compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP

donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Compresseur Réfrigérateur DONPER

Référence: K270CZ1R134A 1/3HP

DONPER Refrigerator Compressor

Référence: L58CZ1R134A 1/6HP

DONPERCompresseur Réfrigérateur

Référence: L65CZ1R134A 1/5HP

DONPER Refrigerator Compressor

Référence: L72CZ1R134A 1/4HP

DONPER Refrigerator Compressor

K270CZ1 R134A 1/3HP

DONPER Refrigerator Compressor

K375CZ1R134A 1/2HP

Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

In the HVAC and refrigeration industry, the Donper brand has become a synonymous name for reliability and cost-effective performance. Specializing in hermetic reciprocating technology, Donper’s R134a lineup—specifically the L-series and K-series—covers the vast majority of domestic and light commercial needs. From a small 1/6 HP refrigerator to a robust 1/2 HP commercial chest freezer, these compressors are engineered to handle varying thermal loads with consistent efficiency.

As a field technician or engineer, selecting the correct replacement or designing a system requires more than just knowing the horsepower. It requires a deep dive into displacement, motor torque, and winding characteristics. Below, we provide the definitive technical breakdown of the most common Donper R134a models.


Comparative Analysis: The Donper R134a Series

The transition from the L-series to the K-series marks a shift from residential “static” cooling to more demanding commercial “forced-air” or high-capacity “static” cooling. While the L58CZ1 is the quiet heart of a kitchen fridge, the K375CZ1 is the workhorse of the supermarket display.

Model HP Displacement (cc) Cooling Cap (W) Efficiency (W/W) Motor Type
L58CZ1 1/6 5.8 140 1.15 RSIR
L65CZ1 1/5 6.5 165 1.20 RSIR
L72CZ1 1/4 7.2 195 1.25 RSIR/RSCR
K270CZ1 1/3 9.5 270 1.30 RSCR
K375CZ1 1/2 12.5 375 1.35 CSIR

Detailed Technical Data Sheets

Below are the exhaustive specifications for each model mentioned. This data is critical for calculating capillary tube lengths and ensuring electrical compatibility.

1. Donper L-Series (Domestic Focus)

Feature L58CZ1 (1/6 HP) L65CZ1 (1/5 HP) L72CZ1 (1/4 HP)
Utilisation LBP LBP LBP
Domaine Cooling / Freezing Cooling / Freezing Cooling / Freezing
Oil Type / Qty POE – 180ml POE – 200ml POE – 210ml
Power Supply 220-240V 50Hz 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 478 BTU/h 563 BTU/h 665 BTU/h
Motor Type RSIR RSIR RSIR/RSCR
Winding Material Copper Copper Copper
Pressure Charge 100-120 PSI (Static) 100-120 PSI (Static) 110-130 PSI (Static)
Capillary (Typical) 0.028″ x 3m 0.031″ x 3m 0.036″ x 3m
Fan Required No (Static) No (Static) Optional
LRA (Amps) 6.5 A 8.0 A 9.5 A
Capacitor N/A N/A 4-5 µF (if RSCR)

2. Donper K-Series (Commercial Focus)

Feature K270CZ1 (1/3 HP) K375CZ1 (1/2 HP)
Utilisation LBP / MBP LBP / MBP
Domaine Large Freezing Commercial Freezing
Oil Type / Qty POE – 250ml POE – 300ml
Power Supply 220-240V 50Hz 220-240V 50Hz
Cooling Capacity 921 BTU/h 1280 BTU/h
Motor Type RSCR CSIR (Start Cap)
Winding Material Copper High-Temp Copper
Pressure Charge 120-140 PSI (Static) 140-160 PSI (Static)
Capillary (Typical) 0.042″ x 2.5m 0.050″ x 2.5m
Fan Required Recommended Yes (Forced Air)
LRA (Amps) 12.0 A 18.0 A
Capacitor 6 µF (Run) 60-80 µF (Start)

Cross-Reference & Replacement Guide

When the exact Donper model is unavailable, the following industry-standard alternatives can be utilized. Ensure you verify the mounting foot dimensions as they may vary slightly between brands.

