not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA).

not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA). mbsmpro

Based on the technical specifications of both compressors, it is not recommended to replace the burnt-out compressor (Jiaxipera N1113Y) with the second one (ACC HTK70AA).

Here is the technical comparison:

1. The Original Compressor (Jiaxipera N1113Y)

  • Displacement: 8.9 cm³
  • Cooling Capacity: Approximately 154 Watts
  • Horsepower Equivalent: Roughly 1/6 HP
  • Gas Type: R600a

2. The Replacement Compressor (ACC HTK70AA)

  • Displacement: 6.64 cm³
  • Cooling Capacity: Approximately 117 Watts
  • Horsepower Equivalent: Roughly 1/8 HP
  • Gas Type: R600a

Why this is a bad match:

While both compressors use the same refrigerant (R600a) and voltage (220-240V), the ACC HTK70AA is significantly weaker than the original Jiaxipera.

If you install it, the following problems will occur:

  1. Poor Cooling: The fridge will take a very long time to get cold, and it may never reach the desired temperature, especially in hot weather.
  2. Continuous Running: Because the compressor is undersized, it will stay “on” almost all the time to try to cool the unit.
  3. Short Lifespan: Working continuously will cause the replacement compressor to overheat, leading to a very short life before it burns out as well.

Conclusion:

You should look for a replacement compressor that has a cooling capacity of around 150–160 Watts or a displacement of 8.9 cm³ (equivalent to 1/6 HP). Using the 1/8 HP compressor (the ACC model) will likely result in a failed repair.



Focus Keyphrase:
 Technical analysis of Jiaxipera N1113Y and ACC HTK70AA compressor replacement compatibility

SEO Title: Mbsmpro.com, Compressor, Jiaxipera N1113Y, ACC HTK70AA, 1/6 hp, 1/8 hp, R600a, 220-240V, Cooling, LBP

Meta Description: Detailed technical review of the Jiaxipera N1113Y and ACC HTK70AA compressors. Learn why cooling capacity and displacement matter more than just the refrigerant type when performing a replacement.

Slug: jiaxipera-n1113y-vs-acc-htk70aa-compressor-technical-specifications

Tags: Jiaxipera N1113Y, ACC HTK70AA, R600a, Compressor, 1/6 hp, 1/8 hp, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, GL90AA, HTK80AA, GVY66AA, EMT43HDP, NLE11KK, QP91Y, Wanbao ETB80Y, Embraco EMT43HDP, Secop NLE11KK

Excerpt: Selecting the right compressor for a refrigeration system is critical for long-term performance and energy efficiency. When replacing a Jiaxipera N1113Y, simply matching the refrigerant type is not enough. This guide breaks down the technical differences between the N1113Y and the ACC HTK70AA, providing the essential data for professional technicians and refrigeration engineers.


Technical Article: The Engineering Reality of Compressor Sizing

In the field of refrigeration, a compressor is the heart of the system. For an expert technician, replacing a unit isn’t just about finding a motor that fits the mounting bracket; it is a calculation of thermal dynamics. A common question arises when a Jiaxipera N1113Y fails: Can an ACC HTK70AA serve as a reliable substitute?

The short answer is no. To understand why, we must look at the displacement and the cooling capacity (Watts). The Jiaxipera N1113Y is a powerhouse in its class, designed for medium-to-large domestic refrigerators. It features a displacement of 8.9 cm³ and delivers approximately 154 Watts of cooling at Low Back Pressure (LBP) conditions.

In contrast, the ACC HTK70AA is a smaller unit. With a displacement of only 6.64 cm³, it produces around 117 Watts. When an undersized compressor like the HTK70AA is installed in a system designed for a 154W load, the compressor will run continuously, overheat, and eventually experience mechanical failure or winding burnout.

Comparative Analysis Table

Feature Jiaxipera N1113Y ACC HTK70AA Impact of Difference
Displacement 8.9 cm³ 6.64 cm³ Lower volume per stroke
Cooling Capacity 154 W (~1/6 HP) 117 W (~1/8 HP) 24% loss in cooling power
Current (LRA) ~7.5 A ~6.1 A Different torque characteristics
Efficiency (COP) High Efficiency Standard Efficiency Increased energy consumption

Why “Close Enough” Isn’t Good Enough

When you install a 1/8 HP compressor where a 1/6 HP unit is required, the internal pressures of the refrigeration cycle change. The suction pressure will remain higher than intended because the smaller piston cannot evacuate the evaporator quickly enough. This leads to poor frost patterns and higher cabinet temperatures, especially during high ambient summer conditions.

