Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro

Focus Keyphrase

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers

SEO Title

Mbsmpro.com, Compressor, ETK130L, 1/4 hp, Donper, Cooling, R600a, 220 W, 1.1 A, 1Ph 220‑240V 50Hz, LBP, RSCR, −35°C to −10°C, Freezing

Meta Description

Technical deep-dive into the Donper ETK130L compressor. Includes 1/4 HP R600a performance charts, cooling capacity, electrical schematics, and expert cross-reference guides.

Slug

donper-etk130l-compressor-r600a-1-4hp-specs-replacement

Excerpt

The Donper ETK130L compressor is a high-efficiency 1/4 HP unit designed for low back pressure applications using R600a refrigerant. This article provides a comprehensive technical breakdown, including cooling capacity, electrical schematics, and cross-reference replacements. Ideal for technicians and engineers seeking precise data for maintenance and system optimization in domestic and light commercial refrigeration.


Donper ETK130L: The Engineering Standard for Modern R600a Refrigeration

In the evolving landscape of domestic cooling, the Donper ETK130L stands as a testament to efficient, low-impact refrigeration. As a seasoned technician who has spent years in the field, I can tell you that transitioning to R600a (Isobutane) systems required a shift in mindset. The ETK130L is a high-performance 1/4 HP hermetic reciprocating compressor that has become a staple in large-capacity domestic freezers and side-by-side refrigerators.

This unit isn’t just about moving gas; it’s about thermodynamic precision. Engineered by the Huangshi Dongbei Electrical Corp, it targets Low Back Pressure (LBP) environments, ensuring that even when the mercury rises outside, the internal temperatures stay locked in the deep-freeze zone.


Comprehensive Technical Data

Feature Specification
Model ETK130L
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Cold Storage
Cooling wattage at -23.3°C 220 Watts
Cubic feet can this compressor cool? 16 to 20 Cubic Feet
Litres can this compressor cool? 450 to 550 Liters
Kcal/h 189 Kcal/h
Oil Type and quantity Mineral / POE – 180ml
Horsepower (HP) 1/4 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240V / 50Hz / 1Ph
Cooling Capacity BTU 750 BTU/h
Motor Type RSCR (Resistive Start – Capacitive Run)
Displacement 13.0 cm³
Winding Material High-Grade Copper
Pression Charge Low Pressure (Suction)
Capillary 0.031″ / 0.8mm (Approx. 3 meters)
Model Fridge Compatibility Large Chest Freezers, Samsung/LG Style Fridges
Temperature function -35°C to -10°C
With fan or no Generally Static (Forced air optional)
Commercial or no Domestic / Light Commercial
Amperage in function 1.1 A
LRA (Locked Rotor Amps) 8.2 A
Type of relay PTC (Positive Temperature Coefficient)
Capacitor or no and valeur Run Capacitor: 4µF or 5µF
Country of origin China

Efficiency Metrics & Thermodynamic Performance (COP)

Understanding the Coefficient of Performance (COP) is critical for any engineer looking to optimize energy star ratings. Below is the performance curve for the ETK130L at various evaporating stages.صورة vapor compression refrigeration cycle diagram

Shutterstock

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 128 118 1.08
-30 165 135 1.22
-23.3 (Standard) 220 155 1.42
-20 258 168 1.54
-15 315 185 1.70
-10 385 205 1.88
0 540 (N/A for LBP)
4
10

Electrical Schematic: RSCR Configuration

The ETK130L typically utilizes an RSCR (Resistive Start – Capacitive Run) setup to maximize energy savings. Here is the logical wiring layout:

  1. Common (C): Connects to the Overload Protector (OLP).
  2. Main/Run (R): Connects directly to the Neutral line.
  3. Start (S): Connects through the PTC Relay.
  4. Run Capacitor: Wired across the Start and Run terminals of the PTC relay to maintain current phase alignment during operation, significantly lowering the running amperage.

Field Note: If you find the compressor “clicking” without starting, check the 4µF capacitor. A failed capacitor in an RSCR system often prevents the motor from overcoming its initial torque requirements.


Comparative Analysis: R600a vs. R134a Equivalents

When comparing the ETK130L (R600a) to an older R134a unit like the GP12, several differences emerge:

  • Operating Pressure: The ETK130L operates under a vacuum on the suction side or at very low positive pressure. R134a units run at much higher pressures.
  • Lubrication: R600a is highly miscible with mineral oil, whereas R134a strictly requires synthetic POE/PAG oils.
  • Energy Consumption: The ETK130L generally consumes 10-15% less electricity than its R134a counterpart for the same cooling output.

Cross-Reference Replacement Guide

5 Replacements (Same Gas: R600a)

  1. Secop (Danfoss): NLE13KK.4
  2. Embraco: EMX70CLC
  3. Jiaxipera: NT1114Y
  4. Huayi: HYB130MHU
  5. LG: CMA121LHEG

5 Replacements (Alternative Gas: R134a)

Note: Using these requires a complete system flush and oil change.

  1. Embraco: FFI10HAK (1/3 HP to match R600a displacement)
  2. Secop: TLES10KK.3
  3. ZMC: GL90AA
  4. Donper: GP12TG
  5. Tecumseh: THB1390YS

Engineering Advice & Maintenance Notice

  • Safety: R600a is flammable. Never use a standard piercing valve for long-term service. Brazing should only be performed after ensuring the system is completely purged with Nitrogen.
  • Vacuum Depth: Aim for 200 microns. Moisture is the enemy of the long-term reliability of the internal valves.
  • Charging: Always charge by weight using a digital scale. R600a systems are extremely sensitive; even an overcharge of 5 grams can cause liquid slugging.

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, ETK130L, R600a, NLE13KK, EMX70CLC, NT1114Y, HYB130MHU, CMA121LHEG, FFI10HAK, TLES10KK, GL90AA, GP12TG, THB1390YS, Compressor Replacement, 1/4 HP Compressor, LBP Refrigeration.

Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro
Donper ETK130L Compressor 1/4 HP R600a LBP Specifications and Professional Technical Guide for Refrigeration Engineers mbsmpro



Jiaxipera VMH1111Y Inverter Compressor R600a

Jiaxipera VMH1111Y Inverter Compressor R600a mbsmpro

Mbsmpro.com, Compressor, Jiaxipera, VMH1111Y, 1/5 hp, Inverter, Cooling, R600a, 156 W, 22-75Hz, 1Ph 230V, LBP, Variable Speed, -35°C to -15°C


Technical Specifications Table

Feature Details
Model VMH1111Y
Utilisation LBP (Low Back Pressure)
Domaine Domestic Freezing / Deep Cooling
Cooling Wattage at -23.3°C 156 W (at maximum frequency)
Cubic feet capacity 18 – 22 cu.ft. (depending on insulation)
Litres capacity 500 – 600 Liters
Kcal/h 134 Kcal/h
Oil Type and Quantity POE (Polyolester) / 220ml
Horsepower (HP) 1/5 HP (Equivalent)
Refrigerant Type R600a (Isobutane)
Power Supply 230V ~ 22-75Hz (Inverter)
Cooling Capacity BTU 532 BTU/h
Motor Type BLDC (Brushless DC Motor)
Displacement 11.1 $cm^3$
Winding Material High-Grade Copper
Pression Charge 1.5 – 2.5 Bar (Low Side)
Capillary Recommendation 0.031″ (0.78mm) x 3.0 meters
Compatible Refrigerators Sharp, Toshiba, Panasonic High-End Inverter Models
Temperature Function -35°C to -15°C
Fan Requirement No (Static cooling, but fan improves efficiency)
Commercial Application No (Domestic Premium)
Amperage in Function 0.8A to 1.4A (Variable)
L.R.A (Locked Rotor Amps) 4.5A (Electronic limited)
Type of Relay Inverter Controller Module (Electronic Board)
Capacitor Included Not applicable (Inverter controlled)
Country of Origin China (Jiaxipera) / Exported Globally

Compressor Replacement Guide

5 Replacements (Same Gas: R600a)

  1. Embraco: FMXA9C
  2. Secop: FMXA6C
  3. LG: BMA098NHMV
  4. Panasonic: DH45V11D
  5. Samsung: NC4V121

5 Replacements (Other Gas: R134a – Requires system flush and oil change)

  1. Embraco: FFI 7.5HAK (Fixed speed conversion required)
  2. Tecumseh: THG1365YS
  3. GMCC: PZ70H1Z
  4. Secop: TLES7.5KK.3
  5. ZMC: GL70AA

Efficiency Metrics (COP) Performance Data

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 82 68 1.20
-30 110 80 1.37
-25 142 92 1.54
-23.3 156 98 1.59
-20 185 108 1.71
-15 230 125 1.84
-10 285 145 1.96

Mastering Efficiency: The Jiaxipera VMH1111Y Inverter Compressor

The modern refrigeration landscape is shifting away from the loud, “clunky” on-off cycles of the past. As a field technician who has worked on hundreds of high-end Sharp and Toshiba units, I can tell you that the Jiaxipera VMH1111Y represents the gold standard of variable-speed technology. This isn’t just a motor; it’s a precision instrument designed for energy savings and food preservation.

Why Variable Speed Matters

Unlike standard compressors that run at 100% or 0%, this BLDC motor operates between 22Hz and 75Hz. When the fridge door stays closed, the compressor slows down to a whisper, consuming barely more electricity than a lightbulb. When you load groceries, it ramps up to 75Hz to pull the temperature down instantly.

Engineering Comparison: VMH1111Y vs. Standard Fixed Speed

Feature Jiaxipera VMH1111Y (Inverter) Standard 1/5 HP (Fixed Speed)
Energy Consumption Up to 40% lower High (Cycle start-up peaks)
Noise Level 35-38 dB 42-45 dB
Temperature Swing ±0.5°C ±2.0°C
Refrigerant R600a (Eco-friendly) R134a (Older models)

Expert Field Advice

If you are a technician replacing this unit, remember: You cannot bypass the inverter board. Testing this compressor requires an inverter tester or checking the 3-pin UVW resistance (it should be balanced). Because it uses R600a (Isobutane), safety is paramount. Always use a vacuum pump and avoid open flames—iso-butane is flammable, and professional “no-flame” joining techniques (like Lokring) or careful brazing with proper ventilation are mandatory.

Technician’s Tip: Check the inverter controller first. Often, the compressor is fine, but the electronic module on the side of the unit has failed due to power surges.


Focus Keyphrase: Jiaxipera VMH1111Y Inverter Compressor R600a

SEO Title: Mbsmpro.com | Jiaxipera VMH1111Y Compressor | 1/5 HP Inverter R600a

Meta Description: Discover the technical specs of the Jiaxipera VMH1111Y Inverter Compressor. Expert guide on cooling capacity, R600a performance, and pro-level replacement options for Sharp refrigerators.

Slug: jiaxipera-vmh1111y-inverter-compressor-r600a-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Jiaxipera, VMH1111Y, R600a, Inverter Compressor, Refrigerator Repair, Sharp Compressor, Embraco FMXA9C, Secop FMXA6C, 1/5 HP Compressor, BLDC Motor, HVAC Engineering.

Excerpt: The Jiaxipera VMH1111Y is a high-efficiency variable-speed inverter compressor optimized for R600a refrigerant. Operating between 22Hz and 75Hz, it offers a 1/5 HP equivalent output, making it the preferred choice for premium Sharp and Toshiba refrigerators. This guide breaks down its electrical characteristics, COP efficiency metrics, and professional field-tested replacement alternatives for modern cooling systems.

Jiaxipera VMH1111Y Inverter Compressor R600a mbsmpro
1/5 HP Compressor, BLDC Motor, Embraco FMXA9C, Inverter Compressor, Jiaxipera, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R600a, Refrigerator Repair, Secop FMXA6C, Sharp Compressor, VMH1111Y



Secop ES7FT.4 Compressor 1/5 HP R134a Technical Specifications and Replacements

Secop ES7FT.4 Compressor 1/5 HP R134a Technical Specifications and Replacements mbsmpro

Mbsmpro.com, Compressor, ES7FT.4, 1/5 hp, Secop, Cooling, R134a, 147 W, 1.1 A, 1Ph 220‑240V 50Hz, LBP, RSIR, −35°C to −10°C, Static Cooling

The Secop ES7FT.4 represents a pinnacle of energy-optimized engineering for tropical refrigeration environments. Designed specifically for low back pressure (LBP) applications, this hermetic reciprocating compressor is a reliable workhorse for household refrigerators and small commercial freezers. Operating on R134a refrigerant, it balances thermal efficiency with the robust durability required for high-ambient temperature regions.

