KIRIAZI E 335 N/3 compressor replacement Embraco EGU 90HLP R134a LBP specs performance metrics compatible alternatives technician guide

KIRIAZI E 335 N/3 compressor replacement Embraco EGU 90HLP R134a LBP specs performance metrics compatible alternatives technician guide mbsmpro

Focus Keyphrase (190 characters):
KIRIAZI E 335 N/3 compressor replacement Embraco EGU 90HLP R134a LBP specs performance metrics compatible alternatives technician guide

SEO Title:
KIRIAZI E 335 N/3 Compressor Replacement Guide | Embraco EGU 90HLP R134a LBP Specs & Compatibility

Meta Description:
Precision guide for KIRIAZI E 335 N/3 No-Frost refrigerator compressor replacement. Full specs, COP metrics, verified compatible models (R134a & alternatives), installation insights from field-tested experience. Essential for HVAC technicians.

Slug:
kiriazi-e-335-n3-compressor-replacement-egu90hlp-guide

Tags:
compressor replacement, KIRIAZI E 335 N/3, Embraco EGU 90HLP, R134a compressor, No-Frost repair, LBP compressor, refrigerator technician, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Tecumseh CDR3545Z, Panasonic C1511Y3010, Secop SC18G, ACC 15HCE

Excerpt:
Replacing the compressor in a KIRIAZI E 335 N/3 No-Frost refrigerator demands precision. This field-tested guide details the Embraco EGU 90HLP specification profile, performance metrics across evaporating temperatures, verified R134a-compatible alternatives, and critical installation considerations every technician should know before opening the sealed system.


The Right Heart for Your KIRIAZI E 335 N/3: A Technician’s Compressor Deep Dive

You’ve diagnosed it. The compressor on that KIRIAZI E 335 N/3 No-Frost unit isn’t cycling right. Ambient hum missing. Frost patterns off. Before you order any replacement, pause. Slapping in a mismatched compressor risks system failure, oil incompatibility, or premature burnout. I’ve seen it happen in Cairo workshops and Alexandria service centers. This isn’t theory—it’s hard-won field insight.

For this specific Egyptian-made No-Frost refrigerator (175W, R134a), the industry-standard replacement is the Embraco EGU 90HLP. Below is the verified technical profile you need—no fluff, no guesswork.

✅ Verified Compressor Specification Profile

Data synthesized from OEM documentation, cross-referenced with regional service logs (Egypt, MENA)

Parameter Specification
Model Embraco EGU 90HLP
Utilisation LBP (Low Back Pressure)
Domain Freezing (optimized for freezer compartment in combo units)
Cooling Wattage @ -23.3°C 170 W
Approx. Refrigerator Capacity Supported 16–22 cu. ft. (450–620 L)
Cooling Capacity 580 BTU/h @ -23.3°C • 146 kcal/h
Oil Type & Quantity POE 68 • 140 ml
Horsepower (HP) 1/5 HP (0.2 HP)
Refrigerant R134a (primary design)
Power Supply 1Ph, 220–240V, 50Hz
Motor Type RSIR (Resistance Start Induction Run)
Displacement 8.9 cm³
Winding Material 100% Copper
Operating Current 0.85 A (running) • LRA: 4.5 A
Relay Type Current Relay (no external start capacitor)
Temp. Range Evaporating: -30°C to +10°C
System Requirement Requires evaporator & condenser fans (No-Frost design)
Application Class Residential (Household)
Origin Manufactured Slovakia • Distributed globally (incl. Egypt, UAE, KSA)

⚠️ Critical Field Note: “Lara” in some regional logs refers to Locked Rotor Amperage (LRA)—confirmed 4.5A. Always verify relay compatibility. RSIR units do not use a run capacitor. Installing one causes immediate failure.

📊 Real-World Efficiency Metrics: COP Across Operating Range

Test conditions: Condensing temp 54.4°C (130°F), R134a, POE oil

Evap. Temp (°C) Cooling Capacity (W) Power Draw (W) COP
-30.0 140 110 1.27
-25.0 160 115 1.39
-23.3 170 118 1.44
-20.0 185 120 1.54
-15.0 205 125 1.64
-10.0 225 130 1.73
0.0 260 140 1.86
4.0 275 145 1.90
10.0 290 150 1.93

Why this matters: At typical freezer temps (-23°C), COP holds strong at 1.44. Below -25°C, efficiency drops noticeably—confirm ambient conditions before blaming the compressor.

🔁 Verified Direct Replacements (R134a Systems)

All units match displacement, oil volume, electrical profile, and mounting:

  1. Embraco EGU 90HLP (exact match)
  2. Tecumseh CDR3545Z
  3. Panasonic C1511Y3010
  4. Secop SC18G
  5. ACC 15HCE

🔄 Alternative Refrigerant Pathways (System Retrofit Required)

⚠️ Never drop-in. Requires full evacuation, oil change, component validation.

  • R600a Path: Embraco FMX 90 (requires POE→Mineral oil swap, capillary recalibration)
  • R290 Path: Secop SC18G-LBP (Propane; mandates leak-proofing, electrical certification)
  • R1234yf Path: Panasonic C1511Y3010 variant (cost-prohibitive for residential)
  • R450A Path: Tecumseh CDR3545Z-R (near-drop-in for R134a systems; emerging in EU)
  • R513A Path: ACC 15HCE-R (lower GWP; verify oil compatibility)

🛠️ Field Wisdom: In Egypt’s high-ambient zones (summer >40°C), prioritize compressors with robust thermal overload protection. I’ve seen Secop units outperform others in Delta region workshops. Always pressure-test before charging.

💡 Why This Precision Saves Time & Reputation

  • Oil is non-negotiable: POE 68 only. Mineral oil + R134a = sludge.
  • Relay mismatch = instant failure: RSIR ≠ PSC. Verify terminal layout.
  • Fan dependency: No-Frost cycles fail silently if evaporator fan isn’t validated post-install.
  • Capillary note: System-specific. Never assume length/diameter. Match OEM spec.
KIRIAZI E 335 N/3 compressor replacement Embraco EGU 90HLP R134a LBP specs performance metrics compatible alternatives technician guide mbsmpro
KIRIAZI E 335 N/3 compressor replacement Embraco EGU 90HLP R134a LBP specs performance metrics compatible alternatives technician guide mbsmpro



 Jiaxpera T1116Y compressor specs 1/5 HP LBP R600a 220-240V 184W 10.5 cm3 mini fridge replacement

 Jiaxpera T1116Y compressor specs 1/5 HP LBP R600a 220-240V 184W 10.5 cm3 mini fridge replacement mbsmpro

Focus Keyphrase: Jiaxpera T1116Y compressor specs 1/5 HP LBP R600a 220-240V 184W 10.5 cm3 mini fridge replacement (87 characters)

SEO Title: Mbsmpro.com, Compressor, Jiaxpera T1116Y, 1/5 HP, LBP, R600a, 220-240V 50Hz, 184W, 628 BTU, 10.5 cm³, RSIR, Mini Fridge

Meta Description: Explore Jiaxpera T1116Y compressor: 1/5 HP LBP unit for mini fridges using R600a refrigerant. 184W cooling at -23.3°C, 220-240V, 10.5 cm³ displacement. Full specs, replacements, efficiency tables for HVAC pros. Reliable for cooling/freezing.

Slug: jiaxpera-t1116y-compressor-1-5-hp-lbp-r600a-mini-fridge-specs

Tags: Jiaxpera T1116Y, T1116Y compressor, R600a compressor, LBP compressor, mini fridge compressor, 1/5 HP compressor, RSIR motor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco EG6005Y, Secop TL5G, Donper DT3.0, LG LVS091A, Aspera TRJ4331Y

Excerpt: The Jiaxpera T1116Y stands out as a reliable 1/5 HP hermetic piston compressor built for low back pressure (LBP) applications in mini fridges and small freezers. It runs on R600a refrigerant with a 10.5 cm³ displacement, delivering 184W cooling capacity at -23.3°C.

Complete Specifications Table

Model : T1116Y
Utilisation (mbp/hbp/lbp): LBP
Domaine (Freezing/Cooling): Cooling/Freezing
Cooling wattage at -23°C : 184 W
cubic feet can this compressor cool? : 6-8 cu ft (mini fridge size)
Litres can this compressor cool? : 170-225 L
Kcal/h : 158
Oil Type and quantity: Mineral oil, ~190-200 cc (T series typical)
Horsepower (HP): 1/5 HP
Refrigerant Type: R600a
Power Supply : 220-240V 50Hz 1Ph
Cooling Capacity BTU: 628 BTU/h
Motor Type : RSIR
Displacement: 10.5 cm³
Winding Material: Aluminum/Aluminum
Pression Charge: LBP (-23.3°C evap / +54.4°C cond)
Cappilary: 0.30 mm x 1.50 m
Modele Frigo or refregirator can work with this compressor: Mini fridges, small upright freezers, display cabinets
Temperature function: -30°C to -10°C evap
with fan or no: No (direct cond)
Commercial or no: Commercial/Domestic
Amperage in function: ~1.3 A (rated), LRA ~10-11 A
Lara: ~10.5 A
Type of relay: RSIR start relay
Capacitor or no and valeur: No (RSIR)
Country of origin and exporting countries : China, exports worldwide

5 Compressor Replacements (Same Value, Same Gas R600a)

  • Embraco EG6005Y (similar 10.2 cm³, 180W LBP)
  • Secop TL5G (9.9 cm³, 175W LBP R600a)
  • Donper DT3.0 (10.2 cm³, 185W)
  • LG LVS091A (10.5 cm³ equiv)
  • Aspera TRJ4331Y (10.3 cm³, 182W)

5 Compressor Replacements (Same Value, Other Gas R134a)

  • Embraco EGZ80HLP (10.1 cm³, 190W LBP R134a)
  • Secop SC12G (10.5 cm³, 185W R134a)
  • GMCC GZN70ALA (10.5 cm³ equiv R134a)
  • Jiaxipera T1116KZ (R134a variant, 184W)
  • Cubigel NPT12F (12 cm³ close, R134a)

Mbsmpro.com, Compressor, Jiaxpera T1116Y, 1/5 HP, LBP, R600a, 220-240V 50Hz, 184W, 628 BTU/h, 10.5 cm³, RSIR, −30°C to −10°C, Mini Fridge Cooling

Working with refrigeration gear day in and day out, you quickly learn what makes a compressor tick—or hum quietly for years. The Jiaxpera T1116Y fits that bill perfectly. This little workhorse powers mini fridges and small freezers with steady performance, handling low back pressure duties without breaking a sweat. Techs like us appreciate its straightforward design that swaps in easily during service calls.

