Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide

Danfoss Secop SLV15CNK / SLV15CNK.2 — Complete Technical Review & Replacement Guide mbsmpro

What Is the Danfoss SLV15CNK?

If you’ve ever opened the back panel of a commercial chest freezer or a light commercial display case and found a compact, brushless compressor with a controller module attached to it, there’s a good chance you were looking at a Danfoss Secop SLV15CNK. This variable-speed hermetic compressor is one of the most widely deployed LBP (Low Back Pressure) units in European and international commercial refrigeration — and for good reason.

Originally built under the Danfoss brand before the compressor division was spun off as Secop GmbH in 2010, the SLV15CNK has carved out a reliable reputation across commercial food retail, light industrial cooling, and even medical cold-chain applications. The unit pictured above — serial reference 561108N4, profile 104H — is the standard 220–240V, 50/60 Hz variant using R290 (propane) refrigerant, one of the most eco-friendly natural refrigerants available today.


Complete Technical Specifications Table

Parameter Value
Model SLV15CNK / SLV15CNK.2
Utilisation (MBP/HBP/LBP) LBP only (Low Back Pressure)
Domain (Freezing/Cooling) Deep Freezing — evap. temp. –40°C to –10°C
Cooling Wattage at –23°C ~446 W (nominal at standard LBP conditions)
Cubic Feet Cooled ~7–10 ft³ (small to medium chest freezer)
Litres Cooled ~200–280 litres
Kcal/h ~383 Kcal/h
TON ~0.127 TON of refrigeration
Oil Type & Quantity Polyolester (POE) — 600 cm³
Horsepower (HP) 5/8 HP (~0.60 HP)
Refrigerant Type R290 (Propane) — max charge 150 g
Power Supply 220–240V / 1Ph / 50–60 Hz (range: 180–254V)
Cooling Capacity BTU ~1521 BTU/h (LBP nominal)
Motor Type Permanent Magnet (TRI — 3-phase inverter driven)
Displacement 15.28 cm³
Winding Material Copper (3-phase windings, resistance ~7.7 Ω at 25°C)
Pression Charge LBP / LST — max condensing temp 55°C (65°C short-term)
Capillary Approx. 3m / Ø0.31 mm (application-dependent — verify with OEM data)
Compatible Refrigerator Models AHT Deep Freezers, light commercial chest freezers, display cases, ice machines, beverage coolers
Temperature Function –40°C to –10°C evaporating; –35°C practical freezer operation
With Fan or Not Yes — F2 fan cooling required (3.0 m/s airflow on compressor & controller)
Commercial or Domestic Commercial (light commercial / food retail)
Amperage in Function Max 4.6 A
LRA (Locked Rotor Amperage) Electronic cut-off (no traditional LRA — inverter-controlled)
Type of Relay No traditional relay — uses 105N46xx Series SLV Electronic Controller
Capacitor No start/run capacitor — inverter-driven (variable speed 2000–4000 RPM)
Country of Origin & Export Manufactured in Slovakia (Secop GmbH) — exported globally: EU, UK, Middle East, North Africa, Australia, Asia

What Makes This Compressor Special?

Variable Speed Technology

Most technicians encounter fixed-speed compressors day in and day out. The SLV15CNK breaks that mold entirely. It’s a variable speed drive (VSD) compressor, meaning its speed adapts continuously between 2000 and 4000 RPM based on thermal demand. The result is dramatically reduced energy consumption during low-load periods, less mechanical wear, and quieter operation — all things that matter enormously in a commercial food retail environment where a freezer runs 24/7, 365 days a year.

R290 — The Natural Refrigerant Advantage

R290 (propane) is not new, but its adoption in commercial compressors has accelerated rapidly in recent years thanks to its near-zero Global Warming Potential (GWP = 3) compared to the synthetic alternatives it replaces. The SLV15CNK uses a maximum charge of just 150 grams, which keeps it below the safety threshold for flammable refrigerant use in occupied spaces. That tiny charge, combined with propane’s excellent thermodynamic properties, means this compressor achieves high efficiency with a very light environmental footprint.