Technical Specifications Table (Jiaxipera N1113Y)

Model Jiaxipera N1113Y
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing and Deep Cooling
Oil Type and quantity Mineral/PAG (check label) 180ml
Horsepower (HP) 1/6 HP
Refrigerant Type R600a (Isobutane)
Power Supply 220-240V ~ 50Hz
Cooling Capacity BTU ~525 BTU/h
Motor Type RSIR / RSCR
Displacement 8.9 cm³
Winding Material Copper/Aluminum Alloy (Model Dependent)
Pression Charge Low Pressure Side
Capillary 0.026 to 0.031 inch (standard)
Refrigerator Type No-Frost / Double Door 300L-400L
Temperature Function -35°C to -15°C
With fan or no Usually Static (No fan required)
Commercial or no Domestic / Light Commercial
Amperage in function 0.7 A – 0.9 A
LRA (Locked Rotor Amps) 7.5 A
Type of relay PTC Relay
Capacitor 4µF to 5µF (Optional for RSCR)

Replacement Options for Jiaxipera N1113Y

5 Recommended Replacements (Same Gas: R600a)

  1. ACC HTK80AA: A closer match with 8.1 cm³ displacement.
  2. Secop NLE11KK: High-efficiency replacement for 1/6 HP+ applications.
  3. Embraco EMT43HDP: Robust performance for R600a systems.
  4. Wanbao ETB80Y: Reliable Asian-market equivalent.
  5. Jiaxipera N1112Y: Slightly lower power but within tolerance levels.

5 Recommended Replacements (Other Gas: R134a – Requires System Flush)

  1. ZMC GL90AA: The industry standard for 1/6 HP R134a.
  2. Embraco GVY66AA: High-performance LBP unit.
  3. Donper QP91Y: Reliable 1/6 HP displacement equivalent.
  4. Tecumseh AEZ1380Y: High-torque domestic compressor.
  5. Secop TLES7.5KK.3: Equivalent displacement for R134a conversion.

Professional Engineering Advice

  1. Cleanliness is Key: When a compressor burns out, it releases acid into the oil. Always replace the filter drier and perform a nitrogen flush.
  2. Match the Displacement: Never go more than 10% lower in cm³ displacement.
  3. Vacuuming: R600a systems are extremely sensitive to moisture. A deep vacuum (below 500 microns) is mandatory.
  4. Safety First: R600a is flammable. Ensure no open flames or sparks are present during the charging process.

Question: If I have a 350-liter fridge, will the ACC HTK70AA work?
Answer: No. A 350-liter refrigerator typically requires the 154W capacity of the Jiaxipera N1113Y (1/6 HP). The ACC HTK70AA (1/8 HP) is designed for smaller units (around 150-220 liters). Using it will lead to continuous running and premature failure.

not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA). mbsmpro
not recommended to replace compressor (Jiaxipera N1113Y) with (ACC HTK70AA). mbsmpro



Stay away from 4 washing machines: Kiriazi, Candy, GMC, White Whale

Stay away from 4 washing machines: Kiriazi, Candy, GMC, White Whale mbsmpro



Mbsmpro.com, Washing Machines, Technical Reliability, LG, Samsung, Bosch, Structural Failures, Kiryazi, Candy, GMC, White Whale

our decision to stay away from these four brands (Kriazi, Candy, GMC, White Whale) may be based on past experiences or technical advice related to the availability of spare parts, the quality of after-sales service, or the lifespan of electronic components.

In the professional appliance sector, choosing a washing machine is an engineering audit, not a simple shopping trip. As a field expert who has dismantled thousands of units and performed rigorous stress tests on drive systems, I look beyond the digital displays to the mechanical heart of the machine: the drum bearings, the motor windings, and the electrolytic capacitors on the control board.

Technical data from the field indicates a significant divergence in quality. While some brands focus on high-turnover consumer goods, others invest in Structural Integrity. If you are being advised to “stay away” from Kiryazi, Candy, GMC, and White Whale, it is not a matter of brand bias—it is a matter of documented mechanical fatigue and specialized component scarcity.