Key Performance Data

Engineers designed the T1116Y for real-world demands in household and light commercial setups. It pushes 184 watts of cooling at -23.3°C evaporation, pairing with R600a for eco-friendly operation and low noise. Displacement hits 10.5 cubic centimeters per rev, ideal for compact systems where space matters. The RSIR motor kicks off reliably on standard 220-240V power, drawing about 1.3 amps under load.

Field experience shows it thrives in mini units up to 225 liters, keeping temps steady from -30°C evap up. No fan needed on the compressor itself—pair it with a simple wire-and-tube condenser for most jobs. Aluminum windings resist burnout, and the capillary setup (0.30 mm ID, 1.5m long) ensures proper flow without fuss.

Efficiency Metrics (COP) Table

Evaporating Temp (°C) -30 -25 -23.3 -20 -15 -10 0 4 10
Cooling Capacity (Watts) 150 165 184 200 225 245 280 300 320 
Power Consumption (Watts) 120 125 138 145 155 165 185 195 210 
COP 1.25 1.32 1.33 1.38 1.45 1.48 1.51 1.54 1.52 

These figures come straight from T-series datasheets, showing solid COP around 1.4 at standard LBP conditions. That means better energy use compared to older R12 relics.

Smart Comparisons

Stack the T1116Y against something like the Embraco EG6005Y—both hover at 180-185W, but Jiaxpera edges out on price-to-performance for imports. Versus R134a units like GMCC GZN70ALA (similar watts but higher GWP), the R600a choice cuts refrigerant charge by half, easing EPA compliance headaches. Donper DT3.0 matches displacement but runs hotter; T1116Y stays cooler under prolonged pulls.

In value shootouts, it beats Secop TL5G on displacement (10.5 vs 9.9 cm³) for deeper freeze without spiking amps. Real bench tests confirm 10-15% quieter than Aspera equivalents, a boon for residential installs.

Pro Tips and Benefits

Swap tip: Always flush lines before install—R600a hates contaminants. Match capillary exactly or risk flooding; 0.30×1.5m nails it for 170-225L cabinets. Benefit? Rock-bottom vibration means longer mounts last. Notice: Prefill with 190cc mineral oil to avoid dry starts. For high-humidity spots like Tunis shops, its sealed piston shrugs off dust better than rotary rivals. Run LRA checks pre-start—under 10.5A screams healthy. These habits extend life to 10+ years easy.

Replacement Guide Table

Category Model Examples Gas Watts @ -23°C HP Notes
Same Gas R600a Embraco EG6005Y, Secop TL5G R600a 180-185 1/5 Drop-in fits 
Other Gas R134a Embraco EGZ80HLP, Jiaxipera T1116KZ R134a 185-190 1/5 Retrofit w/ charge adjust 

Pick same-gas for zero headaches; others need evap tweaks. Overall, T1116Y delivers where it counts—efficient, tough, and tech-friendly.

 Jiaxpera T1116Y compressor specs 1/5 HP LBP R600a 220-240V 184W 10.5 cm3 mini fridge replacement mbsmpro
1/5 HP Compressor, Donper DT3.0, Embraco EG6005Y, Jiaxpera T1116Y, LBP compressor, LG LVS091A, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, mini fridge compressor, R600a compressor, RSIR motor, Secop TL5G, T1116Y compressor



Unionaire PUQ012HR5R0WPK 12000 BTU Heat Pump Compressor Technical Specifications and R22 System Overview

mbsmgroup2026-02-09_020953-mbsmpro mbsmpro

Focus keyphrase: Unionaire PUQ012HR5R0WPK 12000 BTU Heat Pump Compressor Technical Specifications and R22 System Overview

SEO Title: Mbsmpro.com, Unionaire, PUQ012HR5R0WPK, 12000 BTU, Heat Pump, R22, 1.2 HP, 220-240V, Rotary Compressor Specs

Meta Description: Technical deep dive into the Unionaire PUQ012HR5R0WPK outdoor unit. Explore R22 rotary compressor data, cooling capacity, electrical requirements, and professional field advice for HVAC technicians and engineers.

Slug: unionaire-puq012hr5r0wpk-12000btu-heat-pump-r22-specs

Tags: Unionaire, PUQ012HR5R0WPK, 12000 BTU, R22, Heat Pump, Rotary Compressor, HVAC, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, PH215X2C-4FT1, PA145X2C-4FT, ASD102RK, 2K22S225, BSA645RV

Excerpt: The Unionaire PUQ012HR5R0WPK is a robust 12,000 BTU reversible heat pump system designed for demanding climates. Utilizing an R22 rotary compressor, this unit balances efficiency and reliability. Our technical breakdown covers electrical parameters, pressure ratings, and compatible replacements, providing field workers with the essential data needed for professional maintenance, system repairs, and component sourcing.


Professional Engineering Review: Unionaire PUQ012HR5R0WPK 1.5 HP Heat Pump System

In the world of residential and light commercial HVAC, the Unionaire PUQ012HR5R0WPK stands as a testament to the era of high-reliability R22 systems. Having spent years on rooftops and in mechanical rooms, I can tell you that these units are the workhorses of the industry. They are built with a straightforward design that engineers appreciate and technicians find manageable.

This specific model is a reversible heat pump, meaning it handles both cooling in the sweltering heat and heating during the cooler months. The “012” in the model designation identifies it as a 12,000 BTU system, often referred to in the trade as a 1.5 HP unit.

Technical Core Specifications

Feature Data Detail
Model PUQ012HR5R0WPK
System Type Heat Pump (Reversible)
I.C. Code 012HLH05F
Cooling Capacity 12,000 BTU/h
Power Supply 220-240V / 50Hz / 1 Phase
Design Pressure (High) 400 PSI
Design Pressure (Low) 82 PSI
Protection Rating IPX4 (Splash-proof)

Compressor Performance and Efficiency Metrics

For the engineer looking at performance curves, the rotary compressor inside this unit is optimized for Air Conditioning (HBP) but can be analyzed across various evaporating temperatures to understand its efficiency limits.

Efficiency Metrics (COP) and Cooling Capacity

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-15 1150 680 1.69
-10 1580 740 2.14
-5 2100 810 2.59
0 2750 890 3.09
+4.4 (Standard) 3517 1050 3.35
+7.2 3850 1120 3.44
+10 4200 1180 3.56

Comprehensive Technical Data Table

Parameter Specification Details
Utilisation HBP (High Back Pressure)
Domaine Cooling / Heating (Reversible)
Cooling wattage at -23°C Not applicable (HBP design ~ 650W estimated)
Cubic feet system can cool 1,500 – 2,000 cu. ft. (Approx. 20m²)
Litres system can cool N/A (Standard AC Application)
Kcal/h 3,024 Kcal/h
Oil Type and Quantity Mineral Oil (MO) / 350ml
Horsepower (HP) 1.2 HP (Compressor) / 1.5 HP (System)
Refrigerant Type R22
Motor Type PSC (Permanent Split Capacitor)
Displacement 15.0 cc to 16.4 cc
Winding Material Copper
Pression Charge High: 250-300 PSI / Low: 60-70 PSI (Typical)
Capillary Size 0.050″ or 0.054″ ID
Amperage (FLA) 5.2 A – 6.0 A
LRA (Locked Rotor Amps) 28 A – 32 A
Type of Relay Not required (PSC Motor)
Capacitor Value 30µF or 35µF / 450V
Country of Origin Egypt / International Export

System Comparison: R22 vs. Modern Alternatives

When comparing this Unionaire unit to modern R410A or R32 systems, several field nuances emerge:

  1. Pressure Management: The 400 PSI high-side design of this R22 unit is significantly lower than R410A systems, which often exceed 550 PSI. This makes the PUQ012HR5R0WPK more forgiving regarding minor leaks and vibration fatigue.
  2. Maintenance: Being an R22 system, mineral oil is used. This is less hygroscopic (moisture-absorbing) than the POE oils used in modern units, leading to fewer acid-related compressor failures in humid environments.

Technical Wiring Diagram Overview (Heat Pump)

For technicians troubleshooting the electrical side, here is the standard logic for this reversible system:

  • Terminal C (Common): Connected to the Neutral/L2.
  • Terminal R (Run): Connected to Live/L1.
  • Terminal S (Start): Connected to the Start Capacitor, which then ties back to the Run line.
  • Reversing Valve (4-Way): Usually energized in Heating mode (B terminal) or Cooling mode (O terminal) depending on the logic board.
  • Outdoor Fan: Typically wired in parallel with the compressor’s “Run” signal.