The Controller Dependency

One detail technicians absolutely must not overlook: this compressor will not function without its dedicated SLV electronic controller (105N46xx series). The label on the unit itself clearly states “Only with SLV controller.” This is not a traditional hermetic compressor you can simply wire up to a relay and a capacitor. The controller handles speed regulation, current protection, speed monitoring, and thermal protection all in one unit. Replacing or sourcing this controller is as important as finding the compressor itself.

Fan Cooling Is Mandatory

At all ambient conditions (32°C, 38°C, and 43°C), the datasheet specifies F2 cooling — meaning fan airflow of at least 3.0 m/s directly on both the compressor body and the electronic controller unit. Attempting to run this compressor without proper forced airflow will trigger thermal protection and lead to premature failure. This is a common oversight when installers replace the compressor without checking the cabinet’s fan arrangement.


Replacement Compressors — Same Gas (R290)

When the SLV15CNK reaches end of life or fails, the most straightforward replacements use the same R290 refrigerant. Here are five proven options:

# Replacement Model Brand Notes
1 SLV15CNK.2 (104H8541) Secop/Danfoss Direct drop-in replacement — latest revision
2 SLV12CNK.2 Secop/Danfoss Slightly lower displacement, same gas and controller family
3 SLV20CNK.2 Secop/Danfoss Higher capacity option — same R290/controller platform
4 NLV14CNK Secop/Danfoss Fixed-speed variant on R290 LBP — requires relay/capacitor
5 SCM10CNX.2 Secop R290, standard hermetic, LBP — no inverter controller needed

Replacement Compressors — Different Refrigerant

If R290 is not available in your region, or if you’re retro-fitting an older system, here are five equivalents using alternative refrigerants with comparable capacity:

# Replacement Model Brand Refrigerant Notes
1 SC15G Secop/Danfoss R404A / R507A Classic LBP hermetic, no controller needed
2 NL11MF Secop/Danfoss R134a LBP/MBP, standard hermetic
3 CAJ9513Z Embraco R404A Direct LBP replacement at similar capacity
4 NEBL2134Z Embraco R600a For domestic/light LBP applications
5 MTZ32-4VM Danfoss R452A/R404A Slightly oversized but compatible for retrofits

⚠️ Important: Switching refrigerants requires changing the oil type, capillary tube, and verifying all safety certifications. Always consult the system manufacturer before cross-refrigerant replacement.


Typical Applications — Which Freezers Use This Compressor?

The SLV15CNK is the heart of many products you’ll recognize from the supermarket floor:

  • AHT Australian series chest freezers (confirmed via MBSM documentation)
  • Light commercial open-top island freezers
  • Vertical display freezer cabinets (small commercial)
  • Beverage coolers with sub-zero requirements
  • Frozen food display cases at petrol stations and convenience stores
  • Ice cream chest cabinets in retail environments

The AHT connection is particularly well-documented — AHT is a major manufacturer of commercial freezers widely deployed across European and African retail chains, and the SLV15CNK is one of their standard compressor choices.


Installation & Service Notes

A few practical points every technician should keep in mind when working with this unit:

Controller wiring: Always refer to the 105N46xx wiring diagram. Polarity and signal connections matter — the controller is not interchangeable between all SLV variants.

Refrigerant handling: R290 is flammable (Class A3). Work in ventilated areas, avoid open flames, and use an R290-certified manifold gauge set. The 150g charge limit means leaks are rare but must be taken seriously.

Oil compatibility: POE oil is mandatory with R290 in this application. Do not substitute mineral oil or alkylbenzene — POE is pre-filled at the factory at 600 cm³.

Mounting vibration: The compressor ships with rubber mounting grommets. Always re-use or replace them — running on a hard mount increases noise and mechanical fatigue.

Capillary tube: The reference capillary for AHT applications is approximately 3m / 0.31mm diameter, but always measure and verify against the original system before cutting new tubing.