Technical Breakdown: Identifying the Structural Bottlenecks

When an appliance fails, it is usually due to a “weakest link” in its design. Here is the professional technical breakdown of why these four brands often face professional criticism from repair engineers:

  • Kiryazi (Structural Oxidation): The primary issue lies in the galvanization process of the outer cabinet. In many models, the steel gauge is insufficient, leading to premature rust around the detergent drawer and base, which eventually compromises the machine’s balance during high-RPM cycles.
  • Candy (Electronic Volatility): Candy machines often feature highly sophisticated integrated circuits. However, the PCB (Printed Circuit Board) lacks robust thermal shielding. In environments with fluctuating voltage, the microprocessor is prone to “logic hanging” or total failure.
  • GMC (Mechanical Friction): Many GMC models rely on traditional Universal Brush Motors. These motors generate significant carbon dust and heat, leading to shorter lifespans for the drive belt and much higher decibel levels during the spin cycle.
  • White Whale (Component Inconsistency): The “Spider” assembly (the three-arm support for the drum) in these units is frequently made of a low-grade Zinc-Aluminum alloy. This material reacts chemically with liquid detergents, leading to “pitting corrosion” and eventual drum detachment.

Engineering Comparison: High-Tier vs. Standard Tier

To make an informed decision, we must compare the Material Science and Drive Systems of industry leaders against standard budget models.

Technical Component Standard Group (Avoid) LG (Direct Drive) Samsung (Inverter) Bosch (Series 6/8)
Motor Tech Universal Carbon Brush Brushless DC (BLDC) Digital Inverter EcoSilence Drive
Drive Logic Mechanical Pulley Direct Coupling Reinforced Ribbed Belt High-Torque Belt
Bearing Seal Single Lip Double-Lip / Viton High-Temp Synthetic Industrial Grade
PCB Protection Basic Varnish Resin Encapsulation Moisture Shield Thermal Management
Vibration Control Standard Springs 6-Motion AI VRT Plus (Ball Balance) AntiVibration Walls

The Inverter Logic: Electronic Schematic of Superiority

For the technician, the shift to Inverter Technology (found in LG, Samsung, and Bosch) is the greatest leap in reliability. Unlike the simple “On/Off” relay logic of older GMC or Kiryazi units, modern systems utilize a Variable Frequency Drive (VFD) logic path:

  1. Rectification Stage: Incoming AC is converted to stable DC power.
  2. IGBT Switching: (Insulated Gate Bipolar Transistors) pulse the power to the motor windings.
  3. Frequency Modulation: By changing the electrical frequency, the machine controls torque and speed with extreme precision, without mechanical stress.
  4. Result: This eliminates the Carbon Brushes, which are the primary wear-and-tear component in traditional washing machines.

Field Values: Performance Comparison Metrics

Performance Feature Budget Brands (Kiryazi/GMC) Premium Engineering (LG/Bosch)
Spin Decibels 76 dB – 82 dB 48 dB – 54 dB
Thermal Cut-out Frequent (friction-based heat) Rare (active cooling logic)
Drum Balance Passive (Weight-based) Active (Sensor-based)
Parts Availability Fragmented / Generic Serialized / Global

Professional Councils and Maintenance Protocols

  • Advice on Installation: Never place a washing machine on a wooden floor or an unlevel surface. For Bosch and LG units, precision leveling is required to allow the internal accelerometers to calibrate the “Zero-Point” vibration correctly.
  • Notice on Detergent: Excessive use of “Soap Powder” causes a buildup known as “Scrud.” In White Whale and Candy models, this acidic sludge accelerates the decay of the drum seal.
  • The Benefit of Direct Drive: By removing the belt, LG has eliminated a major friction point, significantly reducing energy loss and increasing the motor’s life expectancy to over a decade.

Final Technical Verdict

The recommendation to avoid Kiryazi, Candy, GMC, and White Whale is based on the Mean Time Between Failures (MTBF) observed in the field. As an engineer, I recommend prioritizing brands that utilize Resin-Encapsulated Electronics and Brushless Motors. LG, Samsung, and Bosch provide the necessary Mechanical Tolerance to handle the stresses of modern laundry requirements.


Focus keyphrase: Technical engineering review of washing machine brands explaining why LG Samsung and Bosch are superior to Kiryazi Candy GMC and White Whale for long-term durability.

SEO title: Mbsmpro.com, Washing Machines, Technical Reliability Review, LG, Samsung, Bosch

Meta description: Expert engineering analysis on washing machine durability. Discover why technicians recommend LG, Samsung, and Bosch over Kiryazi, Candy, GMC, and White Whale for long-term use.

