/kWh)

Where to Buy & Pricing

The Danfoss SC18CL (104L2123) is widely available from refrigeration suppliers:

Typical Price Range: €230-350 ($250-380 USD)

Authorized Distributors:

  • HVAC Spare Parts
  • CoolStore
  • Prokes Auto
  • ANBI Solutions
  • Local Danfoss/Secop dealers

What’s Included:

  • Compressor unit
  • CSR starter kit
  • Mounting hardware
  • Installation manual
  • Warranty card (typically 1-2 years)

Warranty & Support

Standard Warranty: 12-24 months from date of purchase

Coverage:

  • Manufacturing defects
  • Material failures
  • Workmanship issues

Not Covered:

  • Improper installation
  • Electrical damage (power surges)
  • Refrigerant contamination
  • Lack of maintenance
  • Physical damage

Support Resources:

  • Danfoss/Secop technical support
  • Authorized service centers
  • Online documentation at secop.com

Environmental Considerations

Refrigerant GWP (Global Warming Potential):

  • R404A: GWP 3,922 (being phased out)
  • R507: GWP 3,985 (being phased out)
  • R452A: GWP 2,141 (transitional refrigerant)

Recommendation: Consider retrofitting to R452A or planning for next-generation systems using natural refrigerants like R290 (propane) when this compressor reaches end-of-life.


Final Thoughts

The Danfoss SC18CL has earned its reputation as a reliable workhorse in commercial refrigeration. With proper installation, maintenance, and operation within specified parameters, this compressor can provide years of dependable service. Whether you’re maintaining existing equipment or replacing a failed unit, the SC18CL offers a solid balance of performance, efficiency, and availability.

Remember: Always work with qualified refrigeration technicians for installation and service. Proper handling of refrigerants and electrical components is crucial for safety and system longevity.


Focus Keyphrase: Danfoss SC18CL compressor R404A R507 specifications replacement 104L2123 commercial freezer refrigeration

SEO Title: Danfoss SC18CL Compressor | Complete Specs, Replacements & Performance Data | R404A/R507

Meta Description: Complete guide to Danfoss SC18CL compressor (104L2123). Technical specs, cooling capacity, replacement options, COP data. 5/8 HP, R404A/R507, LBP/MBP commercial refrigeration. Expert analysis & troubleshooting.

Slug: danfoss-sc18cl-compressor-specifications-replacements-r404a-r507

Tags: Danfoss SC18CL, Secop SC18CL, 104L2123, R404A compressor, R507 compressor, commercial freezer compressor, LBP compressor, MBP compressor, refrigeration compressor, SC18CL replacement, Danfoss compressor, Secop compressor, 5/8 HP compressor, CSCR compressor, commercial refrigeration, freezer compressor, beverage cooler compressor, display case compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, SC18CLX, SC21CL, SC15CL, compressor replacement, R452A compressor, hermetic compressor, piston compressor


Excerpt (First 55 words):

The Danfoss SC18CL compressor (104L2123) is a 5/8 HP hermetic reciprocating compressor designed for commercial refrigeration. Operating on R404A/R507 refrigerants at 220-240V 50Hz, it delivers 781W cooling capacity at -23°C for LBP/MBP applications. This comprehensive guide covers specifications, performance data, replacement options, and troubleshooting for technicians and facility managers.

Danfoss SC18CL compressor R404A R507 specifications replacement 104L2123 commercial freezer refrigeration mbsmpro
104L2123, 5/8 HP compressor, beverage cooler compressor, commercial freezer compressor, commercial refrigeration, Compressor Replacement, CSCR compressor, Danfoss compressor, Danfoss SC18CL, display case compressor, freezer compressor, Hermetic Compressor, LBP compressor, MBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R404A compressor, R452A compressor, R507 compressor, refrigeration compressor, SC15CL, SC18CL replacement, SC18CLX, SC21CL, Secop compressor, Secop SC18CL



Tecumseh CAJ9480T R22 Hermetic Compressor: Complete Technical Guide for Professionals

Tecumseh CAJ9480T R22 Hermetic Compressor: Complete Technical Guide for Professionals

The Tecumseh / L’Unité Hermetique CAJ9480T is a fully hermetic reciprocating compressor designed for commercial refrigeration systems operating with R22 and compatible retrofit refrigerants. Widely used in small cold rooms, display cabinets and compact condensing units, it runs on 220–240 V single‑phase, 50 Hz power and delivers 5/8 HP with around 1.97 kW of cooling capacity at EN12900 conditions.

General description

This model belongs to the CAJ family, Tecumseh’s workhorse range for medium and high back‑pressure refrigeration applications such as positive‑temperature cold rooms and commercial coolers. It is a hermetic piston compressor using a CSR motor (capacitor start, capacitor run), giving high starting torque and stable operation on standard single‑phase networks.

Manufactured in France under the L’Unité Hermetique brand, the CAJ9480T combines compact size, good efficiency and a robust mechanical design, which explains its popularity among installers and service companies like Mbsmgroup, Mbsm.pro and mbsmpro.com.

Main technical specifications (with HP and W)

The table below consolidates key data from Tecumseh specification sheets and trusted distributors.

Specification CAJ9480T value (R22, 50 Hz)
Refrigerant R22 (and some approved retrofits such as R438A on specific codes)
Application range Medium / high back pressure (commercial refrigeration)
Nominal horsepower (HP) 5/8 HP (0.625 HP)
Nominal cooling capacity (W) ≈ 1 968 W at EN12900: 220 V, 50 Hz, +5 °C evap / +50 °C cond
Input electrical power (W) ≈ 780–800 W at the same EN12900 rating point
Displacement 15.2 cm³/rev
Supply voltage 220–240 V, 1‑phase, 50 Hz
Voltage range 187–242 V (50 Hz)
Rated load amps (RLA, 50 Hz) ≈ 4 A
Locked rotor amps (LRA) ≈ 24 A
Oil type / quantity Synthetic alkylate or mineral, approx. 475–887 cm³ depending on version
Net weight ≈ 19–22 kg

The nameplate visible in your photo shows “R22 – LRA 24 – 203–220 V – 50 Hz – RLA 4.00”, matching these published values and confirming a single‑phase CAJ9480T produced in France.

Typical applications and field use

Because of its capacity, voltage and starting characteristics, the CAJ9480T fits many everyday refrigeration jobs.

  • Small cold rooms for butchers, restaurants, bakeries and mini‑markets originally charged with R22.
  • Vertical display cabinets, reach‑in fridges and refrigerated counters using factory‑built condensing units.
  • Custom‑built condensing units and mini‑packs produced by specialists such as Mbsmgroup, Mbsm.pro and mbsmpro.com, especially where reliable 5/8 HP performance is required on 230 V single‑phase.

Its CSR motor and high starting torque help the compressor start under tougher conditions, such as long pipe runs or marginal supply voltage.

Installation and maintenance best practices

Correct installation and servicing are essential to protect this compressor and keep systems efficient.

  • Flush and evacuate the circuit carefully, and always install a new filter‑drier when replacing a failed R22 compressor.
  • Use the start and run capacitors and potential relay recommended by Tecumseh (for example, 88 µF start and 15 µF run on the CAJ9480T‑FZ code) and follow the official wiring diagram.
  • Verify charge, suction superheat and condensing temperature so operation stays within Tecumseh’s performance envelope.
  • For R22 retrofit projects, respect manufacturer guidance on compatible replacement refrigerants and oil changes to avoid lubrication and overheating issues.

Working with trusted suppliers such as Mbsmgroup and its online platforms helps ensure genuine Tecumseh parts, correct electrical components and updated technical information.