Why This Compressor Matters in 2025 and Beyond

The refrigeration industry is at a turning point. Synthetic refrigerants with high GWP are being phased out under F-Gas regulations in Europe and similar legislation worldwide. The SLV15CNK — running on propane with a permanent magnet variable-speed motor — represents exactly the direction the industry is heading: natural refrigerants, intelligent speed control, and reduced energy consumption without compromising reliability.

For service technicians, understanding this platform deeply isn’t just useful today — it’s preparation for the next decade of commercial refrigeration work.




Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp

Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro

PHASE 1: SURGICAL IMAGE ANALYSIS

Feature Visible Nameplate Data
Brand Emerson Climate Technologies / Copeland
Model KCE444HAG-B332H (Family: KCE444HAG)
Serial Number GCRA-0909669
Voltage/Hz/Phase 1Ph 180-260 V AC / 230V, 50 Hz
Refrigerant R-134a
LRA (Locked Rotor Amps) 13 A
Electrical Circuit CSCR
Oil Type & Volume 10.5 oz POE (Polyolester)
Application High Temp (HBP)
Relay & OLP Relay: KARPN-4241 / OLP: KAT0072/H3 OR MRA-12309-12101
Capacitors Run: 10 µF @ 440 V AC / Start: 40-60 µF @ 230 V AC
Manufacturing Origin Mfg. By Emerson Climate Technologies (India) Limited

PHASE 3: ARTICLE STRUCTURE

SEO Metadata

  • Focus Keyphrase: KCE444HAG Compressor
  • SEO Web Title: Mbsmpro.com, Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp
  • Meta Description: Technical specs for the Copeland KCE444HAG compressor. Includes LRA, displacement, electrical data, and equivalent drop-in cross-references for field techs.
  • Slug: copeland-kce444hag-specs-replacement
  • Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, KCE444HAG, NEK6210Z, SC12G, NT1112Y, FL2088-SA, GP12TB
  • Excerpt: Field data and technical breakdown of the Emerson Copeland KCE444HAG 3/8 HP commercial refrigeration compressor, including performance charts and direct replacement options.

Field Introduction

Found this slugger in a glass-door Coca-Cola merchandiser or a heavy-duty sandwich prep table? You are looking at the Emerson Copeland KCE444HAG. This 3/8 HP unit is a cast-iron workhorse built to handle the constant door-opening abuse of commercial beverage coolers. When a shop owner relies on cold drinks to keep the lights on, this HBP (High Back Pressure) compressor does the heavy lifting. It runs smoothly on R-134a, but when it finally locks up or burns out a winding, you need the hard numbers to wire it back up or drop in a reliable match. Let’s break down the specs.


Full Nameplate Data Table

Here is exactly what is stamped on the steel:

Parameter Specification
Manufacturer Emerson Climate Technologies (Copeland)
Model KCE444HAG-B332H
Serial GCRA-0909669
Voltage 180-260 V AC (Rated 230V), 50 Hz
Phase Single Phase (1Ph)
Locked Rotor Amps (LRA) 13 A
Refrigerant R-134a
Application High Temp
Motor Type CSCR
Oil Charge 10.5 oz Polyolester (POE)
Country of Origin India

Technical Specifications Table

Knowing what the compressor is doing on the inside dictates how you size the metering device and handle the system charge.

Specification Value
Horsepower (HP) 3/8 HP
Displacement 12.05 cc
Cooling Capacity (HBP) ~3675 BTU/h / 1077 Watts
Application Type HBP / CBP (High / Commercial Back Pressure)
Operating Voltage 230V
Motor Type CSCR (Capacitor Start, Capacitor Run)
Max Continuous Current (MCC) 3.0 A
Rated Load Amps (RLA) ~2.2 A (at HBP standard conditions)

Electrical & Origin Details

Wiring up a CSCR motor means you are dealing with potential relays and dual capacitors. Don’t mix up your start and run values, or you will bake the new start winding before lunch.