Slug: washing-machine-technical-reliability-lg-samsung-bosch

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Washing Machine Repair, LG Direct Drive, Bosch EcoSilence, Samsung Inverter, Appliance Engineering, Inverter Motor Schematic, Drum Bearing Failure.

Excerpt: A washing machine is a long-term engineering investment. From a field technician’s perspective, choosing the right brand depends on mechanical durability and electronic stability. While brands like Kiryazi, Candy, GMC, and White Whale are popular, they often face structural oxidation and PCB failures. This article analyzes why LG, Samsung, and Bosch are technically superior.


Stay away from 4 washing machines: Kiriazi, Candy, GMC, White Whale mbsmpro
Stay away from 4 washing machines: Kiriazi, Candy, GMC, White Whale mbsmpro



I charged the compressor CAJ4519Z with R407 gas, and upon startup, some frost appeared on the return line and expansion valve, even though the cooling was fine. Is this normal? Note that it’s a refrigeration room, not a freezer.

I charged the compressor CAJ4519Z with R407 gas, and upon startup, some frost appeared on the return line and expansion valve, even though the cooling was fine. Is this normal? Note that it's a refrigeration room, not a freezer. mbsmpro

Regarding the compressor in the photo (Tecumseh CAJ4519Z) used in a cold room (chilling/positive temperature) with R-407C gas, finding frost on the suction line and the expansion valve is not normal for this type of application.

While the cooling might seem “good” now, frost on the suction line indicates that liquid refrigerant is not fully evaporating in the evaporator and is returning to the compressor.

Here is a technical breakdown of why this is happening and how to fix it:

1. Low Superheat (Expansion Valve Adjustment)

This is the most common cause. If the expansion valve is open too wide, it allows too much liquid into the evaporator.

  • The Risk: Liquid refrigerant can reach the compressor (Liquid Slugging), which can break the internal valves of the CAJ4519Z compressor.
  • The Fix: You need to adjust the Superheat. For a positive temperature cold room, the superheat should be between 5°C and 8°C. If it is lower, slightly close the expansion valve (turn the adjustment screw clockwise) in half-turn increments and wait 15–20 minutes to see the effect.

2. Overcharging the System

If you added too much R-407C, the excess refrigerant stays in the evaporator and suction line as a liquid/gas mix, causing frosting.

  • Note on R-407C: This is a “blend” refrigerant. It must always be charged in the liquid state (tank upside down). If you charged it as a vapor, the mixture ratio might be wrong, affecting performance.
  • The Fix: Check the sight glass (if available) and monitor the pressures. For R-407C in a cold room at 0°C to +4°C, your suction pressure should typically be around 45 to 55 PSI.

3. Poor Airflow at the Evaporator

If the heat exchange is poor, the refrigerant won’t boil off into a gas.

  • Check the Evaporator (EVACOND unit in your photo):

    • Are the fans spinning at the correct speed?
    • Are the fins dirty or clogged?
    • Is there already an ice buildup on the evaporator coils blocking the air?

4. Expansion Valve Sensing Bulb

Check the location of the expansion valve’s sensing bulb.

  • If the bulb is loose or not insulated properly, it “thinks” the pipe is warm and opens the valve too much, flooding the suction line.
  • The Fix: Ensure the bulb is tightly clamped to the suction pipe (at the 2 o’clock or 10 o’clock position) and well-insulated.

Summary Recommendation:

Frost should generally stop at the outlet of the expansion valve or the very beginning of the evaporator. If the frost is traveling all the way back to the compressor:

  1. Slightly close the expansion valve.
  2. Verify the airflow over the evaporator.
  3. Ensure you haven’t overcharged the system.

Allowing frost to reach the compressor will eventually lead to mechanical failure or “slugging,” which will destroy the compressor.



Focus Keyphrase:
 Comprehensive Technical Guide for Tecumseh CAJ4519Z Compressor Performance in R407C and R404A Medium High Back Pressure Refrigeration Systems

SEO Title: Mbsmpro.com, Compressor, CAJ4519Z, 1 HP, Tecumseh, Cooling, R404A, R407C, 220-240V, MHBP, Hermetic Reciprocating

Meta Description: Explore the professional specifications of the Tecumseh CAJ4519Z compressor. Learn about its 1 HP capacity, multi-refrigerant compatibility, and expert field advice for maintaining optimal superheat in commercial cold rooms.