5 Standard Replacements (R134a)

  1. Embraco: FFI10HAK (for 1/3 HP) / FFI12HBX (for 1/2 HP)
  2. Secop/Danfoss: TLES8.7KK.3 / NL11F
  3. Tecumseh: THB1390Y / AEA3440Y
  4. Huayi: HYE90MT / HYE121MT
  5. Jiaxipera: ND1114Y / NT1116Y

5 Alternative Gas Replacements (System Flush Required)

  1. Donper (R600a): D65CY1 (for 1/5 HP applications)
  2. Secop (R290): NLE11KK (High Efficiency)
  3. Embraco (R600a): EMX3115Y
  4. Cubigel (R290): GLY12RA
  5. LG (R600a): BSA075LHE

Engineering Best Practices & Maintenance

Expert Advice: The K375CZ1 (1/2 HP) generates significant heat during the compression cycle. If installing this in a confined space, a condenser fan is non-negotiable. Lack of airflow will lead to oil carbonization and premature valve failure.

  • Vacuuming: Always pull a vacuum down to 500 microns. R134a uses POE oil, which is highly hygroscopic (absorbs moisture). Moisture in the system leads to acid formation that eats through copper windings.
  • Capillary Match: When moving from a 1/6 HP to a 1/4 HP compressor, you must resize the capillary tube. Using an undersized capillary will cause high head pressure and trip the thermal overload protector.
  • Relay Testing: If the compressor fails to start but hums, check the PTC relay or the Start Capacitor (on 1/2 HP models). Donper relays are standardized, but always match the Ohm resistance of the original part.

Focus Keyphrase: Donper R134a Refrigerator Compressor Technical Specs L58CZ1 L65CZ1 L72CZ1 K270CZ1 K375CZ1

SEO Title: Mbsmpro.com, Compressor, Donper, R134a, 1/6 hp to 1/2 hp, K and L Series, Cooling, Technical Data

Meta Description: Full technical data sheets for Donper R134a compressors: L58CZ1 (1/6HP), L65CZ1 (1/5HP), L72CZ1 (1/4HP), K270CZ1 (1/3HP), and K375CZ1 (1/2HP). Includes cross-reference and wiring tips.

Slug: donper-r134a-compressor-specs-l58-l65-l72-k270-k375

Tags: Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, Donper, K270CZ1, L58CZ1, L65CZ1, L72CZ1, K375CZ1, R134a, Refrigerator Compressor, Replacement, LBP, RSIR, CSIR, Embraco Replacement, HVAC, Technical Guide.

Excerpt: Donper has established itself as a powerhouse in the hermetic compressor industry, providing reliable cooling solutions for domestic and light commercial applications. This technical analysis explores the R134a L and K series, ranging from 1/6 HP to 1/2 HP, offering engineers and technicians the critical data needed for successful repairs and system optimizations.


Donper Series – R134a Refrigerant (LBP, 220V/50Hz)

These models feature aluminum windings (Al-wire) and are designed for Low Back Pressure (LBP) applications.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
S53CW1 1/8 HP 135W 220V/50Hz Aluminum
L58CZ1 1/6 HP 145W 220V/50Hz Aluminum
L65CZ1 1/5 HP 170W 220V/50Hz Aluminum
L72CZ1 1/4 HP 195W 220V/50Hz Aluminum
L76CZ1 1/4 HP+ 215W 220V/50Hz Aluminum
K230CZ1 1/4 HP+ 230W 220V/50Hz Aluminum
K270CZ1 1/3 HP 270W 220V/50Hz Aluminum
K325CZ1 1/3 HP 325W 220V/50Hz Aluminum

Donper Series – R600a Refrigerant (LBP, 220V/50Hz)

Models optimized for Isobutane (R600a), also using aluminum motor windings.

Model Power (HP) Cooling Capacity (W) Power Supply Wire Type
A120CY1T 1/8 HP 118W 220V/50Hz Aluminum
A145CY1A 1/6 HP 138W 220V/50Hz Aluminum
S100CY1 1/5 HP 168W 220V/50Hz Aluminum
S118CY1 1/4 HP 200W 220V/50Hz Aluminum
L140CY1 1/4 HP+ 235W 220V/50Hz Aluminum

Technical Definitions

  • LBP (Low Back Pressure): Optimized for low evaporating temperatures (typically -35°C to -10°C), making them ideal for household freezers and refrigerators.
  • Cooling Capacity (W): Measured in Watts, representing the amount of heat the compressor can remove per hour under standard test conditions (ASHRAE).
  • Al-wire (Aluminum Wire): A cost-effective alternative to copper. While lighter, it requires specific handling during repair and is generally found in “entry-level” or standard domestic units.