  • Motor Circuit: CSCR (Capacitor Start, Capacitor Run) for high starting torque.
  • Start Capacitor: 40-60 µF @ 230 V AC (Gets the heavy rotor moving against high head pressure).
  • Run Capacitor: 10 µF @ 440 V AC (Keeps the power factor tight and the motor running cool).
  • Relay Model: KARPN-4241 (Potential Relay).
  • Overload Protector (OLP): KAT0072/H3 or MRA-12309-12101.
  • Manufactured By: Emerson Climate Technologies (India) Limited.

Efficiency Metrics Table

Here is how the KCE444HAG pulls down at varying evaporator temperatures (assuming a standard 130°F / 54.4°C condensing temp):

Evaporating Temp (°F / °C) Cooling Capacity (BTU/h) Power Input (Watts) Amp Draw
45°F / 7.2°C (HBP) 3675 475 2.2
20°F / -6.7°C (CBP) 1880 339 1.64
0°F / -17.8°C 1190 268 1.33

Drop-in Replacements

If you can’t source a fresh Copeland KCE444HAG from the supply house, these 3/8 HP, ~12cc, R-134a HBP models will bolt right in and keep the cabinet at temp:

  • Embraco: NEK6210Z
  • Secop / Danfoss: SC12G
  • Jiaxipera: NT1112Y
  • GMCC: FL2088-SA
  • Cubigel / Huayi: GP12TB
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro
Compressor, KCE444HAG, 3/8 HP, Copeland, R-134a, 1077 W, 2.2 A, 230V, HBP, CSCR, High Temp mbsmpro



Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure

Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure mbsmpro

  • Focus Keyphrase: Embraco EMI 62UHR Compressor
  • SEO Web Title: Mbsmpro.com, Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure
  • Meta Description: Full technical specs for the Embraco EMI 62UHR compressor. Includes 127V 60Hz data, LRA, displacement, and compatible replacement models for Consul refrigerators.
  • Slug: embraco-emi-62uhr-specs-replacement-guide
  • Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, EMI 62UHR, EMI62UHR, CRD34BBANA, FF7.5HBK, EMT6170Z, GPY12AF, NEK6170Z
  • Excerpt: Technical breakdown of the Embraco EMI 62UHR (1/5 HP) used in Consul CRD34BBANA refrigerators. Specs cover R134a usage, 127V/60Hz electricals, and cross-reference units.

Field Introduction

You’ll usually run into this Embraco EMI 62UHR tucked into the back of a Consul or Brastemp domestic refrigerator—specifically the CRD34B series popular in the Latin American market. It’s a workhorse for mid-sized “combinado” units (fridge/freezer combos). This specific unit is pulled from a system running on 127V at 60Hz, common in Brazil and parts of North America. If you see that rust on the shell in the photo, check the base plate and vibration isolators; these units vibrate a fair bit when the rubber gets hard, which can lead to hairline fractures in the discharge line.


Full Nameplate Data Table

Detail Specification
Brand Embraco
Model EMI 62UHR
Serial Number 513307032
Voltage / Hz / Phase 115-127 V / 60 Hz / 1 Phase
Refrigerant R134a
Current (RLA) 2.0 A
Power (Input) 140 W
Manufacturing Origin Brazil (Multibras S.A.)
Appliance Model Consul CRD34BBANA
Charge Amount 110 g (from appliance label)

Technical Specifications Table

Property Value
Application MBP (Medium Back Pressure)
Horsepower (HP) 1/5 HP
Cooling Capacity ~630 BTU/h (approx. 185 W)
Displacement 5.20 cc
Motor Type RSIR (Resistance Start – Inductive Run)
Evaporating Temp Range -10°C to +10°C (14°F to 50°F)
Expansion Device Capillary Tube

Electrical & Origin Details

  • Motor Protector: Internal/External overload protector (T0490/G6).
  • Relay Type: PTC (Positive Temperature Coefficient).
  • Start Capacitor: Not required for RSIR (Standard configuration).
  • Manufacturing Country: Brazil.
  • Appliance Data: This unit is paired with the CRD34B Consul refrigerator, which features a total volume of 322L and a freezing capacity of 3.6kg every 24 hours.