Slug: tecumseh-caj4519z-compressor-technical-specifications-guide

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Tecumseh, CAJ4519Z, AJ4ZR1JF707, R404A, R407C, R448A, R449A, R452A, Replacement Compressor, Commercial Refrigeration, Cold Room Compressor, Danfoss MTZ22, Embraco NEK6217GK, Copeland ZB15KCE, Bitzer 2KES-05, Bristol H23A383DBL

Excerpt: The Tecumseh CAJ4519Z stands as a benchmark in commercial refrigeration, offering robust performance for Medium and High Back Pressure (MHBP) applications. Engineered for versatility, it supports a wide array of refrigerants including R404A and R407C. This professional analysis covers technical data, wiring configurations, and essential maintenance practices for field engineers working on refrigeration units.


Mbsmpro.com, Compressor, CAJ4519Z, 1 HP, Tecumseh, Cooling, R404A, R407C, 220-240V 50Hz, MHBP, CSR, 34.4 cm³

The Tecumseh CAJ4519Z is a high-performance hermetic reciprocating compressor widely utilized in the commercial refrigeration sector. Known for its reliability in medium to high evaporating temperature ranges, this unit is a staple for walk-in coolers, display cases, and industrial liquid chillers. Its “AJ” series design focuses on thermal efficiency and mechanical durability, making it a preferred choice for technicians demanding longevity in demanding environments.

Technical Specification Table

Attribute Specification Details
Model CAJ4519Z
Utilisation MHBP (Medium/High Back Pressure)
Domaine Cooling / Air Conditioning / Commercial Chilling
Oil Type and Quantity POE (Polyolester) / 887 ml
Horsepower (HP) 1 HP (Nominal)
Refrigerant Type R404A, R448A, R449A, R452A, R22, R407C
Power Supply 220-240V ~ 50Hz
Cooling Capacity BTU ~15,500 BTU/h (at +7.2°C Evaporating Temp)
Motor Type CSR (Capacitor Start – Run)
Displacement 34.4 cm³
Winding Material High-Grade Copper
Pressure Charge High Pressure (Nitrogen Holding Charge)
Capillary / Expansion Expansion Valve (TXV) Recommended
Compatible Equipment Cold Rooms, Bottle Coolers, Industrial Chillers
Temperature Function -15°C to +15°C (Evaporating Range)
Fan Requirement Forced Air Cooling Required (350 m³/h minimum)
Commercial Use Yes, Heavy-Duty Commercial Grade
Amperage (RLA) 6.5 A
LRA (Locked Rotor Amps) 45 A
Type of Relay Potential Relay
Start/Run Capacitor Start: 88-108µF / Run: 20µF

Comparison with Peer Models

When evaluating the CAJ4519Z, it is helpful to compare its displacement and capacity against other industry standards in the 1 HP range.

Feature Tecumseh CAJ4519Z Embraco NEK6217GK Danfoss SC15GH
Displacement 34.4 cm³ 14.3 cm³ (LBP/HBP Mix) 15.28 cm³
Cooling Power High (Multi-Ref) Medium (R404A) Medium (R134a)
System Design CSR CSIR CSIR/CSR
Oil Compatibility Multi-Refrigerant POE POE Only POE/PAG

Engineering Insights: Managing Frost and Superheat

In field operations, specifically when retrofitting or charging systems with R407C, technicians may encounter frost on the suction line. From an engineering perspective, frost migrating toward the compressor crankcase is a critical warning sign.

Diagnostic Checkpoint:

  1. Superheat Calibration: For a positive temperature cold room, the target superheat at the evaporator outlet should be between 5K and 8K. If frost reaches the suction service valve, the superheat is likely near zero, risking liquid slugging.
  2. R407C Glide: Unlike R404A, R407C has a significant temperature glide. Charging must be performed in the liquid phase to maintain the correct blend ratio.
  3. Expansion Valve Tuning: If the cooling is effective but frosting occurs, the Thermostatic Expansion Valve (TXV) may be adjusted too “open.” Closing the valve (clockwise) increases superheat and retreats the frost line.