Technical Specification Table

Attribute Details
Model ES7FT.4 (102G4707)
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Deep Cooling
Cooling Wattage at -23.3°C 147 Watts (CECOMAF)
Cubic Feet Capacity Approx. 7 – 10 cu.ft
Liters Capacity 200 – 300 Liters
Kcal/h 126 kcal/h
Oil Type & Quantity Polyolester (POE) / 180 cm³
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V / 50Hz / 1Ph
Cooling Capacity BTU 502 BTU/h
Motor Type RSIR (Resistance Start – Induction Run)
Displacement 5.70 cm³
Winding Material Copper
Pression Charge Low Pressure Side
Capillary Recommendation 0.031″ or 0.8mm (application dependent)
Appliance Type Domestic Fridge, Chest Freezer, Water Dispenser
Temperature Function -35°C to -10°C
Cooling System Static (S)
Commercial Class Semi-Commercial / Residential
Amperage (RLA) 1.1 A
LRA (Locked Rotor Amps) 5.4 A
Type of Relay PTC Starter
Capacitor N/A (RSIR Configuration)
Country of Origin Slovakia

Efficiency Metrics (COP) & Performance Data

The efficiency of the ES7FT.4 is measured by its Coefficient of Performance (COP). Below is the performance breakdown at various evaporating temperatures (Condensing Temp at +55°C).

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 71.6 107 0.67
-30 99.5 125 0.80
-23.3 (Standard) 147 148 0.99
-20 176 160 1.10
-15 228 179 1.27
-10 290 200 1.45

Comparison with Alternative Models

When comparing the ES7FT.4 to other popular 1/5 HP units, we see distinct differences in displacement and energy draw. For instance, the ZMC GM70AZ offers similar wattage but often utilizes different winding resistances. The Secop ES series is specifically “Energy Optimized,” meaning it prioritizes a lower amperage draw during the long run cycles typical of LBP freezing.

Professional Recommendations & Field Notice

As an expert in the field, I recommend the following for any technician installing the ES7FT.4:

  1. Vacuum Procedure: Always achieve a vacuum of at least 500 microns. R134a and POE oil are highly hygroscopic; moisture will lead to acid formation and premature motor failure.
  2. Filter Drier: Replace the filter drier (minimum 15g-20g XH-9) every time the system is opened.
  3. Start Components: If the compressor fails to start in high-heat environments, ensure the PTC starter is not cracked. These units rely on a clean electrical signal to engage the start winding.

Compressor Replacements (Cross-Reference)

5 Direct Replacements (R134a)

  • Embraco: EMT6170Z or EMY70HSC
  • Danfoss: TLS7F
  • ZMC: GL70AA
  • Tecumseh: THG1365Y
  • Jiaxipera: ND1111Y

5 Replacements (Alternative Gas – R600a)

Note: Requires complete system flushing and capillary adjustment.

  • Secop: TLES7.5KK.3
  • Embraco: EMX70CLC
  • ACC/Seko: HMK80AA
  • Donper: L76CZ1
  • Huayi: HYE69Y

Focus Keyphrase: Secop ES7FT.4 Compressor 1/5 HP R134a Technical Specifications and Replacements

SEO Title: Secop ES7FT.4 Compressor | 1/5 HP | R134a | Mbsmpro.com Technical Guide

Meta Description: Detailed technical sheet for the Secop ES7FT.4 (102G4707) compressor. Includes 1/5 HP power ratings, R134a gas data, cooling capacity tables, and 10 expert replacement options for refrigeration repair.

Slug: secop-es7ft4-compressor-1-5hp-r134a-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Secop, ES7FT.4, 102G4707, 1/5 HP, R134a, LBP Compressor, Refrigerator Repair, EMT6170Z, TLS7F, GL70AA, THG1365Y, ND1111Y, TLES7.5KK.3

Excerpt: The Secop ES7FT.4 is a high-efficiency 1/5 HP hermetic compressor engineered for R134a LBP applications. With a displacement of 5.70 cm³ and a cooling capacity of 147W at -23.3°C, it is an ideal choice for tropical refrigeration. This guide provides full technical data, COP metrics, and professional replacement cross-references for HVAC technicians.

Secop ES7FT.4 Compressor 1/5 HP R134a Technical Specifications and Replacements mbsmpro
1/5 hp, 102G4707, EMT6170Z, ES7FT.4, GL70AA, LBP compressor, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, ND1111Y, R134a, Refrigerator Repair, Secop, THG1365Y, TLS7F



Secop TLES6FT.3 Compressor Technical Specifications, Cooling Capacity, and R134a Replacement Guide for Refrigeration Professionals

Secop TLES6FT.3 Compressor Technical Specifications, Cooling Capacity, and R134a Replacement Guide for Refrigeration Professionals mbsmpro

Focus Keyphrase

Secop TLES6FT.3 Compressor Technical Specifications, Cooling Capacity, and R134a Replacement Guide for Refrigeration Professionals

SEO Title

Mbsmpro.com, Compressor, Secop, TLES6FT.3, 1/6 hp, R134a, LBP, 220-240V 50Hz, Technical Data and Replacements

Meta Description

Technical deep dive into the Secop TLES6FT.3 compressor. Explore cooling capacity, 1/6 HP performance, R134a specs, and a comprehensive replacement guide for HVAC technicians.

Slug

secop-tles6ft3-compressor-specifications-replacement-guide

Tags

Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Secop, TLES6FT.3, Compressor, R134a, 1/6 HP, LBP, Refrigeration, Embraco EMT55HLP, Danfoss TL5G, ACC GVY57AA, Jiaxipera ND1112Y, Cubigel GL60AA, R600a Conversion, HVAC Technical Data

Excerpt

The Secop TLES6FT.3 is a high-efficiency hermetic reciprocating compressor designed specifically for Low Back Pressure (LBP) applications. Operating on R134a refrigerant, this 1/6 HP powerhouse is a staple in domestic refrigeration. This guide breaks down its technical performance, electrical characteristics, and provides reliable replacement options for field workers and engineers looking for precision.