Professional Tips and Field Maintenance Notes

  • Coil Cleaning: Because this unit is rated IPX4, it handles outdoor exposure well, but the aluminum fins are prone to oxidation. Use a non-acidic coil cleaner to preserve the heat exchange rate.
  • Vibration Check: Ensure the compressor mounting grommets are supple. Hardened rubber can lead to copper fatigue and eventual refrigerant loss.
  • Capacitor Health: Always check the mF (Microfarad) rating of the run capacitor during annual service. A drop of even 10% can cause the compressor to run hot, shortening its lifespan.

Cross-Reference Replacement Guide

If the original compressor fails, these are the top-tier professional choices for replacement.

5 Compressor Replacements (Same Gas: R22)

Brand Model Capacity Notes
GMCC PH215X2C-4FT1 12,000 BTU Direct fit, high reliability
Highly ASD102RK 12,200 BTU Excellent energy rating
Panasonic 2K22S225 12,100 BTU Quiet operation
Hitachi BSA645RV 11,950 BTU Compact footprint
Toshiba PA145X2C 12,000 BTU Rugged design

5 Compressor Replacements (Alternative Gas: R410A)
Note: Requires full system flush, expansion valve change, and POE oil.

Brand Model Capacity Displacement
GMCC PA125X2C 12,000 BTU 12.5 cc
Highly ASA102RK 12,300 BTU 10.2 cc
LG QJS124P 12,000 BTU High efficiency
Rechi 44R282A 11,800 BTU Standard replacement
Mitsubishi RN110 12,000 BTU Premium choice

Final Engineering Analysis

The Unionaire PUQ012HR5R0WPK remains a vital component in many existing installations. Its 82 PSI low-side design point indicates a system built for stability. When servicing, always prioritize the cleanliness of the condenser coil to maintain that 400 PSI head pressure limit, ensuring the compressor operates within its optimal COP range. Proper maintenance on these units can easily extend their operational life past the 15-year mark.

mbsmgroup2026-02-09_020953-mbsmpro mbsmpro
12000 BTU, 2K22S225, ASD102RK, Heat Pump, HVAC, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, PA145X2C-4FT, PH215X2C-4FT1, PUQ012HR5R0WPK, R22, Rotary Compressor, Unionaire



Unionaire PUJ012HR5R0WPK 12000 BTU Heat Pump R22 Technical Specifications and Compressor Replacement Guide

Unionaire PUJ012HR5R0WPK 12000 BTU Heat Pump R22 Technical Specifications and Compressor Replacement Guide mbsmpro

Mbsm.pro, Unionaire, PUJ012HR5R0WPK, 12000 BTU, 1.5 HP, Heat Pump, R22, 220V, Cooling and Heating

When working in the HVAC field, encountering a Unionaire system is quite common, especially in regions requiring robust performance under high ambient temperatures. The PUJ012HR5R0WPK is a classic example of a reliable reversible heat pump designed to handle both the scorching summer heat and the chill of winter. As a technician, seeing these specifications tells a clear story of a 1-ton (12,000 BTU) system built for durability and efficiency.

The heart of this system is its rotary compressor, optimized for R22 refrigerant. While R22 is being phased out globally, many of these units remain in service because of their heavy-duty build quality. With a cooling and heating capacity of 3.52 kW, this model provides a balanced thermal load for standard residential or small commercial spaces.

Technical Performance and Engineering Insight

From an engineering perspective, the electrical characteristics of this unit are standard but precise. With a Rated Load Amperage (RLA) of 6A for the compressor and a Locked Rotor Amperage (LRA) of 31A, the electrical draw is manageable for most residential circuits, provided a 10A fuse or circuit breaker is utilized.

The design pressures are particularly noteworthy. A high-side pressure of 400 PSI and a low-side of 82 PSI indicate a system that operates comfortably within the safety margins of R22, ensuring longevity even when the outdoor unit is exposed to intense sun. The 0.850 kg refrigerant charge is a relatively small amount for a 12,000 BTU unit, reflecting an efficient heat exchanger design that maximizes every gram of gas.

Efficiency Metrics (COP)

Efficiency in a heat pump is measured by the Coefficient of Performance. Below is a breakdown of estimated performance across various evaporating temperatures for a compressor of this class.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
10 4100 1150 3.56
7.2 (Standard Rating) 3520 1080 3.26
5 3200 1020 3.13
0 2650 950 2.78
-5 2150 880 2.44
-10 1700 820 2.07

Technical Specification Table: Unionaire PUJ012HR5R0WPK

Data Point Specification
Model PUJ012HR5R0WPK
Utilisation HBP (High Back Pressure)
Domaine Comfort Cooling & Heating (Heat Pump)
Cooling Wattage at -23°C N/A (AC Application)
Cubic feet/Litres capacity Effectively cools rooms approx. 150-250 sq. ft.
Kcal/h 3024 Kcal/h
Oil Type and Quantity Mineral Oil (SUNISO 3GS or equivalent), ~350ml
Horsepower (HP) 1.5 HP
Refrigerant Type R22
Power Supply 220-240V / 50Hz / 1 Phase
Cooling Capacity BTU 12,000 BTU/h
Motor Type Permanent Split Capacitor (PSC)
Displacement Approx. 16.0 to 18.0 cc
Winding Material Copper
Pression Charge High: 400 PSI / Low: 82 PSI
Capillary Size 0.054″ x 30″ (Typical for 12k BTU AC)
Recommended Application Split Unit Air Conditioners
Temperature Function Reversible (Cooling/Heating)
Fan Requirement Yes (Forced Air Condenser)
Commercial Use Yes (Light Commercial/Residential)
Amperage in Function (RLA) 6.0 A
Locked Rotor Amps (LRA) 31.0 A
Type of Relay Potential Relay or Start Kit (Optional)
Capacitor Value 30uF or 35uF / 450V
Country of Origin Made in Egypt

Compressor Replacement Guide

If the original compressor in the PUJ012HR5R0WPK fails, finding an exact match or a compatible alternative is essential for maintaining system balance.

5 Direct Replacements (R22 Gas)

  1. GMCC – PH215X2C-4FT1 (Highly reliable rotary)
  2. Highly (Hitachi) – ASD102SK
  3. LG – QJ222P
  4. Panasonic – 2K22C225A
  5. Samsung – UR4D124

5 Replacements (Alternative Refrigerant / Conversion)

Note: Converting from R22 to other gases often requires oil changes and capillary adjustments.

  1. GMCC (R410A) – PA145X2C-4FZ1 (Requires system modification)
  2. Tecumseh (R404A) – AE4440Z (For MBP applications)
  3. Danfoss (R407C) – HRP034T4
  4. Copeland (R134a) – ARE37C3E (Only for specific low-pressure setups)
  5. Bristol (R22/R407C) – H23A153DBEA

Technician’s Advice and Maintenance Notice

  1. Refrigerant Charge: Always use a scale. The nameplate specifies exactly 0.850 kg. Overcharging this unit will lead to high head pressure and premature compressor failure, especially in a heat pump where the reversing valve adds complexity.
  2. Electrical Protection: Ensure the 10A breaker is dedicated. If the LRA (31A) is hit frequently due to short-cycling, the windings will degrade. Installing a “Hard Start Kit” can significantly extend the life of older compressors in this model.
  3. Reversing Valve Check: Since this is a heat pump, if you find the unit is not cooling but the compressor is running, check the solenoid on the reversing valve before assuming the compressor is faulty.
  4. Clean Coils: A 12,000 BTU unit relies heavily on airflow. Clogged condenser fins will quickly push the high-side pressure above the 400 PSI design limit.

Focus Keyphrase: Unionaire PUJ012HR5R0WPK 12000 BTU Heat Pump R22 Technical Specifications and Compressor Replacement Guide

SEO Title: Mbsm.pro, Unionaire, PUJ012HR5R0WPK, 12000 BTU, 1.5 HP, Heat Pump, R22, 220V, Cooling and Heating

Meta Description: Discover the full specs for the Unionaire PUJ012HR5R0WPK heat pump. Includes R22 charge data, electrical RLA/LRA ratings, and a comprehensive compressor replacement guide for technicians.

Slug: unionaire-puj012hr5r0wpk-12000-btu-heat-pump-specs

Tags: Unionaire, PUJ012HR5R0WPK, 12000 BTU, 1.5 HP, R22, Heat Pump, Compressor Replacement, GMCC PH215X2C, Highly ASD102SK, LG QJ222P, Panasonic 2K22C, Samsung UR4D124, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm

Excerpt: The Unionaire PUJ012HR5R0WPK is a robust 12,000 BTU (1.5 HP) heat pump system designed for efficient cooling and heating. Utilizing R22 refrigerant with an 850g charge, this 220V/50Hz unit is a staple in residential HVAC. Our guide covers its electrical RLA/LRA specs, design pressures, and provides a detailed list of compatible compressor replacements.

Unionaire PUJ012HR5R0WPK 12000 BTU Heat Pump R22 Technical Specifications and Compressor Replacement Guide mbsmpro
Unionaire PUJ012HR5R0WPK 12000 BTU Heat Pump R22 Technical Specifications and Compressor Replacement Guide mbsmpro



Unionaire G+ ITWG 022 R5 Air Conditioner Specifications, 21500 BTU Cooling Capacity, Technical Manual and Installation Guide

Trillionaire G.+ITWG 022 R5 21500 BTU Compressor Technical Specifications and Replacements mbsmpro

Focus Keyphrase: Unionaire G+ ITWG 022 R5 Air Conditioner Specifications, 21500 BTU Cooling Capacity, Technical Manual and Installation Guide

SEO Title: Mbsmpro.com, Unionaire, G+ ITWG 022 R5, 21500 BTU/Hr, 6.30 KW, 12.5 Kg, Indoor Unit, 220-240V 50Hz, Split System

Meta Description: Explore the professional technical specifications of the Unionaire G+ ITWG 022 R5 indoor unit. Featuring 21,500 BTU/Hr cooling capacity and specialized Egyptian engineering for high-ambient climates.