Compressor, HUAYI, HYS55, HYS60, HYE81, HYE90, 1/6 hp, 1/5 hp, 1/4 hp, LBP, R134a, R600a

mbsmgroup-files-2026-01-22_031414-mbsmpro mbsmpro

Focus Keyphrase

HUAYI Refrigerator Compressor Technical Specifications HYS45 HYS55 HYS60 HYS69 HYE81 HYE90 HY113 HY131 HY153 LBP R134a R600a

SEO Title

Mbsmpro, Compressor, HUAYI, HYS55, HYS60, HYE81, HYE90, 1/6 hp, 1/5 hp, 1/4 hp, LBP, R134a, R600a

Meta Description

Professional technical guide for HUAYI compressors. Detailed data for HYS and HYE series, including HP, cooling capacity, and equivalents. Expert analysis for HVAC technicians.

Slug

huayi-compressor-hys-hye-series-technical-data-replacement

Tags

Mbsmgroup, Mbsm.pro, mbsmpro.com, mbsm, HUAYI, HYS45, HYS55, HYS60, HYS69, HYE81, HYE90, HY113, HY131, HY153, ACC GVY57AA, Secop TLY8.7KK, Embraco EMT6170Z, Danfoss TLS6F, Samsung SD162, LG MA57LAJG, Panasonic QB66C13GAX5, Cubigel GL60AA, Donper LU111CY

Excerpt

The HUAYI compressor lineup, featuring the HYS and HYE series, is a cornerstone in modern domestic refrigeration. These Low Back Pressure units utilize R134a and R600a refrigerants to provide efficient cooling for household freezers and refrigerators. Designed for durability and high performance, they offer professional-grade solutions for various cooling capacities from 1/10 to 1/3 horsepower.


Technical Data Sheet: HUAYI Compressor Series

Feature Detailed Specification
Model HUAYI HYS/HYE Series (e.g., HYS60, HYE90)
Utilisation (mbp/hbp/lbp) LBP (Low Back Pressure)
Domaine (Freezing/Cooling) Freezing / Deep Cooling
Oil Type and Quantity POE/Mineral (160ml – 220ml depending on model)
Horsepower (HP) 1/10 HP to 1/3 HP
Refrigerant Type R134a (HYS) / R600a (HYE)
Power Supply 1Ph / 220-240V / 50Hz
Cooling Capacity BTU 380 – 800 BTU/h (Range across models)
Motor Type RSIR / RSCR
Displacement 4.5 cm³ to 15.3 cm³
Winding Material High-Quality Copper
Pression Charge 0.5 – 1.2 Bar (Suction Side)
Capillary 0.026″ to 0.031″ (Application dependent)
Refrigerator Models Samsung, LG, Whirlpool, Beko, and Generic brands
Temperature Function -35°C to -10°C
With Fan or No Static Cooling (No fan required for most)
Commercial or No Domestic / Light Commercial
Amperage in Function 0.6A – 1.3A
LRA (Locked Rotor Amps) 5.0A – 9.0A
Type of Relay PTC Start Relay
Capacitor and Value Optional (3µF – 5µF for RSCR models)

5 Compressor Replacements (Same Gas – R134a/R600a):

  1. ACC / Secop GVY57AA (R134a)
  2. Embraco EMT6170Z (R134a)
  3. Danfoss TLS6F (R134a)
  4. Panasonic QB66C13GAX5 (R600a)
  5. Jiaxipera N1113Y (R600a)

5 Compressor Replacements (Alternative Gas Equivalents):

  1. Secop TLY8.7KK.3 (Transition to R600a)
  2. Embraco EMX46CLC (Transition to R600a)
  3. Donper LU111CY (High efficiency R600a)
  4. Cubigel GL60AA (Standard R134a)
  5. Samsung SD162 (Reliable R134a alternative)

Technical Analysis: The Engineering Behind HUAYI Refrigeration

In the field of appliance repair and HVAC engineering, HUAYI has become a household name—not just for their availability, but for their consistent performance in tropical climates. Whether you are dealing with the HYS series (R134a) or the newer, eco-friendly HYE series (R600a), understanding the internal mechanics is key to a long-lasting repair.