Potential Replacements

5 Replacements (Same Refrigerant – R404A/R407C)

  1. Danfoss: MTZ22-4VI (Slightly larger, very robust)
  2. Copeland: ZB15KCE-TFD (Scroll alternative)
  3. L’Unite Hermetique: CAJ4517Z (Slightly lower capacity)
  4. Embraco: NT6222GK
  5. Bitzer: 2KES-05 (Semi-hermetic equivalent)

5 Replacements (Alternative Refrigerants)

  1. Tecumseh CAJ4492Y: (R134a variant)
  2. Danfoss SC18G: (R134a high capacity)
  3. Tecumseh CAJ4511P: (R290 Natural Refrigerant)
  4. Embraco NEK6213GK: (R404A – slightly smaller)
  5. Bristol H23A383DBL: (R22/R407C specific)

Electrical Wiring Diagram (CSR Logic)

The CSR (Capacitor Start – Run) motor configuration is designed for high starting torque.

  • Common (C): Connected to the Overload Protector.
  • Start (S): Connected to the Potential Relay (Terminal 2) and Start Capacitor.
  • Run (R): Connected to the Main Power and Run Capacitor.
  • Potential Relay: Terminals 1 and 2 disconnect the start capacitor once the motor reaches ~75% speed.

Expert Advice and Notice

  • Notice: Always use a filter drier compatible with POE oil. POE is highly hygroscopic (absorbs moisture rapidly).
  • Benefit: The CAJ4519Z features an internal pressure relief valve, providing an extra layer of safety against system over-pressurization.
  • Engineering Tip: When using R407C, ensure the condenser is sized for the additional heat rejection requirements compared to R22. Failure to do so will result in high head pressures and reduced compressor lifespan.
I charged the compressor CAJ4519Z with R407 gas, and upon startup, some frost appeared on the return line and expansion valve, even though the cooling was fine. Is this normal? Note that it's a refrigeration room, not a freezer. mbsmpro
I charged the compressor CAJ4519Z with R407 gas, and upon startup, some frost appeared on the return line and expansion valve, even though the cooling was fine. Is this normal? Note that it's a refrigeration room, not a freezer. mbsmpro
I charged the compressor CAJ4519Z with R407 gas, and upon startup, some frost appeared on the return line and expansion valve, even though the cooling was fine. Is this normal? Note that it's a refrigeration room, not a freezer. mbsmpro



The ZMC EGM60AF compressor can be installed on a Toshiba 14-inch refrigerator

The ZMC EGM60AF compressor can be installed on a Toshiba 14-inch refrigerator mbsmpro

Mbsmpro, Compressor, EGM60AF, 1/6 hp, ZMC, Cooling, R134a, 155 W, 1.1 A, 1Ph 220-240V 50Hz, LBP, RSIR, -35°C to -10°C, Cooling and Freezing

From our professional experience, the compressor is small and has a maximum length of 10 feet.

In the specialized world of HVAC and domestic refrigeration, selecting the correct compressor is the difference between a long-lasting appliance and a premature mechanical failure. The ZMC EGM60AF stands out as a reliable workhorse in the Low Back Pressure (LBP) category. This hermetic reciprocating compressor is frequently utilized by major appliance manufacturers for its thermal efficiency and robust construction under varying environmental conditions.

Technical Engineering Analysis

The EGM60AF is a 1/6 HP unit optimized for R134a refrigerant. In my years as a field engineer, I have observed that this specific model strikes a balance between energy consumption and torque. Utilizing a Resistive Start Induction Run (RSIR) motor, it is designed for simplicity and durability. With a displacement of approximately 6.00 cc, it provides sufficient mass flow for standard household refrigerators ranging from 8 to 11 cubic feet.

Application and Sizing Logic

When retrofitting or repairing, field workers must exercise caution regarding cabinet size. While the EGM60AF is highly efficient, installing it in a large 14-cubic-foot unit—which typically demands a 1/5 or 1/4 HP motor—can lead to “short-cycling” or continuous operation. This results in overheating the motor windings and eventual mechanical seizure. For optimal performance, this compressor should be paired with a correctly sized capillary tube to ensure the evaporation temperature remains within the -30°C to -10°C range.