The Heart of the Cold: A Deep Dive into the Secop TLES6FT.3

In the world of professional refrigeration, the compressor is the undisputed champion of the cooling cycle. Among the reliable workhorses found in modern households, the Secop TLES6FT.3 stands out as a precision-engineered component. Manufactured in Slovakia, this unit is built for longevity and steady performance in Low Back Pressure (LBP) environments, such as household refrigerators and small freezers.

Understanding this compressor isn’t just about reading a label; it’s about knowing how it interacts with the entire thermal system. Whether you are a field technician performing a swap or an engineer designing a cooling solution, the technical nuances of the TLES6FT.3 are vital.

Technical Profile: Secop TLES6FT.3

Feature Specification
Model TLES6FT.3 (102G 4609)
Utilization LBP (Low Back Pressure)
Domaine Freezing / Cooling
Horsepower (HP) 1/6 HP
Refrigerant Type R134a
Displacement 6.00 cm³
Cooling Capacity (-23.3°C ASHRAE) 156 Watts (Approx. 532 BTU/h)
Power Supply 220-240V / 50Hz / 1 Phase
Motor Type RSIR/CSIR (LST/HST compatible)
Oil Type and Quantity POE (Polyolester) / 180 ml
Winding Material Copper
Amperage (Rated) 1.1 A
LRA (Locked Rotor Amperage) 7.5 A
Type of Relay PTC or Current Relay
Capacitor Optional (6 µF or 80 µF for HST)
Country of Origin Slovakia

Efficiency Metrics (COP) and Performance Data

Efficiency in a compressor is defined by the Coefficient of Performance (COP). For the TLES6FT.3, the relationship between evaporating temperature and energy consumption is crucial for maintaining energy ratings.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 82 98 0.84
-30 112 114 0.98
-25 148 131 1.13
-23.3 156 138 1.14
-20 188 150 1.25
-15 240 170 1.41
-10 295 192 1.54

Note: The COP is calculated using the formula: $COP = \frac{Q_c}{P}$, where $Q_c$ is the cooling capacity and $P$ is the power input.


Application and Capability

This compressor is typically found in medium-sized domestic refrigerators.

  • Cooling Capacity in Liters: It can efficiently handle cooling for units between 250 to 350 Liters.
  • Cubic Feet: Approximately 8.8 to 12.3 cubic feet.
  • Capillary Tube Suggestion: For LBP R134a systems, a capillary of 0.031 inches (0.78 mm) with a length adjusted to the specific cabinet load is standard.

Comparison: Secop TLES6FT.3 vs. Competitors

When looking at the market, the TLES6FT.3 competes directly with brands like Embraco and ACC. While it offers a very stable 6.0 cc displacement, some competitors might vary slightly in their start torque performance.

Brand Model HP Displacement Gas
Secop TLES6FT.3 1/6 HP 6.00 cc R134a
Embraco EMT55HLP 1/6 HP 5.19 cc R134a
Jiaxipera ND1112Y 1/6 HP 5.80 cc R134a
ACC/Seko GVY57AA 1/6 HP 5.73 cc R134a

Replacement Guide

If you are in the field and cannot find the exact TLES6FT.3, here are the professional-grade alternatives.

5 Direct Replacements (Same Gas: R134a)

  1. Embraco EMT55HLP: Very common, slightly higher efficiency.
  2. Danfoss TL5G: The classic predecessor, extremely durable.
  3. ACC / Cubigel GVY57AA: A direct fit for many European cabinets.
  4. Jiaxipera ND1112Y: Often used in Bosch and Siemens units.
  5. Tecumseh THG1358YKS: A robust alternative with similar mounting.

5 Indirect Replacements (Alternative Gas: R600a)

Caution: Gas conversion requires a complete system flush, different oil, and a specific R600a charging procedure.

  1. Secop TLES6.5KK.3: The natural R600a evolution of this frame.
  2. Embraco EMX55CLC: High efficiency R600a model.
  3. Jiaxipera NT1113Y: Standard R600a replacement.
  4. ACC HXK95AA: Known for very low noise levels.
  5. Wanbao ATA72XL: Budget-friendly R600a alternative for 1/6 HP range.

Professional Advice & Field Tips

  • Oil Management: The TLES6FT.3 uses POE oil. This oil is highly hygroscopic (absorbs moisture quickly). Never leave the compressor open to the atmosphere for more than 15 minutes.
  • System Cleanliness: When replacing a burnt-out compressor, always replace the filter drier and perform a nitrogen purge to ensure no acid remains in the lines.
  • Starting Device: This model supports both LST (Low Starting Torque) and HST (High Starting Torque). If you are working in an area with unstable voltage, adding a start capacitor (HST kit) can significantly extend the motor’s life.

Troubleshooting the TLES6FT.3

Problem Potential Cause Action
Compressor runs but no cold Gas leak or partial blockage Check high-side pressure and capillary.
Clicking sound (Thermal Protector) Faulty relay or seized piston Check LRA and relay resistance.
High vibration Worn internal springs Ensure the external rubber grommets are intact.
Secop TLES6FT.3 Compressor Technical Specifications, Cooling Capacity, and R134a Replacement Guide for Refrigeration Professionals mbsmpro
1/6 HP, ACC GVY57AA, Compressor, Cubigel GL60AA, Danfoss TL5G, Embraco EMT55HLP, Jiaxipera ND1112Y, LBP, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, R600a Conversion, refrigeration, Secop, TLES6FT.3



Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL

Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL mbsmpro

Mbsmpro.com, Compressor, GQY80AT vs ATA72XL, 1/4 hp – 1/5 hp, ZEL, Huaguang, R134a, Cooling, 220V, LBP, Refrigerator Repair


Technical Analysis of High-Performance Hermetic Compressors: GQY80AT and ATA72XL

In the world of refrigeration maintenance and professional appliance repair, choosing the right compressor is the difference between a long-lasting fix and a premature system failure. Today, we are diving deep into the technical specifications of two widely used units in the industry: the ZEL GQY80AT and the Huaguang ATA72XL. Both are designed for R134a refrigerant but serve slightly different cooling capacities and applications.