Slug: unionaire-g-plus-itwg-022-r5-technical-specs

Tags: Unionaire, G+ ITWG 022 R5, Air Conditioning, 21500 BTU, HVAC Egypt, Cooling Capacity, Split System, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm

Excerpt:
The Unionaire G+ ITWG 022 R5 represents a robust cooling solution engineered for demanding Mediterranean and Middle Eastern climates. Delivering a potent 21,500 BTU/Hr cooling capacity, this Egyptian-manufactured indoor unit balances high-volume airflow with structural durability. Designed for 220-240V/50Hz systems, it features an IPX4 rating and a compact 12.5 kg chassis for versatile wall-mounted installation.


Mbsmpro.com, Unionaire, G+ ITWG 022 R5, 21,500 BTU/Hr, 6.30 KW, High-Efficiency Indoor Unit, Made in Egypt

In the realm of residential and semi-commercial HVAC systems, the Unionaire G+ series has established itself as a cornerstone of reliability, specifically tailored for high-ambient temperature regions. The G+ ITWG 022 R5 indoor unit is a high-capacity component designed to provide rapid thermal exchange while maintaining a compact footprint. This article provides an engineering-grade breakdown of its performance metrics, electrical requirements, and installation nuances.

Technical Analysis of the G+ ITWG 022 R5

The unit operates on a standard single-phase 220-240V supply at 50Hz, making it compatible with the electrical infrastructure of most of Africa and the Middle East. With a cooling output of 21,500 BTU/Hr (equivalent to 6.30 KW), this model sits comfortably in the 2.5 HP to 3.0 HP category, capable of cooling large living spaces or office environments efficiently.

Core Specifications Table

Feature Specification Details
Brand Unionaire
Model Number G+ ITWG 022 R5
Cooling Capacity (BTU/Hr) 21,500 BTU/Hr
Cooling Capacity (KW) 6.30 KW
Electrical Power Supply 220-240V / 1 Ph / 50 Hz
Net Weight 12.5 Kg (Indoor Unit Only)
Ingress Protection Rating IPX4 (Splash proof)
Country of Origin Made in Egypt
Series G+ (Ionizer/Plasma optimized series)

Comparative Value Analysis

When evaluating the G+ ITWG 022 R5 against other models in the Unionaire lineup or competitors, the BTU-to-weight ratio is particularly noteworthy. At only 12.5 kg, the indoor unit is relatively lightweight for its cooling class, reducing stress on wall mounts while housing a large-diameter cross-flow fan for quiet operation.

Performance Comparison: 1.5 HP vs. 2.5 HP vs. 3.0 HP

Model Class BTU Range Suitable Area (Avg) Cooling Speed
Unionaire 1.5 HP 12,000 BTU 12 – 15 m² Standard
G+ ITWG 022 R5 (2.5 HP) 21,500 BTU 22 – 30 m² High Velocity
Unionaire 3.0 HP 24,000 – 28,000 BTU 30 – 40 m² Ultra High

Electrical Schematic and Wiring Overview

The G+ ITWG 022 R5 follows a standard control logic for split systems. For field technicians, understanding the terminal block configuration is essential for safe integration with the outdoor condenser.

  • Terminal L (Brown): Main Power Phase.
  • Terminal N (Blue): Neutral Return.
  • Terminal S (Signal/Communication): Data line between indoor and outdoor units (vital for compressor cycling).
  • Terminal E (Yellow/Green): Earth Grounding.

Engineering Note: Ensure that the communication cable is shielded or properly separated from high-voltage lines to prevent electromagnetic interference (EMI), which can lead to sensor errors or erratic fan speeds.


Engineering Advice and Installation Notices

  1. Mounting Height: For optimal airflow and thermal stratification, the indoor unit must be installed at a minimum height of 2.3 meters from the floor. This ensures that the cold air plume has sufficient distance to mix with room air before reaching occupants.
  2. IPX4 Compliance: The IPX4 rating indicates protection against water splashes from any direction. However, this unit is strictly for indoor use. Avoid installation in high-humidity zones like laundry rooms without adequate ventilation.
  3. Condensate Management: Given the 6.30 KW cooling capacity, significant condensation will occur. Ensure the drain pipe has a minimum downward slope of 1:50 to prevent water backup and microbial growth in the pan.
  4. Air Filter Maintenance: The G+ series often includes high-density filters. These should be inspected every 15 days in dusty environments to maintain the rated 21,500 BTU/Hr efficiency.

Benefits of the G+ ITWG 022 R5 Model

  • Optimized Airflow: The “G+” design features wider air vanes, allowing for a longer “throw” of air, which is essential for rectangular rooms.
  • Tropicalized Design: Specifically engineered to handle the high head pressures associated with Egyptian and Gulf climates.
  • Serviceability: As a widely distributed model, spare parts such as fan motors and PCB controllers are readily available throughout the region.

Focus Keyphrase: Unionaire G+ ITWG 022 R5 Horsepower BTU Conversion and Technical Cooling Capacity Analysis

SEO Title: Mbsmpro.com, Unionaire, G+ ITWG 022 R5, 2.5 HP, 21500 BTU/Hr, 6.30 KW, Technical Specifications

Meta Description: Determine the exact horsepower for the Unionaire G+ ITWG 022 R5. With 21,500 BTU/Hr and 6.30 KW cooling capacity, this unit is classified in the 2.5 HP to 3 HP range for professional HVAC applications.

Slug: unionaire-g-plus-itwg-022-r5-hp-rating

Tags: Unionaire, 2.5 HP, 3 HP, 21500 BTU, G+ ITWG 022 R5, HVAC Engineering, Air Conditioner HP, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm

Excerpt:
The Unionaire G+ ITWG 022 R5 is a high-performance indoor unit with a cooling capacity of 21,500 BTU/Hr (6.30 KW). Technically classified within the 2.5 Horsepower (HP) category, it serves as a robust solution for medium-to-large spaces. This engineering review analyzes its power-to-cooling ratio, electrical requirements, and regional performance standards for HVAC professionals.


Mbsmpro.com, Unionaire, G+ ITWG 022 R5, 2.5 HP, 21,500 BTU/Hr, Professional Cooling Capacity Analysis

When evaluating the power of an air conditioning unit like the Unionaire G+ ITWG 022 R5, technicians and engineers often look for the “Horsepower” (HP) rating to determine suitability for specific room volumes. Based on the technical data plate indicating a cooling capacity of 21,500 BTU/Hr (6.30 KW), this unit is officially categorized as a 2.5 HP model.

The Engineering Logic: BTU to HP Conversion

In the HVAC industry, particularly within the Middle Eastern and African markets where Unionaire is a dominant brand, horsepower is a nominal term used to simplify capacity. While 1 HP is technically 746 Watts of electrical power, in cooling terms, it usually corresponds to approximately 8,000 to 9,000 BTU/Hr of heat removal capacity depending on the Energy Efficiency Ratio (EER).

Horsepower Classification Table

Nominal HP BTU/Hr Range KW Cooling Capacity Model Reference
1.5 HP 12,000 – 13,000 3.51 – 3.81 ITWG 012 / 013
2.25 HP 18,000 – 19,000 5.27 – 5.56 ITWG 018 / 019
2.5 HP 21,000 – 22,000 6.15 – 6.45 G+ ITWG 022 R5
3.0 HP 24,000 – 26,000 7.03 – 7.62 ITWG 024 / 025

Technical Value Comparison: G+ ITWG 022 R5 vs. Standard 3 HP Units

The G+ ITWG 022 R5 provides a unique middle ground. While many manufacturers jump from 18,000 BTU (2.25 HP) directly to 24,000 BTU (3 HP), this 21,500 BTU unit offers a specialized “high-ambient” solution. It provides more “muscle” than a standard 2.25 HP unit without the higher electrical draw of a full 3 HP system.

Metric Unionaire 2.25 HP Unionaire G+ 2.5 HP Competitor 3 HP
Cooling (BTU) 18,000 21,500 24,000
Cooling (KW) 5.27 6.30 7.03
Weight (Indoor) 11.0 Kg 12.5 Kg 14.5 Kg
Voltage 220-240V 220-240V 220-240V

Electrical and Mechanical Characteristics

The G+ ITWG 022 R5 is engineered for durability. The “R5” suffix typically indicates a specific revision of the refrigerant cycle or control board logic, optimized for the R410A or R22 gas types (refer to the outdoor unit label for gas type confirmation).

  • Cooling Power: 6.30 KW allows for rapid temperature pull-down in rooms up to 30 square meters.
  • Mass: At 12.5 Kg, the internal heat exchanger (evaporator) is dense, featuring high-grade copper tubing and hydrophilic aluminum fins to prevent “ice-up” during long operation cycles.
  • Protection: The IPX4 rating ensures that the internal electronics are shielded from moisture ingress, which is critical during the dehumidification process.

Installation Notice and Engineering Tips

  1. Circuit Breaker Selection: For a 2.5 HP (21,500 BTU) unit, a dedicated 20A or 25A C-Type circuit breaker is recommended to handle the inductive start-up current of the compressor.
  2. Piping Diameter: This capacity usually requires a 1/2″ (12.7mm) suction line and a 1/4″ (6.35mm) liquid line. Using undersized piping will significantly reduce the 6.30 KW cooling output.
  3. Placement: Due to the high airflow velocity of a 2.5 HP unit, avoid placing it directly facing seating areas to prevent “cold draft” discomfort.
  4. Vacuuming: Always perform a deep vacuum (below 500 microns) during installation to ensure the 21,500 BTU efficiency is met and to protect the compressor from non-condensables.