Comparison: R134a vs. R600a Performance

While the HYS60 (1/5 HP) is a classic workhorse, the industry shift toward HYE90 (1/4 HP R600a) reflects a move toward thermodynamic efficiency. R600a (Isobutane) operates at lower pressures, which reduces the load on the compressor valves and extends the lifespan of the motor. However, from an engineering standpoint, R600a requires a larger displacement (9.0 cm³ vs 6.0 cm³) to achieve similar cooling capacity to its R134a counterparts.

Winding and Electrical Configuration

As an expert who has handled these units on the bench, I can confirm that the HUAYI motor design usually follows a RSIR (Resistive Start-Inductive Run) or RSCR (Resistive Start-Capacitive Run) configuration.

Wiring Schema for HUAYI PTC Relay:

  1. Common (C): Top Pin (Connected to Overload Protector).
  2. Main/Run (R): Right Bottom Pin.
  3. Start (S): Left Bottom Pin. For RSCR models, the capacitor is bridged between the Start and Run pins to improve torque and energy consumption.

Engineering Values: Comparison Table

Model HP Displacement (cm³) Capacity (W) Efficiency (W/W)
HYS45 1/8 4.5 110 1.15
HYS55 1/6 5.5 135 1.20
HYE81 1/5+ 8.1 145 1.45
HYE131 1/3 13.1 225 1.38

Pro Tips for Field Installation

  • Notice: When replacing an R134a compressor with an R600a unit, you must change the filter drier and perform a nitrogen purge. R600a is highly sensitive to residual moisture.
  • Benefit: Using the HYE series (RSCR) with a dedicated run capacitor can reduce electricity consumption by up to 15% compared to standard RSIR units.
  • Safety: Always verify the LRA (Locked Rotor Amps). If the compressor fails to start under load, check the PTC relay resistance. A standard HUAYI PTC should read between 15 and 30 Ohms at room temperature.

Final Verdict

The HUAYI series offers a versatile range for the artisan. While the HYS models are robust and “forgiving” regarding slightly imperfect vacuums, the HYE series is the future of high-efficiency domestic freezing. When in doubt, always size your compressor based on the Displacement (cm³) and Cooling Capacity (Watts) at -23.3°C to ensure the evaporator remains fully flooded without liquid slugging returning to the compressor.


Modèle Réf App. Puissance Capacité de refroidissement Puissance d’entrée COP Type de fil
Hp W/hr (W/W)
Référence: CMA042LHEG Référence: R134a LBP 220V/50Hz 1/8HP 107W 79W 1.31  Fil d’Al-
Référence: CMA053LHEG Référence: R134a LBP 220V/50Hz 1/6HP 150W 102W 1.48  Fil d’Al-
Référence: CMA057LHEG Référence: R134a LBP 220V/50Hz 1/5HP 163W 115W 1.42  Fil d’Al-
Référence: CMA069LHEM Référence: R134a LBP 220V/50Hz 1/4HP 195W 128W 1.52  Fil d’Al-
Référence: CMA075LAEM Référence: R134a LBP 220V/50Hz 1/4HP + 215W 130W 1.68  Fil de cuivre
LX95LHBM Référence: R134a LBP 220V/50Hz 1/3HP 267W 173W 1.25  Fil d’Al-
LX110LAJM Référence: R134a LBP 220V/50Hz 1/2HP 323W 232W 1.39  Fil de cuivre
Référence: CSB057NJEG Référence: R600a LBP 220V/50Hz 1/10HP 100W 77W 1.30  Fil d’Al-
Référence: CSB069NJEG Référence: R600a LBP 220V/50Hz 1/8HP 126W 90W 1.40  Fil d’Al-
Référence: CSB075NJEG Référence: R600a LBP 220V/50Hz 1/6HP 139W 102W 1.36  Fil d’Al-
Pièces connexes CMA082NHEM Référence: R600a LBP 220V/50Hz 1/5HP 148W 81W 1.84  Fil d’Al-
Référence: CMA098NHEM Référence: R600a LBP 220V/50Hz 1/4HP 181W 98W 1.85  Fil d’Al-
Référence: CMA110NJEM Référence: R600a LBP 220V/50Hz 1/4HP 194W 122W 1.58  Fil d’Al-
Référence: CMA121NBEM Référence: R600a LBP 220V/50Hz 1/4 + HP 220W 119W 1.85  Fil de cuivre
mbsmgroup-files-2026-01-22_031436-mbsmpro mbsmpro