The GQY80AT, manufactured by Zanussi Elettromeccanica (ZEL), has long been a staple in European-designed domestic freezers and large refrigerators. It is a robust 1/4 HP unit known for its high starting torque and reliability in fluctuating voltage environments. On the other hand, the Huaguang ATA72XL is a highly efficient 1/5 HP+ (often treated as a strong 1/5 or light 1/4) compressor from the Wanbao Group. It is frequently seen in modern energy-efficient refrigerators where low noise and high Coefficient of Performance (COP) are prioritized.

Technical Specification Table

Model ZEL GQY80AT Huaguang ATA72XL
Utilization LBP (Low Back Pressure) LBP (Low Back Pressure)
Domaine Freezing / Cooling Freezing / Cooling
Cooling Wattage (-23.3°C) 198 W 185 W
Cubic Feet Capacity 12 – 16 cu.ft. 10 – 14 cu.ft.
Liters Capacity 350 – 450 L 280 – 400 L
Kcal/h 170 kcal/h 159 kcal/h
Oil Type & Quantity POE (Ester) / 200ml POE (Ester) / 180ml
Horsepower (HP) 1/4 HP 1/5 HP+
Refrigerant Type R134a R134a
Power Supply 200-220V / 50Hz 220-240V / 50-60Hz
Cooling Capacity (BTU) 676 BTU/h 631 BTU/h
Motor Type RSIR / RSCR RSIR
Displacement 8.1 cm³ 7.2 cm³
Winding Material Copper Copper
Pressure Charge 0.5 – 0.8 Bar (Running) 0.4 – 0.7 Bar (Running)
Capillary Size 0.031″ / 3.0m 0.028″ / 3.0m
Temperature Function -35°C to -10°C -30°C to -10°C
Cooling Method Static (No Fan) Static (No Fan)
Commercial Use Light Commercial/Domestic Domestic
Amperage (FLA) 1.3 A 1.1 A
LRA (Locked Rotor) 12 A 10 A
Relay Type PTC PTC
Capacitor Optional (4-5uF) No
Origin China (Zanussi Tech) China (Wanbao)

Efficiency Metrics (COP) Performance Data

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-30 145 125 1.16
-25 182 148 1.23
-23.3 (Standard) 198 155 1.27
-20 235 170 1.38
-15 305 195 1.56
-10 390 220 1.77

Professional Replacement Guide

When the original unit is no longer available, these replacements offer the same displacement and cooling curve characteristics.

5 Direct Replacements (R134a Gas)

  1. Embraco FFI7.5HAK: A heavy-duty 1/4 HP equivalent with high reliability.
  2. Secop (Danfoss) TLES7F: Excellent efficiency for domestic LBP applications.
  3. LG MA72LAEP: A very quiet alternative with similar mounting footprints.
  4. Tecumseh THG1365YS: Known for high tolerance to high ambient temperatures.
  5. Samsung NC44A94ALH: A compact but powerful alternative.

5 Alternative Replacements (R600a Gas Conversion)

Note: Converting to R600a requires a complete system flush and a dedicated R600a capillary/filter.

  1. Secop TLES7.5KK.4: The industry standard for R600a 1/4 HP swaps.
  2. Embraco EMX70CLC: High COP unit for energy-conscious repairs.
  3. Jiaxipera NT1114Y: Widely used in modern inverter-to-fixed-speed conversions.
  4. Donper LU72CZ1: A budget-friendly R600a unit with stable performance.
  5. Wanbao ATA72XL (R600a Version): The direct isobaric sibling of the R134a model.

Expert Engineering Insights & Tips

When installing these compressors, pay close attention to the displacement differences. The GQY80AT (8.1cc) is slightly more powerful than the ATA72XL (7.2cc). If you are replacing a ZEL with a Huaguang, the cooling might be slightly slower in a large chest freezer. Conversely, using a ZEL to replace a Huaguang may result in shorter cycle times, which can lead to higher wear on the relay if not monitored.

Technician’s Checklist:

  • Triple Vacuum: Always pull down to 500 microns to ensure all moisture is removed from the POE oil.
  • Filter Drier: Never reuse a filter. Always install a new 20g or 30g XH-9 molecular sieve drier.
  • Winding Check: Before brazing, verify the Common, Start, and Main terminals. The GQY80AT has a standard triangular pin configuration.
  • Heat Dissipation: Ensure the condenser coils are cleaned. These static-cooled compressors rely heavily on natural convection or the external cabinet skin for heat exchange.

Focus Keyphrase: ZEL GQY80AT and Huaguang ATA72XL Compressor Specifications and Replacement Guide

SEO Title: Mbsmpro.com, Compressor, GQY80AT, ATA72XL, 1/4 HP, R134a, Technical Data

Meta Description: Detailed technical analysis of ZEL GQY80AT and Huaguang ATA72XL compressors. Includes BTU, wattage, cooling capacity, and 10 professional replacement models for R134a and R600a. Perfect for refrigeration engineers and professional technicians.

Slug: zel-gqy80at-huaguang-ata72xl-compressor-specs-replacement

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, ZEL, GQY80AT, Huaguang, ATA72XL, R134a, 1/4 HP, 1/5 HP, Embraco FFI7.5HAK, Secop TLES7F, LG MA72LAEP, Tecumseh THG1365YS, Refrigeration Repair, Compressor Replacement, LBP Compressor

Excerpt: Choosing between the ZEL GQY80AT and Huaguang ATA72XL requires a deep understanding of displacement and cooling wattage. This professional guide breaks down the 198W capacity of the GQY80AT versus the 185W of the ATA72XL, providing essential data for technicians, including oil types, motor configurations, and a comprehensive list of cross-compatible replacement models.




Donper LG83WZ1 Refrigeration Compressor Technical Specifications and R134a Replacement Guide for Unionaire refrigerator

Donper LG83WZ1 Refrigeration Compressor Technical Specifications and R134a Replacement Guide for Unionaire refrigerator mbsmpro

Focus Keyphrase: Donper LG83WZ1 Refrigeration Compressor Technical Specifications and R134a Replacement Guide

SEO Title: Mbsmpro.com, Compressor, LG83WZ1, 1/4 HP+, Donper, Cooling, R134a, 230 W, 1.4 A, 1Ph 220-240V 50Hz, LBP, Freezing

Meta Description: Explore the comprehensive technical specs for the Donper LG83WZ1 compressor. Includes cooling capacity, replacement cross-references, and performance data for R134a systems.