Efficiency Metrics Table

Evaporating Temp (°C) Cooling Capacity (W) Power Consumption (W) Efficiency (W/W)
-10 185 140 1.32
-5 225 152 1.48
0 275 165 1.67
+5 330 180 1.83

Drop-in Replacements

If you can’t find the exact EMI 62UHR, these units will bolt up and handle the load, provided you match the 127V/60Hz requirement:

  • Embraco: FF7.5HBK (Heavy-duty alternative)
  • Embraco: EMT6170Z (Modern high-efficiency swap)
  • Secop / Danfoss: TLES5.7FT.3
  • Tecumseh: THB1355YXA
  • Jiaxipera: GPY12AF
  • GMCC: SZ59C1H
Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure mbsmpro
Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure mbsmpro
Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure mbsmpro
Compressor, EMI 62UHR, 1/5 HP, Embraco, R134a, 140 W, 2.0 A, 127V, MBP, RSIR, Medium Back Pressure mbsmpro



Embraco EGAS 100HLR Guide: Technical Specs & Field Replacements

Embraco EGAS 100HLR Guide: Technical Specs & Field Replacements mbsmpro

  • Focus Keyphrase: Embraco EGAS 100HLR Compressor Specs
  • SEO Title: Embraco EGAS 100HLR Guide: Technical Specs & Field Replacements
  • Meta Description: Get the breakdown on the Embraco EGAS 100HLR. We cover LRA, R134a specs, displacement, and the best drop-in replacements for this common LBP workhorse.
  • Slug: embraco-egas-100hlr-compressor-specs-replacements
  • Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco, EGAS 100HLR, R134a, LBP, Compressor Replacement, HVAC, Refrigeration Repair, 220-240V.
  • Excerpt: The Embraco EGAS 100HLR is a staple in domestic refrigeration. This guide provides the raw technical data and equivalent models for fast field swaps.

Field Introduction

You’ll run into the Embraco EGAS 100HLR mostly in standard household refrigerators and large upright freezers. It’s a reliable Low Back Pressure (LBP) unit built for R134a. When these fail, it’s usually a hard start issue or a grounded winding after years of heat cycles. It’s a straightforward swap, but you need to match the displacement and LRA to keep the system balanced.


Technical Specifications Table

Feature Details
Model EGAS 100HLR
Brand Embraco
Refrigerant R134a
Application LBP (Low Back Pressure)
Voltage/Frequency 220-240V / 50-60Hz
Phase 1 PH (Single Phase)
LRA (Locked Rotor Amps) 16.9 A (at 60Hz) / 16.0 A (at 50Hz)
Horsepower (HP) ~1/3 HP
Displacement 7.95 cm³
Motor Type RSIR/CSIR (Depending on starter kit)
Cooling Capacity ~235 – 280 Watts (ASHRAE LBP)
Protection Thermally Protected

Electrical & Origin Details

  • Relay Type: Uses a standard PTC or a Current Relay if configured for CSIR.
  • Capacitor Needs: Usually runs fine without a run capacitor (RSIR), but a start capacitor (approx. 60-80 µF) is often added for high-torque starts.
  • Manufacturing Origin: Joinville, Brazil (as seen on the nameplate).

Efficiency Metrics (ASHRAE LBP)

Performance changes based on your evaporator temperature. Here’s what to expect:

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 130 145 0.90
-30 185 170 1.09
-25 240 195 1.23
-23.3 265 205 1.29
-20 310 225 1.38
-15 390 255 1.53

Drop-in Replacements

If you can’t source the exact EGAS 100HLR, these models match the displacement and cooling curve for R134a systems:

  • Embraco: FFI 10HBX or EGYS 100HLP (High Efficiency version).
  • Secop/Danfoss: TLES10KK.3 or NLE10KK (Ensure R134a compatibility).
  • Jiaxipera: N1114GZ.
  • GMCC: SZ90E1H.
  • Huayi: HYE96YG.
  • Tecumseh: THG1374YS.