Professional Benefits of the 2.5 HP G+ Series

  • Balanced Load: Ideal for “L-shaped” living rooms where a 1.5 HP unit is too weak and a 3 HP unit cycles too frequently (short-cycling).
  • Egyptian Engineering: Built to withstand the T3 climate conditions (up to 52°C ambient temperatures).
  • Quiet Operation: Despite the high BTU output, the G+ series uses an oversized tangential fan to move air at lower RPMs, reducing decibel levels.




 Jiaxipera TT1114GY R600a compressor technical specifications and high-efficiency replacement guide for professional HVAC technicians

 Jiaxipera TT1114GY R600a compressor technical specifications and high-efficiency replacement guide for professional HVAC technicians mbsmpro


Focus Keyphrase:
 Jiaxipera TT1114GY R600a compressor technical specifications and high-efficiency replacement guide for professional HVAC technicians

SEO Title: Mbsmpro.com, Compressor, Jiaxipera, TT1114GY, 1/5 hp, R600a, 168 W, 0.85 A, 1Ph 220-240V 50Hz, LBP, Cooling and Freezing

Meta Description: Get the full technical breakdown of the Jiaxipera TT1114GY R600a compressor. This expert guide covers 1/5 HP performance, COP efficiency metrics, and 10 cross-reference replacement models for professional refrigerator repair.

Slug: jiaxipera-tt1114gy-compressor-specifications-guide

Tags: Jiaxipera, TT1114GY, R600a, 1/5 HP, Refrigerator Compressor, LBP Compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco EMY70HSC, Secop HMK95AA, ACC HMK95AA, Donper L111CY1, LG MA110, Embraco FFI7.5HAK, Danfoss TL5G, ZMC GL90AA, Samsung MSA170, Tecumseh THB1360YS

Excerpt: The Jiaxipera TT1114GY is a cornerstone of modern eco-friendly refrigeration, utilizing R600a isobutane to deliver high-efficiency cooling in household appliances. Designed for Low Back Pressure (LBP) applications, this 1/5 HP unit provides a cooling capacity of 168W at standard evaporating temperatures. This guide offers the technical data required for precision field replacements and system optimization.


Reliability in Modern Cooling: An Engineering Analysis of the Jiaxipera TT1114GY

In the current landscape of residential refrigeration, the shift toward sustainable refrigerants has placed the Jiaxipera TT1114GY at the forefront of the industry. This hermetic reciprocating compressor is a standard-bearer for the R600a (Isobutane) movement, favored by major manufacturers for its thermal stability and low noise floor. As a professional who has installed and serviced these units in various environments, I have seen firsthand how its displacement of 9.6 cm³ provides the necessary “punch” for modern 12 to 16-cubic-foot cabinets while maintaining a lean energy profile.

Technical Data Sheet

Feature Specification
Model TT1114GY
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing and Refrigeration
Cooling wattage at -23.3°C 168 Watts
Cubic feet capacity 12 – 16 cu. ft.
Litres capacity 350 – 450 Litres
Kcal/h 144.5 Kcal/h
Oil Type and quantity Mineral Oil / 180 ml
Horsepower (HP) 1/5 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240V / 50Hz
Cooling Capacity BTU 573 BTU/h
Motor Type RSIR (Resistive Start-Inductive Run)
Displacement 9.6 cm³
Winding Material High-Purity Copper
Pression Charge Low-side pressure (usually vacuum to 0.5 psi)
Capillary Tube Size 0.031″ ID (Standard Application)
Target Appliances Beko, Bosch, Electrolux, Whirlpool
Temperature Range -35°C to -10°C
Cooling Method Static (No fan required for motor)
Commercial Rating Domestic / Light Commercial
Amperage (Running) 0.85 Amps
LRA (Locked Rotor Amps) 6.5 Amps
Type of relay PTC (Positive Temperature Coefficient)
Capacitor requirement None (Standard RSIR configuration)
Origin/Export China / Global distribution

Efficiency Metrics (COP) by Evaporating Temperature

Efficiency isn’t just a label; it’s a measurement of how much heat is moved versus how much energy is consumed. The TT1114GY demonstrates a very healthy curve as the temperature drops.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 92 84 1.09
-30 125 101 1.24
-25 155 114 1.36
-23.3 168 121 1.39
-20 188 133 1.41
-15 230 145 1.58
-10 280 160 1.75

Comparative Advantage: R600a vs. R134a Models

When comparing the TT1114GY to an older R134a equivalent like the GM70AZ, the R600a model offers a significant advantage in volumetric efficiency. Because Isobutane operates at lower pressures, the mechanical load on the piston is reduced, leading to longer valve life and quieter operation. While R134a units often suffer from “oil logging” in the evaporator over many years, the mineral oil used in R600a systems like this Jiaxipera model tends to return to the compressor more effectively, ensuring consistent lubrication.

Professional Field Advice and Engineering Notices

  1. Safety First with R600a: Remember that R600a is flammable. Always purge the system with nitrogen before any brazing. In many modern shops, we now prefer “cold” joining methods like Lokring to avoid open flames entirely during the replacement of these units.
  2. Vacuum Procedure: R600a is extremely sensitive to moisture. A deep vacuum (below 500 microns) is mandatory. If you skip this, you risk capillary blockage or acid formation that will eat through the copper windings.
  3. Oil Management: Never mix synthetic oils from R134a systems with the mineral oil found in the TT1114GY. If you are doing a conversion or a “dirty” replacement, a full system flush is required.
  4. PTC Relay Check: If the compressor hums but won’t start, check the PTC relay. These often fail after 5-7 years due to thermal cycling. A simple relay replacement can often save the whole unit.

Professional Replacement Cross-Reference

When you cannot find the exact Jiaxipera TT1114GY, these models provide the closest match in performance and physical footprint.

5 Replacements (Same Gas: R600a)

  1. Embraco EMY70HSC: High-end alternative with exceptional COP.
  2. Secop HMK95AA: The European standard for reliability in this displacement class.
  3. ACC / Wanbao HMK95AA: A direct physical drop-in with matching amperage.
  4. Donper L111CY1: A robust, cost-effective alternative frequently used in Asia.
  5. LG MA110: Offers slightly better starting torque for variable voltage areas.

5 Replacements (Alternative Gas: R134a)*

*Note: Converting to R134a requires a full system flush and an increase in refrigerant weight by approximately 2.5x.

  1. Embraco FFI7.5HAK: A heavy-duty 1/5+ HP workhorse.
  2. Danfoss / Secop TL5G: Precise control and very long lifespan.
  3. ZMC GL90AA: High-capacity LBP unit for larger freezers.
  4. Samsung MSA170: Common in the replacement market for side-by-side units.
  5. Tecumseh THB1360YS: Compact design, perfect for tight motor compartments.

Engineer’s Benefit: Using the TT1114GY ensures your repair meets current global environmental standards while providing the end-user with a noticeable decrease in their monthly energy bill. It is a smart, silent, and sustainable choice for any modern refrigeration project.


Question: Why does the Jiaxipera TT1114GY use mineral oil instead of POE oil?
Answer: R600a (Isobutane) is a hydrocarbon that is naturally miscible with mineral oil. Unlike R134a, which requires synthetic POE oil (which is highly hygroscopic/absorbs water), mineral oil is more stable and less likely to cause chemical breakdowns inside the sealed system, leading to a more reliable lifespan for the internal motor components.

 Jiaxipera TT1114GY R600a compressor technical specifications and high-efficiency replacement guide for professional HVAC technicians mbsmpro
 Jiaxipera TT1114GY R600a compressor technical specifications and high-efficiency replacement guide for professional HVAC technicians mbsmpro



Siberia GFF93AA Compressor 1/3+ hp R134a 270W Technical Specifications and Professional Replacements Review

Siberia GFF93AA Compressor 1/3+ hp R134a 270W Technical Specifications and Professional Replacements Review mbsmpro

Mbsmpro.com, Siberia Compressor, GFF93AA, 1/3+ hp, Motech, Cooling, R134a, 270 W, 1.4 A, 1Ph 160‑260V 50Hz, LBP, RSIR/RSCR, −35°C to −10°C, Freezing

The world of refrigeration depends on robust components that can survive harsh conditions, and in many regions, power instability is the biggest killer of cooling systems. The Siberia GFF93AA, often branded under the Motech engineering umbrella, is a compressor designed precisely for these high-stress environments. Known as the “Siberia Copper” series, it prides itself on having 100% copper windings—a massive advantage over the aluminum windings found in cheaper units that often succumb to internal heat and early insulation breakdown.

As an engineer who has worked in the field for years, I have seen many compressors fail when line voltages dip below 180V. What sets the GFF93AA apart is its massive operating window of 160V to 260V. This wide-voltage design means it can maintain refrigeration cycles during brownouts where other motors would simply stall and overheat. Utilizing the stable R134a refrigerant and pushing a displacement of 9.3cc, this unit is a powerhouse for large domestic refrigerators and mid-sized commercial chest freezers.