Slug: donper-lg83wz1-compressor-specifications-r134a-replacement

Tags: Donper, LG83WZ1, R134a, 1/4 HP+, Refrigerator Compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco FFI8.5HAK, Secop NLE8.8MF, LG MA88LAEP, Panasonic QB86C16GAX5, Tecumseh THG1374YS, LBP Compressor

Excerpt: The Donper LG83WZ1 stands as a cornerstone in modern domestic and light commercial refrigeration. Engineered for Low Back Pressure applications, this R134a-driven unit provides reliable cooling capacity for medium to large refrigerators. Its 8.3cc displacement ensures consistent thermal management, making it a preferred choice for technicians seeking a robust, thermally protected motor for demanding climates.


The Engineering Behind Reliability: A Deep Dive into the Donper LG83WZ1 Compressor

In the precision-driven world of refrigeration, the compressor is the heart of the thermal cycle. Among the workhorses found in modern residential and light commercial units, the Donper LG83WZ1 has earned a reputation for resilience and steady performance. As a Low Back Pressure (LBP) specialist, this model is specifically designed to handle the rigorous demands of freezing and deep-cooling applications where maintaining sub-zero temperatures is non-negotiable.

Technical Performance and Infrastructure

The LG83WZ1 utilizes R134a refrigerant, a long-standing industry standard known for its thermodynamic stability. With a displacement of 8.3 cm³, it sits comfortably in the 1/4 HP+ to 1/3 HP class, providing enough “muscle” for large household refrigerators or vertical display freezers. The motor is a single-phase, thermally protected unit operating on a standard 220-240V 50Hz supply, making it a universal fit for many international markets.


Comprehensive Technical Specifications

Feature Specification
Model LG83WZ1
Utilization LBP (Low Back Pressure)
Domaine Freezing / Deep Cooling
Cooling Wattage at -23.3°C 230 W
Cubic Feet Capacity 14 – 18 cu.ft.
Liters Capacity 400 – 500 Liters
Kcal/h 198 Kcal/h
Oil Type and Quantity Ester Oil (POE) / 180ml
Horsepower (HP) 1/4 HP+
Refrigerant Type R134a
Power Supply 220–240V / 50Hz / 1Ph
Cooling Capacity (BTU/h) 785 BTU/h
Motor Type RSIR / RSCR (depending on start kit)
Displacement 8.3 cm³
Winding Material High-Grade Copper
Suction Pressure Charge 0.5 to 1.2 Bar (system dependent)
Capillary Recommendation 0.031″ or 0.036″ ID
Common Application Double-door refrigerators, Chest Freezers
Temperature Function -35°C to -15°C
Cooling Method Static or Fan Assisted
Commercial Status Semi-Commercial / Residential
Amperage (FLA) 1.4 A
LRA (Locked Rotor Amps) 11.5 A
Relay Type PTC or Magnetic
Start Capacitor Optional (usually 60-80 µF if used)
Origin China (Global Export)

Efficiency Metrics (COP)

Understanding the Coefficient of Performance (COP) is vital for energy-conscious engineering. The LG83WZ1 shows its strengths in the mid-range of LBP operations.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-30 165 148 1.11
-25 215 165 1.30
-23.3 (ASHRAE) 230 172 1.34
-20 275 185 1.48
-15 345 205 1.68
-10 430 230 1.87

Direct Replacement Cross-Reference

When a compressor fails in the field, speed and accuracy in replacement are paramount. Below are the most compatible units based on displacement and cooling capacity.

5 Replacements: Same Refrigerant (R134a)

Brand Model HP Equivalent Displacement
Embraco FFI8.5HAK 1/4 HP+ 8.5 cm³
Secop NLE8.8MF 1/3 HP 8.8 cm³
LG MA88LAEP 1/4 HP+ 8.8 cm³
Panasonic QB86C16GAX5 1/4 HP+ 8.6 cm³
Tecumseh THG1374YS 1/4 HP 7.4 cm³

5 Replacements: Alternative Refrigerant (R600a)

Note: Converting from R134a to R600a requires a complete system flush, lubricant change, and capillary adjustment.

| Brand | Model | HP Equivalent | Gas Type |

| :— | :— | :— | :— |

| Embraco | EMX70CLC | 1/4 HP | R600a |

| Secop | TLES7.5KK.3 | 1/4 HP | R600a |

| LG | MK88LAEM | 1/4 HP+ | R600a |

| Donper | B80H | 1/4 HP | R600a |

| Jiaxipera | NT1114Y | 1/4 HP | R600a |


Comparative Analysis: R134a vs. R600a Performance

While the LG83WZ1 uses R134a, the industry is shifting toward R600a (Isobutane). Comparing these two helps technicians understand why the LG83WZ1 remains a staple for repairs:

  • Pressure: R134a operates at higher discharge pressures than R600a, allowing for faster heat transfer in smaller condenser coils.
  • Charge Weight: R134a systems require a higher gram-weight charge than R600a, making the LG83WZ1 less sensitive to minor leaks.
  • Oil Compatibility: The LG83WZ1 uses POE (Polyolester) oil, which is highly hygroscopic. Unlike the mineral oils used in R600a units, the LG83WZ1 requires strict moisture control during service.

Electrical Schematic and Wiring Guide

For field workers, identifying the terminal configuration is the first step to a successful installation. The LG83WZ1 typically follows the standard triangular pin layout.

Engineering Tip: Always verify the resistance between the Start (S), Main (M), and Common (C) terminals. On the LG83WZ1, the Main winding typically shows lower resistance than the Start winding.


Field Advice and Professional Notices

  • Vacuum Integrity: Because this compressor uses Ester oil, you must pull a vacuum to at least 500 microns. Moisture reacting with POE oil creates acid that can etch the motor windings, leading to premature burnout.
  • Filter Drier Replacement: Never install a new LG83WZ1 without replacing the filter drier. A clogged drier is the number one cause of high head pressure and motor failure.
  • Condenser Maintenance: In commercial settings, ensure the condenser fins are cleaned every six months. The LG83WZ1 is robust, but excessive heat from a dirty condenser will trip the thermal protector and reduce the unit’s lifespan.