Field Note: Always replace the filter drier and pull a deep vacuum to 500 microns before charging R134a. This model uses POE oil; don’t leave the system open to the atmosphere for longer than necessary.

Embraco EGAS 100HLR Compressor Specs mbsmpro
Embraco EGAS 100HLR Compressor Specs mbsmpro



LG NS24LAEG Compressor Specs and Replacements

LG NS24LAEG Compressor Specs and Replacements mbsmpro

  • Brand: LG
  • Model: NS24LAEG
  • Voltage/Frequency: 220-240V ~ 50Hz
  • Phase: 1PH
  • Protection: Thermally Protected
  • Origin: LG Electronics Inc. / Made in Korea

SEO Metadata

  • Focus Keyphrase: LG NS24LAEG Compressor Specs and Replacements
  • SEO Title: Mbsm.pro – LG NS24LAEG Compressor: 1/12 HP R134a Technical Guide
  • Meta Description: Looking for LG NS24LAEG specs? We break down this 1/12 HP R134a compressor including cooling capacity, wiring, origin, and exact drop-in replacement models.
  • Slug: lg-ns24laeg-compressor-r134a-specs
  • Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, LG Compressor, NS24LAEG, R134a, LBP, 1/12 HP, RSIR, HVAC Repair.
  • Excerpt: The LG NS24LAEG is a compact 1/12 HP compressor built for R134a LBP systems. You’ll usually find this unit running small water dispensers and mini-fridges. Here is the raw technical data and field replacements.

Field Introduction

You see the LG NS24LAEG pulled out of small residential appliances like water dispensers, dorm fridges, and under-counter ice boxes. It is a strictly Low Back Pressure (LBP) pump running R134a. Rated right around 1/12 HP, it has a tiny 2.42 cc displacement. It is not built to handle heavy commercial loads. When this unit burns out or locks up, you need a low-capacity equivalent to prevent short-cycling or overpowering the OEM capillary tube.

Technical Specifications Table

Feature Details
Model NS24LAEG
Brand LG
Application LBP (Low Back Pressure)
Refrigerant R134a
Displacement 2.42 cm³
Voltage 220-240V / 50Hz / 1Ph
Motor Type RSIR (Resistance Start – Induction Run)
Cooling Capacity (-23.3°C) 44 W / 150 BTU/h
Horsepower (HP) ~1/12 HP
Input Power 76 W

Electrical & Origin Details

  • Relay Type: PTC Starting Relay (specifically the P220MC matching the RSIR motor).
  • Capacitor Needs: None. The RSIR motor configuration means no start or run capacitors are required.
  • Overload Protector: 4TM117SFB external thermal overload.
  • Manufacturing Origin: Manufactured by LG Electronics Inc. in Korea.

Efficiency Metrics Table

Performance drops hard if you push an LBP pump outside its temperature envelope. Here is how the NS24LAEG runs across the standard low-temp spectrum.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 22 52 0.42
-30 31 61 0.50
-25 41 72 0.56
-23.3 44 76 0.58
-20 55 83 0.66
-15 73 94 0.77

Drop-in Replacements

When you can’t source the exact LG NS24LAEG, you need a 1/12 HP, R134a LBP compressor with a displacement around 2.4 to 3.0 cc. Here are solid field equivalents:

  • Embraco EMY20CLC: A rock-solid 1/12 HP drop-in. Matches the LBP footprint and capillary demands perfectly.
  • Secop / Danfoss TL3G: Slightly larger displacement (3.13 cc) but throttles well for small fridges and dispensers.
  • Jiaxipera T1040Y: Common Chinese market equivalent. Easy to pipe in and matches the RSIR electrical setup.
  • Huayi HYB35YG: Standard replacement. Pulls similar wattage and fits exactly the same base plate.
  • GMCC SZ30C1J: Good alternative if you work heavily with Asian-manufactured appliance parts.
LG NS24LAEG Compressor Specs and Replacements mbsmpro
LG NS24LAEG Compressor Specs and Replacements mbsmpro