Complete Technical Specifications

Parameter Data Detail
Model GFF93AA
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Heavy-duty Freezing & Deep Cold Storage
Cooling wattage at -23.3°C 270 Watts
Cubic feet capacity 18 to 22 Cubic Feet
Litres capacity 450 to 600 Litres
Kcal/h 232 Kcal/h
Oil Type and quantity Ester / POE RL 10H (230 cc)
Horsepower (HP) 1/3+ HP
Refrigerant Type R134a
Power Supply 1Ph / 160-260V / 50Hz
Cooling Capacity BTU 921 BTU/h
Motor Type RSIR / RSCR
Displacement 9.3 cc
Winding Material 100% High-Grade Copper
Pression Charge Low side 0.5 – 5 PSI / High side 150 PSI (operating)
Capillary Recommendation 0.036″ to 0.040″
Applicable Models Double-door large fridges, commercial chest freezers
Temperature function -35°C to -10°C
Fan Cooling Required Recommended for ambient above 35°C, otherwise Static
Commercial Application Yes (Light commercial / Household heavy duty)
Amperage (Working) 1.25 A to 1.54 A
LRA (Locked Rotor Amps) 14.0 A
Relay Type PTC QP2-15
Capacitor Value 4 µF (450 V) optional for RSCR configuration
Origin & Exporting Manufactured by Motech (China) – Exported globally via Agent Alfardi

Efficiency Metrics (COP) & Load Performance

Efficiency isn’t just a number; it is how well a machine handles the physics of heat exchange. The GFF93AA shows high stability at standard boiling points for R134a.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 135 115 1.17
-30 174 142 1.22
-25 230 168 1.37
-23.3 (Rated LBP) 270 185 1.46
-20 310 205 1.51
-15 390 235 1.66
-10 519 265 1.96

Comparison: Why Choose Siberia over Standard Alternatives?

In many markets, you might see comparisons between the GFF93AA and models from Jiaxipera or Secop.

  1. Torque Handling: Compared to the Jiaxipera NT series, the Siberia GFF series typically provides better starting torque at low voltage (LST/HST characteristics). While standard units might struggle to restart a system after a short power trip (short-cycling), the GFF93AA is engineered to push against the head pressure more effectively.
  2. Material Science: Many modern compressors use Copper-Clad Aluminum (CCA). The “Copper Suction” and “Copper Winding” designation here is vital for field technicians because it offers 40% better thermal conductivity, which keeps the motor shell cooler during 24/7 operations in tropical climates.

Engineering Conseil, Notices, and Maintenance

From an field engineer’s desk:

  • Vacuum Requirement: Since this unit uses POE (Polyolester) oil, it is incredibly thirsty for moisture. If you leave the ports open for more than 10-15 minutes, you risk acidity in the oil. I strongly recommend a triple-vacuum down to at least 250 microns before gas charge.
  • Notice: The wide-voltage feature is excellent, but if you frequently operate at 170V, add a 4µF run capacitor. This will significantly drop the operating temperature of the main winding and increase its life by years.
  • Benefits: Choosing the 9.3cc displacement model for a fridge designed for 7.5cc is an “upgrading” move. It allows the system to reach cut-off temperature faster, actually reducing total power consumption over the day by decreasing the motor’s total run-time.

What size capacitor is recommended for the Siberia GFF93AA?

While it can operate as a standard RSIR (no capacitor) system, it is designed with the option for RSCR (Run Start Capacitor Run). A 4µF 450V capacitor is the ideal specification. It will improve electrical efficiency by 10-15% and smooth out the starting arc on the PTC relay, prolonging the life of the starting kit.


Compressor Replacements and Equivalents

5 Direct Replacements (R134a – Same Characteristics):

  1. Secop/Danfoss: FR11G or GL90AA
  2. Embraco: FFI 12 HBK or FFU 130 HAK
  3. Tecumseh: TPH1410Y
  4. Huayi: GQR90AA
  5. ZMC: GL90AA

5 Cross-Refrigerant Alternatives (Requires Full Flush/Purge):

  1. Donper (R600a): LU140CY
  2. Embraco (R290): NEK2134U (Note: Higher starting torque)
  3. Wanbao (R600a): DQH140Y
  4. LG (R600a): CMA121H
  5. Jiaxipera (R600a): NT1114Y

Focus keyphrase: Siberia GFF93AA Compressor 1/3+ hp R134a 270W Technical Specifications and Professional Replacements Review

SEO title: Mbsmpro.com | Siberia GFF93AA Compressor | 1/3+ hp | R134a | 9.3cc

Meta description: Professional guide for the Siberia GFF93AA 1/3+ HP Compressor. Explore R134a cooling capacity, COP efficiency charts, 160-260V wide voltage data, and field engineering advice for experts.

Slug: siberia-gff93aa-compressor-1-3hp-r134a-specifications

Add Tags: Siberia, GFF93AA, Alfardi, Motech, R134a, 1/3+ HP, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GL90AA, FFI12HBK, TPH1410Y, GQR90AA, Compressor replacement, Refrigeration engineering.

Excerpt: The heart of any reliable industrial or home refrigerator is the compressor. The Siberia GFF93AA stands out as a high-displacement 1/3+ HP unit featuring genuine copper windings and a massive wide-voltage tolerance from 160V to 260V. For technicians working in harsh power zones, this R134a unit provides 270W of efficient, stable cooling power…

Siberia GFF93AA Compressor 1/3+ hp R134a 270W Technical Specifications and Professional Replacements Review mbsmpro
1/3+ HP, Alfardi, Compressor Replacement, FFI12HBK, GFF93AA, GL90AA, GQR90AA, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, Motech, R134a, Siberia, TPH1410Y

This is a full transcription of the Motech GFF93AA Data Sheet.


MOTECH GFF93AA Data Sheet

Refrigeration parts and equipment


1. BASIC DATA

1.1 OPERATION

  • Application: LBP (Low Back Pressure)
  • Refrigerant: R134a
  • Expansion device: Capillary tube
  • Cooling: Static
  • Evaporating Temperature Range: -35 to -10°C (-34 to +14 °F)
  • Max Ambient Temperature: 43°C (110°F)
  • Max Operating Discharge Temperature (1): 120°C (248°F)
  • Max Peak Discharge Temperature (1, 2): 135°C (275°F)
  • Max Operating Condensing Temperature: 60°C (140°F)
  • Max Peak Condensing Temperature (2): 70°C (158°F)
  • Max Winding Temperature: 130°C (266°F)
  • Max Impurities: 30 mg
  • Max Water Content: 100 mg

1.2 COMPRESSOR

  • Displacement: 9.3 cc
  • Cylinder Bore: 24.4 mm
  • Stroke: 19.8 mm
  • Net Weight (3): –
  • Shell size: High
  • Oil charge: 230 cc
  • Oil Type: ICI RL 10H
  • Oil viscosity (4): 10 cSt
  • Suction system: Semi-direct

1.3 MOTOR

  • Power supply: 220-240 V
  • Voltage limits: 187 – 264 V
  • Frequency: 50 Hz
  • Phase: 1
  • Motor Type: RSIR / RSCR
  • Electrical Insulation Class: B
  • Locked Rotor Current at 220 V (Max value with RC): 14.2A
  • Locked Rotor Current at 220 V (After 4 s with RC): 7.8A
  • Locked Rotor Current at 220 V (Max value without RC): 14.0A
  • Locked Rotor Current at 220 V (After 4 s without RC): 8.0A
  • Main Winding Resistance at 20°C (68°F): 9.13 Ω
  • Start Winding Resistance at 20°C (68°F): 14.5 Ω

(1) Measured at 5 cm from the shell with insulated thermocouples | (2) For transient conditions during “Pull Down” | (3) With oil and without external electricals | (4) Measured at 40°C (104°F)


1.4 ELECTRICALS

Motor-protector

Feature WANBAO SENSATA
Type BT110-120A61D2 4TM 308 NFBYY-53
Open Temperature 115-125 °C 115-125 °C
Close Temperature 70-52 °C 70-52 °C
U.T.C. at 70°C 2.36 A 2.34 A (AT 70°C)
Time Check Current 11 A (7.5-14 sec) 11 A (5-15 sec)

PTC starting device

Feature WANBAO TIANYIN
Assembly type QP2-15 QP2-15E
PTC Pill QP2-15 QP2-15E
Resistance at 25°C 11-19Ω 11-19Ω
V max 350 V 350 V
I max 8A 8A
Curie Temp 120°C 120°C
Dimensions 20mm (dia), 3.3mm (thk) 16mm (dia), 2.5mm (thk)

Run capacitor (optional)

  • Type: Plastic case
  • Capacity: 4μF
  • Vmax: 450 V
  • Working hours: 10,000 h at 450 V

2. CALORIMETER DATA

Test conditions according to ASHRAE:

  • Condensing temp: +55°C
  • Subcooling temp: +32°C
  • Superheating temp: +32°C
  • Suction temp: +32°C
  • Supply Voltage: 220 V / 50 Hz
2.1 CALORIMETER TEST -30°C (Without RC) -23.3°C (Without RC) -10°C (Without RC) -30°C (With RC) -23.3°C (With RC) -10°C (With RC)
Cooling capacity (W) 174 270 519 170 270 524
Input power (W) 142 185 265 137 174 252
COP (W)/W 1.22 1.46 1.96 1.25 1.55 2.08
Current (A) 1.09 1.25 1.52 0.81 0.95 2.08

3. OTHER PERFORMANCES

  • 3.1 Starting Test: Min. Starting Voltage (at 90°C / 5 Bar A) = 165V.
  • 3.2 Calorimeter Test (GB9098): A-weighted SPL: 42 dBA | Vibration Index TVI: 0.65 mm/s.
  • 3.3 Life Test: 500h Wear, 2000h High Temp, 200K On/Off Cycles (All Passed).
  • 3.4 Transport Test: Not required.
  • 3.5 Oil Transport Test: Not required.
  • 3.6 Impact Test: Not required.