Benefits for the End User

  1. Low Noise Floor: Designed with internal dampening springs to reduce vibration.
  2. High Torque Start: Capable of starting under moderate pressure fluctuations, making it reliable in regions with unstable power grids.
  3. Longevity: When paired with a clean system, these compressors are known to exceed 10 years of service life.

Donper LG83WZ1 Refrigeration Compressor Technical Specifications and R134a Replacement Guide for Unionaire refrigerator mbsmpro
Unionaire refrigerator



Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide mbsmpro

Mbsmpro.com, Compressor, Secop, TLES6FT.3, 1/5 HP, R134a, Cooling, 149 W, 1.1 A, 1Ph 220-240V 50Hz, LBP, RSIR/CSIR, Slovakian Engineering


When it comes to domestic refrigeration, few names carry as much weight as Secop. Formerly known under the Danfoss brand, these Slovakian-made powerhouses have become the backbone of reliable household cooling. Today, we’re breaking down the TLES6FT.3, a Low Back Pressure (LBP) compressor designed for efficiency and long-term durability in R134a systems.

If you’re a technician in the field, you know that the TLES series is prized for its compact footprint and low noise levels. It’s a “set it and forget it” component that handles the rigorous demands of modern energy standards without breaking a sweat.


Technical Data & Performance Specifications

The following data provides a granular look at the mechanical and electrical heart of this unit.

Feature Specification
Model TLES6FT.3
Utilisation LBP (Low Back Pressure)
Domaine Freezing / Cooling
Cooling Wattage (-23.3°C) 149 Watts (ASHRAE)
Cooling Capacity (BTU/h) 508 BTU/h
Cubic Feet Capacity Approx. 7 to 9.5 cu. ft.
Liters Capacity 200 – 270 Liters
Kcal/h 128 Kcal/h
Oil Type and Quantity POE (Polyolester) / 180 ml
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V / 50Hz / 1 Phase
Motor Type RSIR/CSIR (Depending on Starter)
Displacement 5.70 cm³
Winding Material Copper
Pressure Charge Low Pressure (Suction Side)
Capillary Tube (Suggested) 0.031″ ID x 3 meters (Approx.)
Appliance Type Refrigerators, Deep Freezers
Operating Temp Range -35°C to -10°C
Cooling Method Static (No Fan Required)
Commercial Class Domestic / Light Commercial
Amperage (RLA) 0.95 A – 1.1 A
Locked Rotor Amps (LRA) 7.5 A
Start Relay PTC or Electromagnetic
Run Capacitor Optional (usually not required for RSIR)
Country of Origin Slovakia

Efficiency Metrics (COP) & Performance Curve

Efficiency is where the TLES6FT.3 truly shines. The Coefficient of Performance (COP) varies based on the evaporating temperature. Use this table for precise diagnostics during system charging.

Evaporating Temp (°C) Cooling Capacity (Watts) Power Consumption (Watts) COP (W/W)
-35 82 88 0.93
-30 110 102 1.08
-23.3 (Standard) 149 122 1.22
-20 172 134 1.28
-15 215 150 1.43
-10 268 168 1.60

Wiring & Connection Schematic

For the electrics, the TLES6FT.3 utilizes a standard triangular pin configuration. Proper wiring is essential to prevent winding burnout.

  • Common (C): Top Pin.
  • Run (R): Bottom Right Pin.
  • Start (S): Bottom Left Pin.
  • Logic: The PTC starter bridges the Start and Run windings briefly to initiate rotation. If using a CSIR setup, a start capacitor (usually 60-80 µF) is placed in series with the start winding.

Cross-Reference & Replacement Guide

If the TLES6FT.3 is unavailable, these alternatives offer similar displacement and BTU output.

Direct R134a Replacements (Same Gas)

  1. Embraco: EMS 55 HLC / EMYe 70 CLP
  2. ZMC/Zem: GL60AA
  3. ACC / Cubigel: GVY57AA
  4. Huayi: HYE60MT
  5. Tecumseh: THB1355Y

R600a Conversion Alternatives (Requires System Flush)

Note: Converting from R134a to R600a requires a complete change of the capillary tube and filter drier.

  1. Secop: TLY5.7KK.3
  2. Embraco: EMX55CLC
  3. Jiaxipera: T1114Y
  4. Sikap: HMK95AA
  5. Donper: L72CZ1

Expert Insight: Installation & Maintenance Notice

As a field engineer, I’ve seen these units last 15+ years when installed correctly. The TLES6FT.3 is a “high-tolerance” unit, but it is sensitive to moisture. Because it uses POE oil, which is highly hygroscopic (absorbs water), you must keep the system sealed until the very moment of brazing.

  • Pro-Tip: Always replace the filter drier when swapping this compressor. A 15g or 20g drier is standard for this capacity.
  • Vacuuming: Do not skip the vacuum stage. A minimum of 250 microns is recommended to ensure the POE oil remains stable.
  • Charging: Charge by weight according to the refrigerator manufacturer’s label. Overcharging R134a systems will lead to high head pressure and premature valve failure.

Focus Keyphrase

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide

SEO Title

Mbsmpro.com | Secop TLES6FT.3 Compressor | 1/5 HP | R134a | LBP Guide

Meta Description

Get the technical specs for the Secop TLES6FT.3 compressor. 1/5 HP, R134a, 149W cooling capacity. Includes wiring diagrams, replacement cross-references, and expert COP tables.

Slug

secop-tles6ft-3-compressor-r134a-1-5hp-specs

Tags

Secop, TLES6FT.3, R134a, 1/5 HP, Compressor, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Slovakia, LBP, EMS55HLC, GL60AA, GVY57AA, HYE60MT, THB1355Y, Refrigeration Repair, Danfoss Compressor

Excerpt

The Secop TLES6FT.3 is a cornerstone of modern domestic refrigeration. This 1/5 HP, R134a compressor is engineered in Slovakia for Low Back Pressure applications, offering a cooling capacity of 149W. Known for its quiet operation and energy efficiency, it is the ideal choice for medium-sized refrigerators and deep freezers looking for long-term reliability.