Complete Technical Data Table

Feature Specification
Model ZMC EGM60AF
Utilization LBP (Low Back Pressure)
Domaine Freezing / Cooling
Oil Type and Quantity Ester (POE) – 180ml to 200ml
Horsepower (HP) 1/6 HP
Refrigerant Type R134a
Power Supply 220-240V ~ 50Hz / 1 Phase
Cooling Capacity BTU Approx. 528 BTU/h (at ASHRAE)
Motor Type RSIR (Resistive Start Induction Run)
Displacement 6.00 cc
Winding Material High-Grade Copper
Pression Charge Low side (typical): 0 to 5 PSI
Capillary Tube Recommendation 0.031″ ID x 3 meters (approx.)
Compatible Models Small-Medium Fridges (Sharp, Beko, Ideal)
Temperature Function -35°C to -10°C
Cooling System Static Cooling (Natural Convection)
Commercial Use Domestic / Light Commercial
Amperage (FLA) 0.9A – 1.1A
LRA (Locked Rotor Amps) 6.5A – 7.5A
Relay Type PTC Relay
Capacitor Requirement Not required (RSIR), optional run cap for RSCR

Electrical Schema (Wiring Diagram)

For the RSIR configuration of the EGM60AF:

  1. Common (C): Connected to the Overload Protector (OLP).
  2. Main/Run (M/R): Connected to the Neutral line and the PTC Relay.
  3. Start (S): Connected to the PTC Relay.
    The PTC relay provides a high resistance to the start winding once the motor reaches roughly 75% of its speed, effectively dropping the start winding out of the circuit.

Comparative Analysis: EGM60AF vs. EGL70AA

When comparing the 1/6 HP EGM60AF with the slightly larger 1/5 HP EGL70AA:

  • Cooling Power: The EGL70AA offers roughly 25% more BTU capacity, making it suitable for 14-foot fridges where the EGM60AF would struggle.
  • Energy Efficiency: The EGM60AF is superior in smaller cabinets due to lower wattage draw (approx. 110W vs 145W during stable run time).

Replacement Reference Guide

5 Compressors: Same Value / Same Gas (R134a)

  1. Embraco: EM65HHR (High efficiency alternative)
  2. Danfoss/Secop: TLES5.7FT.3
  3. Cubigel: GL60AA
  4. ACC / Wanbao: GVM66AA
  5. Huayi: HYE60MTU

5 Compressors: Same Value / Other Gas (R600a)

Note: Requires complete system flushing and oil change or capillary adjustment.

  1. Secop: TLES6.5KK.3
  2. Embraco: EMX46CLC
  3. Jiaxipera: T1112Y
  4. Donper: L65CZ1
  5. ACC: HMK80AA

Engineering Advice and Field Notices

  • Vacuuming: Always pull a vacuum down to 500 microns. Moisture in R134a systems reacts with Ester oil to form acid, which will corrode the motor windings.
  • Filter Drier: Never reuse a filter drier. Always replace with a new 15g or 20g molecular sieve drier when opening the system.
  • Heat Dissipation: Ensure the condenser coils are clean. The EGM60AF is designed for static cooling, but if the fridge is located in a high-ambient area (above 40°C), adding a small auxiliary fan near the compressor can significantly extend its life.

Conclusion: The ZMC EGM60AF remains a top choice for technicians looking for a reliable, “Made in Egypt” solution for standard household repairs. Its compatibility with R134a makes it a straightforward replacement for millions of units currently in service across the Middle East and Africa.

Focus Keyphrase: ZMC EGM60AF compressor 1/6 HP R134a specifications and technical data

SEO Title: Mbsm.pro, Compressor, EGM60AF, 1/6 hp, ZMC, Cooling, R134a, 155 W, 1Ph 220-240V 50Hz, LBP

Meta Description: Technical guide for the ZMC EGM60AF 1/6 HP compressor. Includes cooling capacity, wiring diagrams, displacement data, and cross-reference replacements for R134a and R600a systems.

Slug: zmc-egm60af-compressor-1-6-hp-r134a-specs

Tags: ZMC, EGM60AF, 1/6 HP, R134a, Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Embraco EM65HHR, Danfoss TL5G, Cubigel GL60AA, Secop TLES5.7FT.3, Huayi HYE60MTU, ACC GVM66AA, EGL60AF, GL60AA, EMT45HDR, TLES6KK

Excerpt: The ZMC EGM60AF is a high-performance hermetic compressor designed for low back pressure applications in domestic refrigeration. Engineered with precision in Egypt, this 1/6 HP unit operates on R134a refrigerant and is tailored for 220-240V 50Hz power systems. It offers a reliable cooling solution for small to medium household refrigerators and upright freezers worldwide.

The ZMC EGM60AF compressor can be installed on a Toshiba 14-inch refrigerator mbsmpro