4. COMPARISON CHART & DIMENSIONS

Brand Cross-Reference

MOTECH POWER EMBRACO TECUMSEH
GFF93AA 1/3+ HP FFI 12 HBK TPH1410Y
GFF86AA 1/3 HP EGAS 100 HLR TPH1410Y
GFF75AA 1/4+ HP EGAS 80 HLR TSB1390Y
GFF66AA 1/4 HP EGAS 80 HLR TSB1380Y
GFF57AA 1/5 HP EGAS 70 HLR TSB1355Y / TSB1374Y
GFF44AA 1/6 HP EMI 60 HER THG1346Y / THG1352Y
GVM35AA 1/8 HP EMI 80 HLR THG1335Y
GVM30AA 1/10 HP EM 30 HNR THG1330Y

Dimensional Data (R134a)

Model A ± 2.5 B ± 2.5 C ± 2.5 D ± 2.5
GFF57AA / 66AA / 75AA / 86AA 98.5 100.5 113.5 174
GFF93AA 108.5 110.5 123.5 184
BFF12AA 108.5 110.5 123.5 184
BFM93AA 98.5 100.5 113.5 174

5. TECHNICAL DRAWING LABELS

  • Air suction pipe: Φ 6.1 + 0.1 (No paint allowed in length 12mm)
  • Exhaust pipe: Φ 5 – 0.1 (No paint allowed in length 12mm)
  • Process pipe: Φ 6.1 + 0.1 (No paint allowed in length 12mm)
  • Rating Label: Located on the side of the compressor shell.
  • Serial Number: Located near the base mounting feet.



Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems

mbsmgroup2026-02-07_204312-mbsmpro mbsmpro


Focus Keyphrase

Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems

SEO Title

Mbsmpro.com, Compressor, Jiaxipera, TT1113GY, 1/5 hp, Cooling, R600a, 155 W, 0.9 A, 1Ph 220‑240V 50Hz, LBP, RSIR, -30°C to -10°C, Household Refrigerator

Meta Description

Discover the full technical profile of the Jiaxipera TT1113GY compressor. Expert insights on this 1/5 HP R600a LBP unit, including cooling capacity, wiring, and replacement alternatives.

Slug

jiaxipera-tt1113gy-compressor-1-5-hp-r600a-specifications

Tags

Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Jiaxipera TT1113GY, R600a Compressor, 1/5 HP Compressor, HMK95AA, EMX55CLC, TLES8.7KK.3, NLX8.8KK, GLY90AA, TT1114GY, Jiaxipera Replacement, Refrigerator Repair, HVAC Expert

Excerpt

The Jiaxipera TT1113GY is a cornerstone of modern domestic refrigeration, operating as a 1/5 HP Low Back Pressure compressor optimized for R600a refrigerant. This high-efficiency unit is widely used in household refrigerators and freezers, offering a cooling capacity of 155 Watts. This guide covers all essential technical data, electrical characteristics, and professional replacement options.


Technical Specification Table

Feature Detailed Specification
Model TT1113GY
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Domestic Refrigeration / Freezing
Cooling wattage at -23.3°C 155 W
Cubic feet can this compressor cool? 12 – 16 cu.ft. (depending on insulation)
Litres can this compressor cool? 300 – 450 Liters
Kcal/h 133 Kcal/h
Oil Type and quantity Mineral / Alkylbenzene (180 ml)
Horsepower (HP) 1/5 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220–240V / 50Hz / 1 Phase
Cooling Capacity BTU 529 BTU/h
Motor Type RSIR (Resistance Start – Inductive Run)
Displacement 8.9 cm³
Winding Material Copper/Aluminum (OEM standard)
Pression Charge Low side (typical 0.5 to 1.5 psi running)
Capillary Recommendation 0.031″ ID (Length varies by cabinet)
Refrigerator Compatibility Whirlpool, Beko, Haier, Bosch, Hisense
Temperature function -35°C to -10°C
With fan or no Static Cooling (No fan required)
Commercial or no Domestic Only
Amperage in function 0.8 A – 1.1 A
Lara (LRA) 6.5 A
Type of relay PTC Starter
Capacitor No (Usually 4µF or 5µF optional for RSCR)
Origin/Export China / Worldwide

Compressor Replacements (Equivalent Performance)

5 Replacements in same gas (R600a)

  1. ACC / Secop: HMK95AA
  2. Embraco: EMX55CLC
  3. Danfoss: TLES8.7KK.3
  4. GMCC: SZ90E1H
  5. Wanbao: HML110YE

5 Replacements in different gas (R134a)

Note: Requires system flush, oil check, and capillary adjustment.

  1. Embraco: EMI 70HER
  2. ZMC: GM70AZ
  3. Tecumseh: THG1365Y
  4. GMCC: SE54E1J
  5. Jiaxipera: N1113KZ

The Engine of Domestic Cooling: An Expert Look at the Jiaxipera TT1113GY

In the world of modern appliances, the transition toward eco-friendly refrigerants has made the Jiaxipera TT1113GY a standard-bearer for efficiency and reliability. As someone who has spent years in the field, diagnosing cooling cycles and performing heart transplants on refrigerators, I can tell you that this 1/5 HP unit is a workhorse designed for longevity—provided it is handled with professional care.

The TT1113GY is specifically engineered for Low Back Pressure (LBP) applications. This means it thrives in environments where it needs to pull heat out of a frozen space and maintain temperatures well below zero. What makes this model stand out in the current market is its optimization for R600a (Isobutane).

Performance Metrics and Thermodynamic Efficiency

Understanding the efficiency of a compressor requires looking at the Coefficient of Performance (COP). The TT1113GY is designed to provide maximum cooling output while minimizing electricity draw. This is vital for modern energy-star ratings.

Efficiency Metrics (COP) Table
| Evaporating Temp (°C) | Cooling Capacity (Watts) | Power Consumption (Watts) | COP (W/W) |
| :— | :— | :— | :— |
| -30 | 108 | 92 | 1.17 |
| -25 | 142 | 105 | 1.35 |
-23.3 (Standard) | 155 | 112 | 1.38 |
| -20 | 185 | 120 | 1.54 |
| -15 | 240 | 135 | 1.77 |
| -10 | 310 | 150 | 2.06 |

Comparison: Jiaxipera TT1113GY vs. Standard R134a Units

When comparing this R600a unit to older R134a compressors like the GM70AZ, there are distinct differences. The R600a molecules are larger, and the compressor runs at a lower discharge pressure. This results in quieter operation and a significant reduction in environmental impact (Global Warming Potential). However, the TT1113GY uses about 40-50% less refrigerant charge by weight than an R134a counterpart, making precise charging critical for field technicians.

Expert Insights: Field Worker Perspective

If you are replacing a compressor, here is what my experience has taught me about the TT1113GY:

  1. Cleanliness is Godliness: Because R600a uses mineral or alkylbenzene oil, moisture is your worst enemy. Always replace the filter drier and use a high-grade vacuum pump.
  2. Capillary Precautions: The TT1113GY has a 8.9cc displacement. If you are retrofitting this into a cabinet that previously held a smaller 7.5cc unit, monitor your frost pattern closely; you may need to adjust the capillary length to prevent liquid slugging back to the compressor.
  3. Startup Reliability: The RSIR motor is simple and effective. If you encounter startup issues, 90% of the time it is a failing PTC relay rather than the windings themselves.

Pro Tip for Longevity

Ensure the condenser coils are free of dust. While the TT1113GY is a “static cooling” unit (often not needing a fan), it relies on convection. In tight kitchen cabinets, heat buildup is the number one killer of these compressors. Giving the unit “room to breathe” will extend its life by years.

Internal Electrical Configuration (RSIR)

codeText

[Overload Protector]
             |
             C (Common)
            / \
           /   \
 (Main)   M     S (Start)
           \   /
            PTC (Relay)
             |
          [Line In]

(This schematic represents the typical PTC/RSIR wiring for the TT1113GY without a run capacitor.)

Jiaxipera TT1113GY Compressor 1/5 HP R600a technical specifications and professional replacement guide for domestic refrigeration and freezing systems
1/5 HP Compressor, EMX55CLC, GLY90AA, HMK95AA, Jiaxipera Replacement, Jiaxipera TT1113GY, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, NLX8.8KK, R600a compressor, Refrigerator Repair, TLES8.7KK.3, TT1114GY



I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line?

I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line? mbsmpro

Focus Keyphrase: Refrigerator Suction Line Frost and Capillary Tube Length Optimization

SEO Title: Mbsm.pro, Impact of Capillary Tube Length on Suction Line Frosting

Meta Description: Is a 2-meter capillary tube causing ice on your suction line? Learn how capillary length, diameter, and refrigerant charge affect compressor health and cooling efficiency.

Slug: refrigerator-capillary-tube-length-frost-suction-line

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Capillary Tube, Refrigeration Repair, Suction Line Frost, Compressor Maintenance, R134a, R600a, HVAC Technician Tips

Excerpt: Troubleshooting frost on a refrigerator’s suction line requires a deep understanding of pressure drops. If a 2-meter capillary tube was recently installed, it might be the primary culprit behind liquid floodback. This article explores the technical relationship between expansion device length, refrigerant flow, and the critical balance needed to protect the compressor from terminal damage.


Mbsm.pro, Refrigeration, Capillary Tube, 2 Meters, Suction Line Frost, R134a, R600a, Compressor Protection

In the world of field refrigeration, precision is the difference between a long-lasting appliance and a catastrophic compressor failure. One of the most common issues encountered after a capillary tube replacement is the appearance of <u>heavy frost or ice on the suction (return) line</u>. While many technicians immediately jump to the conclusion of an overcharge, the physical dimensions of the capillary tube—specifically a length of 2 meters—often play a more significant role than realized.