Secop TLES6FT.3 R134a 1/5 HP LBP Compressor Specifications and Replacement Guide mbsmpro
1/5 hp, Compressor, EMS55HLC, GL60AA, GVY57AA, HYE60MT, LBP, mbsm, mbsm.pro, mbsmgroup, mbsmpro.com, R134a, Refrigeration Repair, Secop, Slovakia, THB1355Y, TLES6FT.3



Siberia GFF57AA Compressor

Siberia GFF57AA Compressor mbsmpro

Mbsmpro.com, Compressor, Siberia, GFF57AA, 1/5 hp, Cooling, R134a, 166 W, 220-240V 50Hz, LBP, RSIR, -35°C to -15°C, Freezing

Technical Specifications Table

Feature Specification
Model GFF57AA (Siberia / Bingfeng)
Utilization LBP (Low Back Pressure)
Field of Application Freezing and Deep Cooling
Oil Type and Quantity Ester Oil (POE), 180ml – 200ml
Horsepower (HP) 1/5 HP
Refrigerant Type R134a
Power Supply 220-240V ~ 50Hz
Cooling Capacity 166 W / 566 BTU/h (ASHRAE)
Motor Type RSIR (Resistive Start, Inductive Run)
Displacement 5.70 cm³
Winding Material Copper/Aluminum Alloy (Model specific)
Charge Pressure (Low Side) 0.5 to 1.5 PSI (Running)
Capillary Tube Recommendation 0.031″ ID (approx. 2.5m – 3m based on application)
Compatible Equipment Domestic Refrigerators, Chest Freezers, Water Dispensers
Evaporating Temperature Range -35°C to -15°C (-31°F to 5°F)
Cooling Method Static Cooling (No fan required for compressor body)
Commercial Classification Residential / Light Commercial
Operating Amperage 1.1 A to 1.3 A
LRA (Locked Rotor Amps) 8.5 A
Type of Relay PTC Start Relay
Capacitor Requirement Usually None (RSIR); Optional 4µF-5µF for Efficiency

Compressor Cross-Reference (Direct Replacements)

5 Replacements in the Same Gas (R134a):

  1. Embraco: EMT56CLP
  2. Secop (Danfoss): TLES5.7FT.3
  3. ZMC: GLY60AA
  4. Jiaxipera: ND1112Y
  5. Huayi: HYE55ANL

5 Replacements in Different Gas (R600a Conversion – Requires system flush):

  1. Embraco: EMX55CLC
  2. Secop: TLES5.7KK.3
  3. Donper: S65CY
  4. Siberia: GFT57AA (R600a version)
  5. Jiaxipera: NT1112Y

Mbsmpro.com, Compressor, GFF57AA, 1/5 hp, Siberia, Cooling, R134a, 166 W, 1.2 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -15°C

In the world of domestic refrigeration, reliability is measured by the silence and efficiency of the compressor. The Siberia GFF57AA stands out as a high-performance hermetic reciprocating compressor specifically engineered for Low Back Pressure (LBP) applications. Manufactured by the renowned Zhejiang Bingfeng group, this unit has become a staple for technicians looking for a robust 1/5 HP solution in modern household appliances.

Engineering Mastery: The 5.7cc Displacement

The GFF57AA utilizes a 5.70 cm³ displacement, which is the “sweet spot” for medium-sized household refrigerators and chest freezers. Unlike larger industrial units, this compressor focuses on thermal stability. In LBP environments, where evaporating temperatures drop as low as -35°C, the internal motor must manage significant pressure differentials without overheating. The RSIR motor configuration ensures a simplified electrical setup, reducing the points of failure by eliminating the need for complex run capacitors in standard configurations.

Performance Comparison: R134a vs. R600a Alternatives

While the industry has seen a shift toward R600a (Isobutane), the R134a GFF57AA remains vital for the service and repair of millions of existing units.

  • Volumetric Efficiency: R134a provides a higher cooling capacity per unit of displacement compared to R600a.
  • Operating Pressures: The GFF57AA operates at higher discharge pressures than its R600a counterparts, which allows for smaller condenser footprints in compact refrigerator designs.

Electrical Schema and Terminal Logic

For the field engineer, understanding the terminal layout is essential for troubleshooting. The GFF57AA follows the standard triangular terminal configuration:

  • Common (C): Top pin (standard orientation).
  • Start (S): Typically the right-hand pin.
  • Main (M/Run): Typically the left-hand pin.

Maintenance Wisdom for Technicians

To maximize the lifespan of the Siberia GFF57AA, pay close attention to the Starting Device. The PTC (Positive Temperature Coefficient) relay is the most common failure point. If the compressor hums but fails to start, always check the PTC resistance before condemning the motor windings. Furthermore, since this is a static-cooled compressor, ensuring adequate airflow around the refrigerator’s rear compartment is the single best way to prevent thermal overload and oil breakdown.

Notice: Always ensure the system is vacuumed to at least 500 microns before charging with R134a to prevent moisture-related capillary blockage, a common issue in LBP systems using POE oils.


Focus Keyphrase: Siberia GFF57AA Compressor

SEO Title: Mbsmpro.com | Siberia GFF57AA 1/5 HP R134a Refrigerator Compressor Specs

Meta Description: Detailed technical guide for the Siberia GFF57AA 1/5 HP compressor. Includes cooling capacity (166W), R134a specs, replacement models, and electrical wiring data for technicians.

Slug: siberia-gff57aa-compressor-1-5-hp-r134a-specs

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Siberia GFF57AA, Bingfeng Compressor, 1/5 HP Compressor, R134a LBP, EMT56CLP replacement, GLY60AA replacement, Refrigerator Repair, HVAC Engineering.

Excerpt: The Siberia GFF57AA is a high-performance 1/5 HP hermetic reciprocating compressor designed for Low Back Pressure (LBP) applications. Utilizing R134a refrigerant and a 5.7cc displacement, it provides a reliable cooling capacity of 166W. This unit is widely used in domestic freezers and refrigerators, offering a robust RSIR motor for 220-240V 50Hz electrical systems.

Siberia GFF57AA Compressor mbsmpro