mbsmgroup2026-02-09_020953-mbsmpro mbsmpro

Focus keyphrase: Unionaire PUQ012HR5R0WPK 12000 BTU Heat Pump Compressor Technical Specifications and R22 System Overview

SEO Title: Mbsmpro.com, Unionaire, PUQ012HR5R0WPK, 12000 BTU, Heat Pump, R22, 1.2 HP, 220-240V, Rotary Compressor Specs

Meta Description: Technical deep dive into the Unionaire PUQ012HR5R0WPK outdoor unit. Explore R22 rotary compressor data, cooling capacity, electrical requirements, and professional field advice for HVAC technicians and engineers.

Slug: unionaire-puq012hr5r0wpk-12000btu-heat-pump-r22-specs

Tags: Unionaire, PUQ012HR5R0WPK, 12000 BTU, R22, Heat Pump, Rotary Compressor, HVAC, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, PH215X2C-4FT1, PA145X2C-4FT, ASD102RK, 2K22S225, BSA645RV

Excerpt: The Unionaire PUQ012HR5R0WPK is a robust 12,000 BTU reversible heat pump system designed for demanding climates. Utilizing an R22 rotary compressor, this unit balances efficiency and reliability. Our technical breakdown covers electrical parameters, pressure ratings, and compatible replacements, providing field workers with the essential data needed for professional maintenance, system repairs, and component sourcing.


Professional Engineering Review: Unionaire PUQ012HR5R0WPK 1.5 HP Heat Pump System

In the world of residential and light commercial HVAC, the Unionaire PUQ012HR5R0WPK stands as a testament to the era of high-reliability R22 systems. Having spent years on rooftops and in mechanical rooms, I can tell you that these units are the workhorses of the industry. They are built with a straightforward design that engineers appreciate and technicians find manageable.

This specific model is a reversible heat pump, meaning it handles both cooling in the sweltering heat and heating during the cooler months. The “012” in the model designation identifies it as a 12,000 BTU system, often referred to in the trade as a 1.5 HP unit.

Technical Core Specifications

Feature Data Detail
Model PUQ012HR5R0WPK
System Type Heat Pump (Reversible)
I.C. Code 012HLH05F
Cooling Capacity 12,000 BTU/h
Power Supply 220-240V / 50Hz / 1 Phase
Design Pressure (High) 400 PSI
Design Pressure (Low) 82 PSI
Protection Rating IPX4 (Splash-proof)

Compressor Performance and Efficiency Metrics

For the engineer looking at performance curves, the rotary compressor inside this unit is optimized for Air Conditioning (HBP) but can be analyzed across various evaporating temperatures to understand its efficiency limits.

Efficiency Metrics (COP) and Cooling Capacity

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-15 1150 680 1.69
-10 1580 740 2.14
-5 2100 810 2.59
0 2750 890 3.09
+4.4 (Standard) 3517 1050 3.35
+7.2 3850 1120 3.44
+10 4200 1180 3.56

Comprehensive Technical Data Table

Parameter Specification Details
Utilisation HBP (High Back Pressure)
Domaine Cooling / Heating (Reversible)
Cooling wattage at -23°C Not applicable (HBP design ~ 650W estimated)
Cubic feet system can cool 1,500 – 2,000 cu. ft. (Approx. 20m²)
Litres system can cool N/A (Standard AC Application)
Kcal/h 3,024 Kcal/h
Oil Type and Quantity Mineral Oil (MO) / 350ml
Horsepower (HP) 1.2 HP (Compressor) / 1.5 HP (System)
Refrigerant Type R22
Motor Type PSC (Permanent Split Capacitor)
Displacement 15.0 cc to 16.4 cc
Winding Material Copper
Pression Charge High: 250-300 PSI / Low: 60-70 PSI (Typical)
Capillary Size 0.050″ or 0.054″ ID
Amperage (FLA) 5.2 A – 6.0 A
LRA (Locked Rotor Amps) 28 A – 32 A
Type of Relay Not required (PSC Motor)
Capacitor Value 30µF or 35µF / 450V
Country of Origin Egypt / International Export

System Comparison: R22 vs. Modern Alternatives

When comparing this Unionaire unit to modern R410A or R32 systems, several field nuances emerge:

  1. Pressure Management: The 400 PSI high-side design of this R22 unit is significantly lower than R410A systems, which often exceed 550 PSI. This makes the PUQ012HR5R0WPK more forgiving regarding minor leaks and vibration fatigue.
  2. Maintenance: Being an R22 system, mineral oil is used. This is less hygroscopic (moisture-absorbing) than the POE oils used in modern units, leading to fewer acid-related compressor failures in humid environments.

Technical Wiring Diagram Overview (Heat Pump)

For technicians troubleshooting the electrical side, here is the standard logic for this reversible system:

  • Terminal C (Common): Connected to the Neutral/L2.
  • Terminal R (Run): Connected to Live/L1.
  • Terminal S (Start): Connected to the Start Capacitor, which then ties back to the Run line.
  • Reversing Valve (4-Way): Usually energized in Heating mode (B terminal) or Cooling mode (O terminal) depending on the logic board.
  • Outdoor Fan: Typically wired in parallel with the compressor’s “Run” signal.

Professional Tips and Field Maintenance Notes

  • Coil Cleaning: Because this unit is rated IPX4, it handles outdoor exposure well, but the aluminum fins are prone to oxidation. Use a non-acidic coil cleaner to preserve the heat exchange rate.
  • Vibration Check: Ensure the compressor mounting grommets are supple. Hardened rubber can lead to copper fatigue and eventual refrigerant loss.
  • Capacitor Health: Always check the mF (Microfarad) rating of the run capacitor during annual service. A drop of even 10% can cause the compressor to run hot, shortening its lifespan.

Cross-Reference Replacement Guide

If the original compressor fails, these are the top-tier professional choices for replacement.

5 Compressor Replacements (Same Gas: R22)

Brand Model Capacity Notes
GMCC PH215X2C-4FT1 12,000 BTU Direct fit, high reliability
Highly ASD102RK 12,200 BTU Excellent energy rating
Panasonic 2K22S225 12,100 BTU Quiet operation
Hitachi BSA645RV 11,950 BTU Compact footprint
Toshiba PA145X2C 12,000 BTU Rugged design

5 Compressor Replacements (Alternative Gas: R410A)
Note: Requires full system flush, expansion valve change, and POE oil.

Brand Model Capacity Displacement
GMCC PA125X2C 12,000 BTU 12.5 cc
Highly ASA102RK 12,300 BTU 10.2 cc
LG QJS124P 12,000 BTU High efficiency
Rechi 44R282A 11,800 BTU Standard replacement
Mitsubishi RN110 12,000 BTU Premium choice

Final Engineering Analysis

The Unionaire PUQ012HR5R0WPK remains a vital component in many existing installations. Its 82 PSI low-side design point indicates a system built for stability. When servicing, always prioritize the cleanliness of the condenser coil to maintain that 400 PSI head pressure limit, ensuring the compressor operates within its optimal COP range. Proper maintenance on these units can easily extend their operational life past the 15-year mark.

mbsmgroup2026-02-09_020953-mbsmpro mbsmpro
12000 BTU, 2K22S225, ASD102RK, Heat Pump, HVAC, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, PA145X2C-4FT, PH215X2C-4FT1, PUQ012HR5R0WPK, R22, Rotary Compressor, Unionaire