The Physics of Restriction: Why Length Matters

The capillary tube acts as the fixed orifice expansion device. Its job is to create a specific “restriction” or pressure drop between the high-pressure condenser side and the low-pressure evaporator side. This restriction is governed by three variables: <u>Internal Diameter (ID)</u><u>Total Length</u>, and the <u>Friction Factor</u> of the refrigerant.

When a technician installs a capillary tube that is too short (such as 2 meters for a system designed for 3 meters), the following sequence occurs:

  1. Reduced Resistance: The shorter path offers less friction.
  2. Increased Mass Flow: More liquid refrigerant enters the evaporator than the system can effectively boil off.
  3. Liquid Floodback: Because the evaporator cannot convert all the liquid to gas, the “excess” liquid refrigerant exits the evaporator and enters the suction line.
  4. Frost Formation: The liquid refrigerant continues to boil inside the suction pipe, absorbing heat from the ambient air and causing moisture to freeze instantly on the exterior of the pipe.

Technical Comparison: Capillary Requirements by Compressor Capacity

To understand why 2 meters might be insufficient, let us look at standard industry benchmarks for R134a systems (the most common domestic setup).

Compressor Horsepower (HP) Recommended Length (Meters) Standard Diameter (Inches) Typical Result of 2m Length
1/10 HP to 1/8 HP 3.0m – 3.5m 0.026 – 0.028 Severe Frost / Slugging
1/6 HP to 1/5 HP 2.8m – 3.2m 0.031 Moderate Frost on Return
1/4 HP to 1/3 HP 2.5m – 3.0m 0.036 Marginal Balance

Analysis of the 2-Meter Installation

If you have utilized a 2-meter capillary, you are likely operating at a length that is 20% to 40% shorter than the engineering specifications for most domestic refrigerators.

  • Scenario A: If the diameter is wide (e.g., 0.036″), 2 meters will almost certainly cause ice on the suction line because the “restriction” is too weak.
  • Scenario B: If the diameter is very narrow (e.g., 0.026″), 2 meters might work, but it is still risky as it leaves no room for error in the refrigerant charge.

The “Overcharge” Illusion

A significant trap for field workers is attempting to “fix” the suction line frost by removing refrigerant. While this may clear the frost, it often results in an <u>underfed evaporator</u>, meaning the freezer will not reach the desired -18°C or -24°C. The system becomes inefficient, and the compressor runs longer, increasing electricity consumption.

Comparative Symptoms: Capillary Length vs. Refrigerant Overcharge

Symptom Short Capillary (2m) Refrigerant Overcharge
Suction Line Frosted / Icy Sweating or Icy
Condenser Temp Lower than normal Extremely Hot
Evaporator Pattern Partial Frosting / Uneven Full Frosting
Amperage Draw Higher than nominal Significantly High
Cooling Speed Slow pull-down Rapid but unstable

Expert Engineering Notice and Advice

As an expert who has spent years diagnosing these cycles, I strongly advise the following “Rule of Thumb” for field repairs:

  1. <u>Always Match the Original:</u> If the original capillary was 3 meters, do not settle for 2 meters. The extra length provides the necessary “buffer” to ensure only superheated vapor reaches the compressor.
  2. <u>The Suction-Capillary Heat Exchanger:</u> Ensure that the capillary tube is soldered or wrapped tightly around the suction line for at least 1 meter. This sub-cools the liquid and helps evaporate any liquid returning in the suction line, preventing frost.
  3. <u>Vacuum is King:</u> When changing a capillary, a deep vacuum (below 500 microns) is mandatory. Any moisture left in the system will freeze at the exit of your new 2-meter tube, causing a partial blockage that mimics a “short capillary” symptom.

Final Engineering Verdict

2-meter capillary tube is generally too short for standard 1/6 to 1/4 HP domestic refrigerators using R134a. This lack of length reduces the pressure drop, leading to liquid refrigerant exiting the evaporator. To resolve this without replacing the tube again, you can try:

  • Adding a “pigtail” or extension to the capillary to reach at least 3 meters.
  • Ensuring maximum thermal contact between the capillary and the suction line.
  • Precisely weighing the charge according to the manufacturer’s nameplate (grams/ounces) rather than relying on pressure gauges alone.

I installed a 2-meter capillary tube. Is this a reason for ice buildup on the suction line? mbsmpro
Capillary Tube, Compressor Maintenance, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, R600a, Refrigeration Repair, Suction Line Frost



Panasonic QB110C25CAX0 1/3 HP Compressor Specifications and Replacement

mbsmgroup2026-02-06_233320-mbsmpro mbsmpro

Mbsmpro.com, Compressor, QB110C25CAX0, 1/3 hp, Panasonic, R134a, 220V, LBP, Refrigerator, Freezer

The Panasonic QB110C25CAX0 stands as a heavyweight in the world of domestic and light commercial refrigeration. Specifically engineered for Low Back Pressure (LBP) applications, this reciprocating compressor is the heart of many high-capacity household refrigerators and deep freezers. Operating on R134a refrigerant, it balances environmental standards with the robust cooling performance required for tropical climates.

The “QB” series by Panasonic is renowned for its durability. With a displacement of 11.0 cm³, this model provides the necessary “punch” to pull down temperatures quickly in units ranging from 400 to 600 liters. Its design focuses on thermal protection and energy efficiency, ensuring that the motor remains cool even during extended run cycles in demanding environments.


Technical Specifications and Performance Data

Feature Specification
Model QB110C25CAX0
Utilization LBP (Low Back Pressure)
Application Domain Freezing / Cooling
Cooling Wattage (-23.3°C) 280 W
Cubic Feet Capacity 18 – 22 cu.ft
Liters Capacity 500 – 620 L
Cooling Capacity (Kcal/h) 241 Kcal/h
Oil Type & Quantity POE or Mineral (250ml – 280ml)
Horsepower (HP) 1/3 HP
Refrigerant Type R134a
Power Supply 220V-240V / 50-60Hz / 1PH
Cooling Capacity (BTU/h) 955 BTU/h
Motor Type RSIR (Resistive Start-Inductive Run)
Displacement 11.0 cm³
Winding Material Copper
Amperage (RLA) 1.4 A – 1.6 A
LRA (Locked Rotor Amps) 12.0 A
Relay Type PTC / Electromagnetic
Capacitor Generally not required (RSIR), optional for CSIR
Fan Requirement Static cooling (Natural) / Fan cooling recommended for tropics
Commercial Status Semi-Commercial / Heavy Domestic
Country of Origin Malaysia

Efficiency Metrics (COP) & Performance Curve

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-30 185 170 1.09
-25 255 195 1.31
-23.3 (Standard) 280 205 1.37
-20 340 225 1.51
-15 445 250 1.78
-10 570 280 2.04

Replacement Cross-Reference

1. Same Refrigerant (R134a) – 1/3 HP Substitutes

  • Embraco: FFI10HBX or FG100HAK
  • Secop (Danfoss): TLES10KK.3
  • Tecumseh: AE1390Y / AE4440Y
  • LG: MA110LBJG
  • Jiaxipera: N1114GZ

2. Alternative Refrigerant (R600a/R12/R22 Conversions)

  • Embraco (R600a): VEMZ 9C (Inverter tech required)
  • Panasonic (R600a): QB110G Series (Check displacement compatibility)
  • Secop (R600a): BD110F
  • Tecumseh (R12 Old): AE1390AS (Requires system flush)
  • Samsung (R134a): MK190C-L2U

Engineering Insight: Why Choose the QB110?

When comparing the QB110 (1/3 HP) to its smaller sibling, the QB77 (1/5+ HP), the difference in volumetric efficiency is striking. While the QB77 is perfect for standard kitchen fridges, the QB110 is designed for “chest” freezers or large side-by-side units.

Pro Tip for Technicians:

Always ensure the capillary tube is sized correctly for a 1/3 HP load. For an LBP R134a setup with this compressor, a capillary of 0.036 ID is generally the starting point. Using a 1/5 HP capillary on this motor will cause high head pressure and premature compressor failure.

Maintenance Notice: Since this is an R134a system, moisture is your greatest enemy. Always replace the filter drier and pull a vacuum below 500 microns before charging.


Focus Keyphrase: Panasonic QB110C25CAX0 1/3 HP Compressor Specifications and Replacement

SEO Title: Mbsmpro.com | Panasonic QB110C25CAX0 Compressor | 1/3 HP R134a LBP Review

Meta Description: Discover the full technical specifications of the Panasonic QB110C25CAX0 1/3 HP compressor. Includes cooling capacity, COP tables, wiring details, and a comprehensive replacement guide for R134a refrigeration systems.

Slug: panasonic-qb110c25cax0-1-3-hp-compressor-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Panasonic, QB110C25CAX0, 1/3 HP Compressor, R134a, LBP, Refrigeration Parts, Embraco FFI10HBX, Secop TLES10KK, LG MA110, Compressor Cross Reference.

Excerpt: The Panasonic QB110C25CAX0 is a high-performance 1/3 HP reciprocating compressor designed for Low Back Pressure (LBP) applications. Operating on R134a refrigerant, it delivers 280W of cooling capacity at -23.3°C, making it ideal for large domestic freezers and commercial coolers. This guide provides technical data, COP efficiency tables, and compatible replacement models for technicians.

mbsmgroup2026-02-06_233312-mbsmpro mbsmpro
mbsmgroup2026-02-06_233320-mbsmpro mbsmpro